• 제목/요약/키워드: 지하공간 화재

검색결과 235건 처리시간 0.021초

도로터널내 화재 발생시 매연 제거를 위한 모델 해석 (A Model-Analysis for Removal of Fire Fumes in a Road Tunnel during a Fire Disaster)

  • 윤성욱;이희근
    • 터널과지하공간
    • /
    • 제7권2호
    • /
    • pp.100-107
    • /
    • 1997
  • In case of a fire outbreak in a uni-directional road tunnel, the flow of traffic immediately behind the fire disaster will be stalled all the way back to the entrance of the tunnel. Furthermore, when the vehicle passengers try to flee away from the fire toward the entrance of the tunnel, the extremely hot fume that propagates in the same direction will be fatal to the multitudes evacuating, but may also cause damage to the ventilation equipments and the vehicles, compounding the evacuation process. This paper will present the 3-dimensional modelling analysis of the preventive measures of such a fume propagation in the same direction as the evacuating passengers. For the analysis, the fire hazard was assumed to be a perfect combustion of methane gas injected through the 1 m X 2 m nozzle in the middle of the tunnel, and the product of $CO_2$ as the indicator of the fume propagation. From the research results, when the fire hazard occurred in middle of the 400 m road tunnel, the air density decreased around the fire point, and the maximum temperatures were 996 K and 499 K at 210 m and 350 m locations, respectively, 60 seconds after fire disaster occurred, when the fumes were driven out only towards the exit-direction of the tunnel. By tracing the increase of $CO_2$ level over 1% mole fraction, the minimum longitudinal ventilation velocity was found to be 2.40 m/sec. Furthermore, through Analysis of the temperature distribution graphs, and observation of the cross-sectional distribution of $CO_2$ over 1% mole fraction, it was found that the fume did not mix with the air, but rather moved far in a laminar flow towards exit of the tunnel.

  • PDF

일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험 (The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster)

  • 유영일;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF

폭발방지를 고려한 LPG 저장탱크 최적설계 (Optimization of Explosion Prevention for LPG Storage Tanks)

  • 임사환;허용정;손석우;임재기;이종락
    • 대한기계학회논문집A
    • /
    • 제34권7호
    • /
    • pp.897-903
    • /
    • 2010
  • 자동차 연료로 가스를 사용하는 것은 '삶의 질' 향상을 넘어 '생존'의 문제로 환경보존과 경제발전을 조화롭게 추구하는 '지속가능한 발전'이란 새로운 패러다임에 부흥하고 있다. 하지만 가스사용이 늘어나면서 폭발과 화재에 의한 인명피해가 해마다 발생하고 있으며, 대규모 저장시설에서의 가스 사고는 사회적으로 심각한 문제를 야기하고 있다. 따라서 본 논문에서는 지하 격납 저장탱크에서의 폭발발생을 최소화하기 위하여 한정된 내용적과 화염에 노출되는 표면적을 최소로 하는 폭발방지를 고려한 최적의 저장탱크를 설계하였다. 본 연구를 통하여 최적조건의 저장탱크를 설계한 결과, 20ton 저장탱크는 직경 3m, 길이 4.83m일 때 지하 격납 공간이 최소가 되었으며, 화염에 노출되는 표면적은 기존의 저장탱크에 비하여 89.4%로 줄어들어 안전성이 향상되었다.

역 원근변환 기법을 이용한 터널 영상유고시스템의 원거리 감지 성능 향상에 관한 연구 (A study for improvement of far-distance performance of a tunnel accident detection system by using an inverse perspective transformation)

  • 이규범;신휴성
    • 한국터널지하공간학회 논문집
    • /
    • 제24권3호
    • /
    • pp.247-262
    • /
    • 2022
  • 국내 200 m 이상 연장의 터널에서는 CCTV 설치가 의무화되어 있으며, 터널 내 돌발 상황을 자동으로 인지한 다음 터널 관리자에게 알릴 수 있는 터널 영상유고시스템의 운영이 권고된다. 여기서 터널 내 설치된 CCTV는 터널 구조물의 공간적인 한계로 인해 낮은 높이로 설치된다. 이에 따라 이동차량과 매우 인접하므로, 이동차량과 CCTV와의 거리에 따른 원근현상이 매우 심하다. 이로 인해, 기존 터널 영상유고시스템은 터널 CCTV로부터 멀리 떨어질수록 차량의 정차 및 역주행, 보행자 출현 및 화재 발생과 같은 터널 내 유고상황을 인지하기 매우 어려우며, 100 m 이상의 거리에서는 높은 유고상황 인지 성능을 기대하기 어려운 것으로 알려져 있다. 이 문제를 해결하기 위해 관심영역 설정 및 역 원근변환(Inverse perspective transform)을 도입하였으며, 이 과정을 통해 얻은 변환영상은 먼 거리에 있는 객체의 크기가 확대된다. 이에 따라 거리에 따라 객체의 크기가 비교적 일정하게 유지되므로, 거리에 따른 객체 인식 성능과 영상에서 보이는 차량의 이동속도 또한 일관성을 유지할 수 있다. 이를 증명하기 위해 본 논문에서는 터널 CCTV의 원본영상과 변환영상을 바탕으로 동일한 조건을 가지는 데이터셋을 각각 제작 및 구성하였으며, 영상 내 차량의 실제 위치의 변화에 따른 겉보기 속도와 객체 크기를 비교하였다. 그 다음 딥러닝 객체인식 모델의 학습 및 추론을 통해 각 영상 데이터셋에 대한 거리에 따른 객체인식 성능을 비교하였다. 결과적으로 변환영상을 사용한 모델은 200 m 이상의 거리에서도 객체인식 성능과 이동차량의 유고상황 인지 성능을 확보할 수 있음을 보였다.

QRA를 이용한 철도터널 방재 안전성 평가 (Estimation of Safety in Railway Tunnel by Using Quantitative Risk Assessment)

  • 김도식;김도형;김우성;이두화;이호석
    • 터널과지하공간
    • /
    • 제16권5호
    • /
    • pp.357-367
    • /
    • 2006
  • 최근 신설철도가 계획되거나 선형개량공사가 증가함에 따라 터널 구조물이 장대화되고 있다. 장대터널에서 터널내 열차화재 등이 발생하는 경우 대형사고를 초래할 수 있으므로 터널 방재에 대한 관심이 증가하고 있으며, 이에 따른 터널 방재기준도 더욱 강화되고 있는 실정이다. 따라서 터널계획시 방재기준을 만족하면서 위험도를 최소화할 수 있는 최적 방재시설물 계획이 요구되고 있다. 이와 같이 합리적인 장대터널 방재 설계를 위해서는 열차사고 통계분석 및 피난시뮬레이션을 기초로 한 보다 객관적이며, 정량적인 평가가 필요하다 할 수 있으며, 이를 위해서 본 연구에서는 정량적 위험도 분석기법인 QRA (Quantitative Risk Assessment)를 철도터널에서의 방재설계에 적용하고자 하였다. 대상터널은 연장 약 4.1 km의 산악터널(사례 I)과 연장 약 3.6 km인 도시지역터널(사례 II)로서 두 터널 모두 철도터널 관련 방재기준보다 향상된 터널방재성능이 요구되어, 도시지역 안전기준에 만족하는 합리적인 터널내 방재구조물 계획을 수립하기 위하여 정량적 위험도분석을 실시하였다. 장대터널에서의 갱외탈출로 개념의 사갱 및 수직구 계획을 수립하기 위하여 각각의 경우에 대한 QRA를 실시하고, 장대터널의 방재 안정성을 평가함으로써 실행 가능한 합리적인 수준의 터널 방재설계를 수행하고자 하였다.