• Title/Summary/Keyword: 지연검사 시간

Search Result 234, Processing Time 0.03 seconds

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients (림프종 환자에서의 갈륨, Tl-201 그리고 Tc-99m MIBI 섭취의 비교)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Kyung-Hee;Lee, Hyung-Woo;Hyun, Myung-Soo;Lee, Jae-Tae;Lee, Kyu-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.2
    • /
    • pp.107-115
    • /
    • 2002
  • Purpose: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. Materials and Methods: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. Results: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. Conclusion: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.

  • PDF

Predictive Values of Early Rest/24 Hour Delay T1-201 Perfusion SPECT for Wall Motion Improvement in Patients with Acute Myocardial Infarction After Reperfusion (급성 심근 경색 환자에서 재관류 후 조기에 시행한 휴식/24시간 지연 T1-201 심근 SPECT의 심근벽 운동 호전 예측능)

  • Hyun, In-Young;Kwan, June
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.259-265
    • /
    • 1998
  • Purpose: We studied early rest/24 hour delay T1-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Materials and Methods: Among 17 patients (male/female= 11/6, age: $59{\pm}13$) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay: 11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct-related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest T1-201 perfusion SPECT less then 6 hours after reperfusion and delay T1-201 perfusion SPECT next day. T1-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest T1-201 uptake ${\le}2$ or combination of rest T1-201 uptake ${\le}2$ or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ${\ge} 1$ grade in follow up echo compared with the baseline values. Results: Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest T1-201 uptake were 99%, and 54%. PPV and NPV of rest T1-201 uptake were 100% and 52% respectively. Predictive values of combination of rest T1-201 uptake and late reversibility were not significantly different compared with predictive values of rest T1-201 uptake only. Conclusion: We conclude that early T1-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative predictive values in patients with acute myocardial infarction after reperfusion.

  • PDF

A Study on Optimal Inspection Interval for the Major Components of Construction Lift (건설용 리프트의 운행정보 및 고장데이터 분석을 통한 주요 부품별 점검주기 산출 연구)

  • Soh, Jiyune;Bae, Jaehoon;Han, Choonghee;Lee, Junbok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.3
    • /
    • pp.68-77
    • /
    • 2015
  • One of recent concerns for super-tall buildings is how to manage hoisting plans and equipment efficiently. Disasters are frequently occurred in relation to electromotive hoists and cranes which are commonly used in construction sites. For construction lifts, particularly, it is highly important to conduct regular inspections or prepare against breakdown in terms of safety. However, unfortunately the reality is that regular inspections are only flatly conducted according to operating hours only. A lift, whose life span is subject to the complicated considerations such as operating hours, loading condition, and the like of each component, is far too invalid as a means of maintenance. As a way to resolve this problem and improve its convenience and safety for users, this study intends to calculate individual inspection interval for the main components of lifts by measuring their actual operating hours with sensing technology and analyzing their historical data. The findings of study include calculation of inspection intervals for the main components of lifts and classification of components to check by the actual operating hours of lift (40, 90, 130, 400 hours), which are drawn up into tables. This will make an opportunity to suggest efficient maintenance measures by enabling prevention of safety accidents and enhancement of safety for workers. Also, it will lead to increasing productivity of works by eliminating sources of delaying the term due to the breakdown of lifts.

Quality Changes of Nabak Kimchi During Storage with Different Levels of Fermentation (발효 조건과 저장기간에 따른 나박김치의 특성 변화)

  • Lim, Su-Youn;Lee, Hye-Ran;Lee, Jong-Mee
    • Journal of the Korean Society of Food Culture
    • /
    • v.20 no.4
    • /
    • pp.468-475
    • /
    • 2005
  • To determine the effect of different fermentation level on the quality of Nabak Kimchi during storage, this study was carried by analysing the result of physico-chemical properties, microbiological characteristics and sensory evaluation of Nabak Kimchi stored up to 24 days. For the physico-chemical properties, pH, total acidity, reducing sugar, carbon dioxide contents, color values were investigated while for the microbiological characteristics, total microbial counts and lactic acid bacteria were studied. Nabak Kimchi products were fermented at six different level of temperature and time and stored in Kimchi refrigerator at $4^{\circ}C$ for 24 days. As the storage period increased, the pH values of LF15, SF25 and LF25 decreased rapidly after initial fermentation and the pH values of SF4, LF4 and SF15 increased slightly in the beginning and then decreased. total acidity increased as storage period proceeded. the amount of reducing sugar was 4.92mg/ml before fermentation and increased significantly and reached its maximum values then decreased. lightness and redness of Nabak Kimchi decreased as storage period became longer, but yellow of Nabak Kimchi increased during storage. Total microbial counts of SF25 and LF25 reached to the highest at the 6th day and total microbial counts of LF15 reached to the highest at the 12th day and then significantly decreased. However, total microbial counts of SF4, LF4 and SF15 continuously increased up to the 24th day. The number of lactic acid bacteria was similar to the phase of the change of total microbial counts.

Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction (급성 심근경색 환자의 Tc-99m Tetrofosmin 심근 관류 지연영상에서 관찰되는 역재분포 현상의 임상적 의의)

  • Park, Soon-Ah;Kim, Dae-Weung;Kim, Chang-Guhn;Jeong, Jin-Won;Kim, Nam-Ho;Yun, Kyeong-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.112-119
    • /
    • 2009
  • Purpose: This study was performed to investigate the clinical significance of reverse redistribution(RR) phenomenon detected on delayed Tc-99m tetrofosmin myocardial single photon emission computed tomography(SPEG) in patients with acute myocardial infarction after revascularization. Materials and Methods: A Tc-99m tetrofrosmin myocardial SPECT was performed in 67 consecutive patients after revascularization for acute myocardial infarction. Myocardial SPECT imaging was performed for early imaging at 40 min and for delayed imaging at 180 min after reinjection at myocardial stress. Regional myocardial uptakes were scored by 4-point scoring in the left ventricular wall divided into 17 segments. Reverse redistribution was defined as an increase of more than 2 point in the activity score on the delayed image. Follow-up myocardial SPECT and coronary angiography(CAG) were performed 9 months later. Results: On myocardial SPECT performed following revascularization, RR was observed in 100 of all 319 segments(31%) and in 43 patients(64%). The abnormalities of perfusion and regional wall motion were more severe in the patients with RR compared to those without RR(p<0.05). On follow-up myocardial SPECT, the myocardial perfusion, regional wall motion, and myocardial thickness were significantly improved in the patients with RR(p<0.05) however, these changes were not significant in those without RR. There was no significant difference between the patients with RR and those without RR in the occurrence of restenosis on CAG. Conclusions: In patients with acute myocardial infarction, the regions showing the RR phenomenon on delayed Tc-99m tetrofosmin SPECT may reflect viable myocardium and indicate recovery of salvaged myocardium.

In vivo Biological Function of a Fibrinolytic Enzyme after Oral Adminstration (혈전용해효소의 경구투여에 의한 생체 내 작용)

  • Lee, Young-Hoon;Lee, Sung-Ho;Park, Ki-Hoon;Choi, Young-Ju;Lee, Sang-Won;Kim, Cheol-Ho;Cho, Soo-Jeong;Gal, Sang-Wan
    • KSBB Journal
    • /
    • v.21 no.6 s.101
    • /
    • pp.433-438
    • /
    • 2006
  • A fibrinolytic enzyme gene (BCF-1) was subcloned to the pEB vector which is high expression vector in the Bacillus host. The enzyme was purified by using FPLC after ammonium sulfate precipitation. The enzyme was oral-administrated to the rat and checked the bleeding time, blood clotting time and fibrinolytic effect of the serum. In the bleeding time retardation test, it was longer about 1.7 fold in the feeding rat than without feeding. The serum of rat feeded with the enzyme had the fibrinolytic activity from 1 hour to 3 hours after oral-administration. After 3 hours from feeding, the fibrinolytic activity was decreased gradually. Also blood clotting time after bleeding was longer than that of control rat. The enzyme could be detected at band of 30,000 Da in the blood by western blotting. The enzyme was not harmful to the all internal organs of the rats. Taken together, the enzyme originated from B. subtilis BB-1 can be a candidate to develop the drug for thrombosis, arteriosclerosis and myocardial infarction.

Sensory and Mechanical Characteristics of Surichwi-injeulmi by Adding Surichwi Contents (수리취 인절미의 수리취 첨가량에 따른 텍스쳐 특성)

  • 이숙미;조정순
    • Korean journal of food and cookery science
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • The purpose of this study was to investigate sensory and mechanical characteristics of Surichwi-injeulmi by adding Surichwi contents. According to sensory evaluation of Surichwi-injeulmi, the acceptance was the best in the color, flavor and overall quality when adding 20% Surichwi. As the additional ratio of Surichwi was increased, the lightness and yellowness were decreased, however, the redness was negatively increased. As a results of textural analysis of Surichwi-injeulmi by adding Surichwi contents in storing at 20$\^{C}$, the hardness, chewiness, gumminess and cohesiveness were decreased with the increased by adding Surichwi contents. The hardness, chewiness, gumminess and cohesiveness were decreased by increased storage time, whereas the elasticity was increased. Textural characteristics of Surichwi-injeulmi added 30% and 40% Surichwi in storing at 20$\^{C}$ showed less change than those of 0 and 10% group.

  • PDF

Delayed closure effect in preterm infants with patent ductus arteriosus (미숙아 동맥관개존증의 지연된 폐쇄가 예후에 미치는 영향)

  • Lee, Hyun Ju;Sim, Gyu Hong;Jung, Kyung Eun;Lee, Jin A;Choi, Chang Won;Kim, Ee Kyung;Kim, Han Suk;Kim, Beyong Il;Choi, Jung-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.10
    • /
    • pp.1065-1070
    • /
    • 2008
  • Purpose : This study aims to determine whether early closure (within 7 d) of significant patent ductus arteriosus (PDA) with indomethacin or ligation reduces neonatal morbidity when compared with delayed closure (after 7 d). Methods : Fifty-eight extremely-low-birth-weight infants admitted to the NICU of Seoul National University Hospital from April 2005 to May 2007 with PDA were studied retrospectively. Results : The mean gestational age (GA) was $26{\pm}2weeks$ (range, 23-32 wk), and the birth weight was $782{\pm}146g$ (range, 430-990 g). The delayed closure group was associated with early GA ($25.7{\pm}1.7wk$ vs $27.1{\pm}2.0wk$, P=0.013), in vitro fertilization (IVF) (55% vs 24%, P=0.017), and the absence of preeclampsia (5% vs. 34%, P=0.013). There was no difference in ductal size between the early closure and delayed closure groups. The incidence of bronchopulmonary dysplasia (95% vs 65%, P=0.012) and intraventricular hemorrhage (70% vs. 39%, P=0.027) increased in the delayed closure group. Using regression analysis adjusted for gestational age, delayed closure correlated positively with the duration of ventilator support (P=0.008), hospitalization (P=0.020), time to full enteral feeding (P<0.001), and total parenteral nutrition (P=0.010). Conclusion : Delayed closure of the hemodynamically significant patent ductus arteriosus in extremely-low-birth-weight infants is significantly related to the development of various morbidities. Thus, early closure of PDA is needed within the first week of life.

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.