• 제목/요약/키워드: 지중송전계통

검색결과 82건 처리시간 0.021초

지중송전계통의 접지특성분석에 관한 연구 (A Study on the Grounding Characteristics of Underground Transmission Power Canble Systems)

  • 정채균;홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.482-484
    • /
    • 2001
  • Earth resistivity and changing of grounding electrode's shape are very important factor to reduce grounding resistance. Earth resistivity has different values according to property of soil and is effected by temperature, climate, and environment. This Paper describes the effect of the grounding resistance according to the grounding type such as driven rod, counterpoise grounding and mesh grounding. And also grounding resistance values with earth resistivity and shape of grounding electrode were represented in this paper.

  • PDF

지중송전계통에서 시스유기전압 및 CCPU 동작 특성 해석 (Analysis of Sheath Induced Voltage and CCPU Operating Characteristic in Underground Transmission Cable)

  • 진혜영;이종범;김영;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2001
  • This paper describes sheath induced voltage and operating characteristic of cable cover protection unit(CCPU) in underground transmission cable. Real cable system operating by 154kV XLPE cable was modelled for simulation. Sheath induced voltage and operating characteristic of CCPU were analyzed. In particular, sheath induced voltage was analyzed in case of individual grounding and common grounding, respectively, and operating characteristics of CCPU were compared each other.

  • PDF

SWT를 이용한 지중송전계통의 고장검출 및 고장점 추정 (Fault Detection and Location using SWT on Underground Power Cable System)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.51-53
    • /
    • 2004
  • In this paper, we are going to propose the new algorithms to detect, classify, discriminate the transient and the reflected signal from noise and thus discriminate the fault section and locale the fault accurately on underground power cable system. Actually, at this system, it's very difficult to discriminate the transient because of the reflected signal including many noises. Therefore, how to solve the noise interference is a big problem. In this paper, authors present a solution based on multiple scales correlation of the transient using stationary wavelet transform. It's simple, quick and straightforward. For applying all algorithms, we just use the signal captured in single end.

  • PDF

Multiscale Correlation을 이용한 지중송전계통 고장점 추정에 관한 연구 (A Study on the Fault Location Using Multiscale Correlation in Underground Power Cable Systems)

  • 정채균;이종범;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.557-559
    • /
    • 2004
  • The study of applying wavelet transform in power cable system fault location has been recognized by many researchers and investigated. For performance of fault location, the fault generated transients can be captured at one end of the cable or both ends. Between two approaches, single-ended approach is less expensive and more reliable as it doesn't need communication link between the ends of the cable. So, we performs the approach based on the one. In this paper, we are going to introduce a new algorithm to discriminate the transient and the reflected signal using wavelet coefficient. For wavelet transform, the stationary wavelet transform(SWT) is applied instead of conventional DWT because SWT has redundancy properties which is more useful in noisy signal processing.

  • PDF

초전도케이블의 장기 부하변동시험 및 성능평가 (Long-term load cycle test of the HTS cable system)

  • 임지현;손송호;임성우;성태현;황시돌;최하옥;양형석;마용호;류경우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.300-300
    • /
    • 2008
  • 우리나라의 전기에너지 수요가 지속적으로 증가함에 따라 새로운 송배전 선로의 구축이 필요하다. 하지만 현재 도심지의 전력구에는 더 이상의 지중선의 증설은 불가능하며 가공선 설치의 경우 환경 민원의 부담을 떠안게 된다. 그래서 기존 동도체의 회선당 송전 한계를 극복하고 대용량 송전 및 손실을 크게 줄일 수 있는 초전도 케이블의 연구가 세계적으로 활발히 진행되고 있다. 한국전력 전력연구원은 신 전력시스템으로서의 22.9 kV급 초전도케이블 시스템을 고창전력시험센터에 설치하고 운영 및 유지 보수 과정을 통하여 실제 계통 적용을 위한 최적 운전조건을 연구하고 있다. 이 논문에서는 실제 부하 상황을 모의하기 위하여 초전도케이블의 장기 부하변동 시험에 따른 케이블 송전 능력 확인 및 냉각시스템의 반응성을 살펴보고 부하변동 시험 후 초전도케이블 도체 열화 여부를 확인하기 위하여 직류 임계전류를 측정하였다. 그 결과 부하변동 시험 전의 임계전류 값과의 변화율이 삼상 모두 ${\pm}1$% 내외로서 오차범위를 벗어나지 않으므로 건전한 것으로 판단되었다.

  • PDF

지중송전계통에서 OF 및 XLPE 케이블 혼용 연계 운용의 효용성 평가 (Effectiveness Evaluation on Combined Connection Operation of OF and XLPE Cable)

  • 채직병;이종범
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.857-863
    • /
    • 2015
  • OF cable with excellent reliability and economic efficiency, has been used as the main cable of underground transmission in Korea. However, as XLPE cable is excellent in view points such as reduction of loss, convenience on the construction/operation, and manufacturing technology, it has been replaced as instead of OF cable. Also, when the aging occurs in some sections of OF cable, the section is replaced as XLPE cable without changing of whole cable line. However, there are some differences like electrical constants between both types of cables. Therefore if underground transmission system will be operated as combined connection composited of both cables, it should be proved that overvoltage is stable in steady and transient state. This paper describes the effectiveness of connection operation in combined OF and XLPE cable. For the evaluation of effectiveness, some important analysis such as sheath component voltage, lightning and switching overvoltage, single line-to-ground fault are carried out in steady and transient state. EMTP/ATPDraw is used for modeling and analysis of system.

지중송전계통에서 저감장치를 이용한 시스 순환전류 저감방안에 관한 연구 (A Study on the Reduction Methods of Sheath Circulating Current using the Reduction Equipment in Underground Transmission Systems)

  • 강지원;양해원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.474-481
    • /
    • 2002
  • Sheath circulating current is increased in the change of sheath mutual impedance which is caused by unbalanced cable system, and different section length between joint boxes. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Accordingly, actual schemes to reduce excessive sheath circulating current are urgently required for installed cable system as well as newly-installing cable systems. This paper describes the relation analysis of sheath circulating current and burying types. And also, various schemes to reduce excessive circulating current using EMTP/ATPDraw and applicable schemes are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction schemes can be effectively applied to reduce the excessive sheath circulating current with the minimized electrical problems. And reduction effect is Proved with sheath circulating current reduction equipment.

지중송전계통에서 절연접속함 위치 및 접지방식 변경의 효용성 평가 (Effectiveness Evaluation According to Change of IJ Joint Box Location and Grounding System in Underground Transmission System)

  • 고광만;이종범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.247-253
    • /
    • 2015
  • Dielectric breakdown accidents have been mainly occurred in the vicinity of service entrance section in underground power transmission systems. One cause among them is due to the excessive component value of sheath located around service entrance of cable. In this paper, as one of the alternative to prevent these accidents, the change of cross bond grounding system and the location change of IJ(Insulation Joint) are suggested. Also, to evaluate effectiveness of this changing system, circulating current and induced voltage of sheath were analyzed in steady and transient state. By comparison of the analytical results for the several possible changing systems, a grounding system and location of IJ which has the smallest sheath component values is proposed. In this paper, analysis to evaluate the proposed system is carried out by EMTP/ATPDraw. It can be used as a valuable operational material to prevent accident of the service entrance section in underground power transmission system.

퍼지추론시스템 기반 지중송전계통 보호용 거리계전 알고리즘 개발 (Fuzzy Inference System Based Distance Relay Algorithm Development for Protecting an Underground Power Cable Systems)

  • 정채균;오성권;박건준;이재규;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.172-178
    • /
    • 2008
  • If the fault occurs on the underground power cable systems, the fault current on the sheath has an influence on all sections of cable because it's returned through earth at the directly grounded point and operation point of SVL(Sheath Voltage Limiter) on each insulated joint box. Therefore, the earth resistance and the operation of SVL have an effect on the zero-sequence current, and then the impedance between relaying point and fault point is increased. That causes the overreach of distance relay. For these reasons, the distance relay algorithm for protecting an underground power cable systems hasn't been developed till now. In this paper, new distance relay algorithm is developed for protecting a underground power cable system using fuzzy inference system which is the one of ACI(Advanced Computational Intelligence) techniques. This algorithm is verified by EMTP simulation of real power cable system, and proves to effectively advance the errors

지중송전계통의 시스순환전류 저감에 관한 연구 (A Study on the Reduction of Sheath Circulating Current in Underground Transmission Systems)

  • 정채균;홍동석;이종범;강지원;유철환;강원탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.29-33
    • /
    • 2001
  • Sheath circulating current results from the change of sheath mutual impedance which is caused by unbalanced cable system, and different section length between joint boxes. If circulating over current flows in sheath, it produces much sheath loss which reduces the transmission capacity. And also such large sheath current influences severely on the operator. Recently, large sheath circulating current was partially measured in underground cable system of KEPCO. Accordingly, actual schemes to reduce sheath circulating over current is urgently required for installed cable system as well as newly-constructing cable system. This paper describes the analysis of sheath circulating current and various schemes to reduce the large circulating current in case of operating cable system using EMTP/ATPDraw. And also, possible schemes are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction schemes can be effectively applied to reduce the large sheath circulating over current with the minimized electrical problems.

  • PDF