• Title/Summary/Keyword: 지연제

Search Result 1,083, Processing Time 0.033 seconds

A Study on Properties of Retarder via Tabletting Method (정제화 방법을 이용한 응결 지연제의 특성에 관한 연구)

  • Ryou, Jae-Suk;Yang, Neung-Won;Lee, Yong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.201-207
    • /
    • 2013
  • When hot weather concrete is utilized, the cooling methods of cooling pipe, liquid nitrogen, ice, etc., are used to prevent the poor consistency and cold joint due to high temperature. These methods, however, spike the production cost and energy consumption, and make quality control difficult. Among these methods is one that involves the use of a retarder. Although economical, retarder is caused difficulty of retarded hardening and setting time control due to inaccurate weighing and poor working condition. Therefore, how to make a tablet for hot weather concrete, as with the existing pharmacy and foods, is discussed in this study, including the following items: mortar setting time, flow test by elapsed time, physical and mechanical properties of concrete. As a result, gluconic acid is superior to lignosulfonic acid and the possibility of using them for such purpose without quality degradation was confirmed in this study, when retarder is tabletting.

Experimental Studies of a Time-delayed Controller for Balancing Control of a Two-wheel Mobile Robot (이륜 이동로봇의 균형 제어를 위한 시간지연 제어기의 실험 연구)

  • Cho, Sung Taek;Jung, Seul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2016
  • This paper presents balancing control of a two-wheel mobile robot (TWMR). TWMR is aimed to maintain balance while moving. Although TWMR can be controlled by linear controllers such as PD controller, time-delayed controller is employed for robustness. Performances of PD controllers and time-delayed controllers are compared. Especially, experimental studies on different acceleration estimation for the time-delayed controller are conducted. Performances by different acceleration estimations of the balancing angle, of the position, and of both angle and position are compared empirically.

A Study on change in thermal properties and chemical structure of Zr-Ni delay system by aging (노화에 따른 Zr-Ni계 지연관의 열 특성 및 화학적 구조 변화에 관한 연구)

  • Park, Byung Chan;Chang, Il Ho;Kim, Sun Tae;Hwang, Taek Sung;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.285-292
    • /
    • 2009
  • It has been observed that, after long term storage, some ammunitions are misfired by tamping (combustionstopping) due to aging of the chemicals loaded in the ammunitions. Used in ammunitions are percussion powder which provides the initial energy, igniter which ignites the percussion powder, and a delay system that delays the combustion for a period of time. The percussion powder is loaded first, followed by the igniter and then the delay system, and the ammunitions explode by the energy being transferred in the same order. Tamping occurs by combustion-stopping of the igniter or insufficient energy transfer from the igniter to the delay system or the combustion-stopping of the delay system, which are suspected to be caused by low purity of the components, inappropriate mixing ratio, size distribution of particulate components, type of the binder, blending method, hydrolysis by the humidity penetrated during the long term storage, and chemical changes of the components by high temperature. Goal of this study is to find the causes of the combustion-stopping of the igniter and the delay system of the ammunitions after long term storage. In this study, a method was developed for testing of the combustion-stopping, and the size distributions of the particulate components were analyzed with field-flow fractionation (FFF), and then the mechanism of chemical change during long term storage was investigated by thermal analysis (differential scanning calorimetry), XRD (X-ray diffractometry), and XPS (X-ray photoelectron spectroscopy). For the ignition system, M (metal)-O (oxygen) and M-OH peaks were observed at the oxygen's 1s position in the XPS spectrum. It was also found by XRD that $Fe_3O_4$ was produced. Thus it can be concluded that the combustion-stopping is caused by reduction in energy due to oxidation of the igniter.

Surface Properties of Exposed-Aggregate Concrete Depending on Retarder and Water Jet Washing Timing (지연제 살포량과 물씻기 시간이 골재노출 콘크리트의 표면성상에 미치는 영향)

  • Park, Jun Hui;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.169-175
    • /
    • 2015
  • Recently, a stone is preferred as a cladding materials because of its outstanding durability and luxurious character. However, because of running out of natural resources and restriction of production, it is expected that difficulty of stable supply, and thus alternative cladding materials for concrete wall is needed. Therefore, in this research, as an alternative cladding materials, exposed-aggregate concrete is studied using saccharin based retarder. For evaluating factors, changing water-to-cement ratio, dosages of saccharin-based retarder, and timing of water jet washing were tested on the surface properties of exposed-aggregate concrete. As a result, the most favorable surface performance was obtained at 0.75 day after the placing in 25% of water-to-cement ratio, and at one day after the placing in 35 and 55% of water-to-cement ratio, 1.5 day after the placing in 65% of water-to-cement ratio with $24m{\ell}/m^2$ of retarder application.

The Effects of Slide-Covered of Slide-Covered Contemporary Charging Automated External Defibrillator on Rapidity and Convenience of Defibrillation (슬라이드 커버 동시충전 자동심장충격기가 제세동의 신속성과 편의성에 미치는 효과)

  • Park, Si-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.325-333
    • /
    • 2020
  • This study compares the rapidity and subjective convenience of T-AED and SC-AED for health care providers and the general public. Subjects were randomly allocated to T-AED (n=77) and SC-AED (n=79) groups. Each group conducted defibrillation, with subsequent measurement of the rapidity of defibrillation in peri-shock pause, pre-shock pause, hesitation pause, and post-shock pause. Defibrillation and chest compression delay times for both equipment were analyzed by t-test. On conclusion of the experiment, subjects answered a questionnaire on the subjective convenience of defibrillation, as measured for confidence, convenience, and clear decision. Comparisons of subjective convenience analyzed by t-test revealed significantly shortened peri-shock pause (11.22s), pre-shock pause (11.04s), and hesitation pause (2.15s) in the SC-AED group, as compared to the T-AED group (p<0.001). However, no significant differences were observed for post-shock pause values. Comparing subjective convenience, confidence (T-AED: 7.62±1.25VAS vs. SC-AED: 7.80±0.98VAS, p=0.358) was not significant, whereas convenience (T-AED: 7.05±1.36VAS vs. SC-AED: 8.95±0.89VAS, p<0.001) and clear decision (T-AED: 6.58±1.73VAS vs. SC-AED: 9.08±0.98VAS, p=0.001) showed statistically significant differences. Our results indicate that compared to T-AED, SC-AED has significantly shortened pauses. Moreover, it is more convenient for the user, and significantly aids in clear decisions.

Tooth Agenesis and Delay in Patients with Agenesis of Mandibular Second Premolars (하악 제2소구치 결손과 연관된 치아 결손 및 발육지연)

  • Park, Minji;Kim, Seong-Oh;Song, Je Seon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.484-491
    • /
    • 2018
  • Tooth agenesis is a common human dental anomaly and the agenesis of mandibular second premolars has been proven to be the most frequently observed. The aim of this study is to investigate tooth agenesis and delayed tooth development in patients with agenesis of mandibular second premolars. This study reviewed 9 to 15 year-old patients with agenesis of mandibular second premolars who visited the department of pediatric dentistry of Yonsei University Dental Hospital and took panoramic radiographs from January 2014 to December 2016. On panoramic radiographs, agenesis of teeth was observed and developmental delay of teeth was evaluated by the Nolla method. Among 125 patients with agenesis of mandibular second premolars, 58 patients (46.4%) showed agenesis of other teeth and 38 patients (30.4%) showed delayed tooth development. In this study, patients with agenesis of mandibular second premolars were more likely to have tooth agenesis or delayed eruption of other teeth.

Adhesion Strength Properties of Matrix Using Magnesia Accroding to Potassium Phosphate Addition Ratio (산화마그네슘을 활용한 경화체의 지연제 첨가율에 따른 접착강도 특성)

  • Kim, Tae-Hyun;Sin, Jin-Hyun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.34-35
    • /
    • 2016
  • Most of the construction adhesive may contain harmful component to the human body with an organic adhesive. In addition, when the adhesive caused hydroquinone, alkyl benzophenone, etc, also it raises the skin diseases to workers. Therefore, the inorganic adhesive development is necessary. This study was a study to know adhesive strength properties that adhesive using a magnesium oxide according to the addition ratio of the retarder. It has experiments to two types of magnesium oxide and type and ratio of retarder differently.

  • PDF

Drug Release by Poly(DL-lactide) Coated Chitosan Derivatives Matrices (Poly(DL-lactide)로 피막된 키토산 유도체 매트릭스에서의 약물방출)

  • 차월석;나재운이동병
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.461-467
    • /
    • 1995
  • In this study, the release experiments of drug were operated in the phosphate buffer solutions of pH 7.4 and pH 1.2 by using drug carriers(chitosan, chitosan hydrochloride, and sulfonated chitosan)coated by poly(DL-lactide) with prednisolone for delivery drug. The release time of drug was more delayed in pH 7.4 than in pH 1.2. The release time of according to the kinds of drug carrier was delayed in the order of chitosan, sulfonated chitosan, and chitosan hydrochloride. In short, the formulation allows biodegradable coated monolithic polymetic matrices to suppress the burst effect of the drug release mechanism, which led to the sustained release pattern.

  • PDF

특집 - 당분 흡수 억제제

  • O, Tae-Geun
    • The Monthly Diabetes
    • /
    • s.222
    • /
    • pp.11-12
    • /
    • 2008
  • 당뇨병환자의 식후 고혈당을 조절하고자 가장 많이 사용되고 있는 약제가 "알파글루코시다제 억제제"라는 당분 흡수 억제제이다. 이는 복합탄수화물의 흡수를 지연시켜서 식후 고혈당의 폭을 감소시킨다.

  • PDF