• 제목/요약/키워드: 지하도 상가

검색결과 117건 처리시간 0.028초

지하도 상가 냉난방.환기 시스템의 난방운전 특성 연구 (An Experimental Study on the Heating Characteristics of HVAC Systems for Shopping Center in Underground Passage)

  • 이홍철;황인주;김태형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2989-2994
    • /
    • 2008
  • The shopping center in underground passage for efficient space utilization is increased in urban area. This study describes operation characteristics of HVAC systems with ventilation and individual heating and cooling unit for shopping center in underground passage. In order to compare energy saving, thermal environment and installation space, etc., an integrated simulator with heat production and distribution system was designed and constructed. Energy delivery efficiency is improved over 20%, and energy saving of the hybrid system is calculated as over 30% compared to conventional all air type in the case of heating. And also the results showed that humidity decreased about $5{\sim}6%$, also characteristics of thermal control is improved over 34%.

  • PDF

지하상가 출입구 방풍문 설치에 따른 피난안전해석 (Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade)

  • 최영상;전흥균;추홍록
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-10
    • /
    • 2009
  • 지하상가는 특성상 출입구에 문을 설치할 경우 피난안전에 미치는 영향을 더 면밀하게 분석할 필요가 있다. 본 연구에서는 이미 사용 중에 있는 지하상가의 출입구 중 일부 출입구에 문을 설치하는 경우에 대해 CFAST로 화재시뮬레이션을 수행하고 그 결과를 building EXODUS 피난시뮬레이션의 위험인자로 활용하여 화재위험을 고려한 피난해석을 하였다. 지하상가의 6개 출입구 중에 2곳에 문을 설치할 경우에 대해 화재피난과 일반피난으로 나누어 1,088명에 대해 피난해석을 하였다. 일반피난의 경우는 문 설치에 따른 영향이 거의 없었으나 화재피난의 경우는 문 설치로 인해 약 110초의 피난지연이 발생하였다. 또 자동문이 설치된 경우는 자동문이 열리지 않을 때가 문 설치 전보다 670초 피난지연이 발생하였다. 따라서 자동문은 화재감지기와 연동하여 개방된 상태로 정지하도록 설치되어야 하고, 문을 설치할 경우 피난안전을 위해 피난유도표시를 보강하는 것도 필요하다.

서울시 일부 지하공간에서의 실내공기질 평가에 관한 연구 (A Study on Assessment of IAQ(Indoor Air Quality) for Underground Environments in Seoul)

  • 정진원;김윤신;윤동원;권성안
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 춘계학술대회 논문집
    • /
    • pp.304-306
    • /
    • 2000
  • 오늘날 경제적 생활 환경의 개선으로 인하여 현대인의 생활에 많은 변화를 가져오고 있다 제한된 공간에서 인간 활동은 지하생활공간이라는 새로운 활동영역을 창출하였고, 이에 따라 실내에서의 거주 시간은 더욱 증가하고 있다. 지하생활공간이라는 용어가 일반인들에게는 다소 생소하게 받아들여질 수 있지만 여기서 말하는 지하생활공간이라 함은 불특정 다수인이 이용하는 지하철, 지하상가, 지하주차장, 지하 보·차도, 지하터널 등을 말하며 개인의 생활 양식에 따라 단시간 이용하거나 또는 생활터전으로 장시간 거주할 수 있는 공간이라고 할 수 있다. (중략)

  • PDF

지하상가 쇼핑환경 개선방향에 관한 연구 - 지하철과 연계된 직선형 지하상가를 중심으로 - (A Remodeling Concept for the Underground Shopping Mall in Seoul - Focusing on the Linear Shopping Mall linked to Subway Lines -)

  • 서경욱
    • 한국실내디자인학회논문집
    • /
    • 제19권2호
    • /
    • pp.15-23
    • /
    • 2010
  • First appeared in the 1970s, the underground shopping mall has been spreading across the country, and there reportedly exist 77 malls in the 2010. After over 30 decades operation, many underground shopping malls are now under the planning phase for renovation in many cities. This study considers the renovation issue of the underground shopping mall in the perspective of spatial re-configuration. A case is taken from Kangnam TerminalUnderground Shopping Mall in Seoul for detailed observation and suggestion. The monotonous and confusingspatial layout of the existing mall is investigated by observation methods. Based on the observation, a modifiedplan is suggested and evaluated by means of computer simulation program, Depth Map. The program mainly deals with visual network analysis in order to quantify the optical exposure in a given space. It is argued in this paper that the enhanced visual connectedness could affect the pedestrian performance positively in the shopping mall, and this leads to an easy and quick access to each shops in users' stand point. It is thought that this configurational solution for the remodelling of a specific case would be an effective reference for other malls in the country which are facing the similar problems.

지하공간시설에서의 피난안전대책을 위한 시뮬레이션 해석 (Simulation analysis for evacuation safety countermeasure in underground facilities)

  • 김봉찬;김세종;김경구;이주희;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.100-105
    • /
    • 2011
  • 본 연구에서는 재실자의 밀도가 높은 지하상가는 공간의 특성상 화재가 발생할 경우 다량의 유독가스의 발생 및 연기의 이동경로와 인간의 피난경로 일치로 인하여 피난안전에 큰 위험성이 있다고 사료된다. 이에 지하철 역사와 연결되어 있는 지하상가를 선정 후, 일본 피난안전성평가수법과 FDS(Fire Dynamic Simulator) 및 SIMULEX를 이용하여 비교 분석을 하였으며, 그 결과, 화재발생 후 6분이 경과 시 위험한 것으로 판단되었다. 그에 대한 대책으로 자연 배연구를 설치하여 시뮬레이션 수행을 한 결과 가시도확보 및 각 출구에서의 온도가 하강하는 것을 확인할 수 있었다.

  • PDF