• Title/Summary/Keyword: 지연검사 시간

Search Result 234, Processing Time 0.03 seconds

Optimal Scan time Analysis for Pancreatic Cancer Distinction in Dual time PET-CT Exam (이중시간 PET/CT 검사에서 췌장암 판별을 위한 최적의 Scan time 분석)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.305-311
    • /
    • 2019
  • In this study, present the most useful delay scan time by statistical analysis of SUVm data for 30 suspected pancreatic cancer patients. Two statistical analysis and a mathematical model was applied to the theoretical formula by glucose and insulin mechanics, and a mathematical model was created. Statistical analysis was performed via Metlab p/g. Optimal delay scan time was suggested by Metlab p/g for the change of SUV value over time.In this study, for diagnosis pancreatic cancer by dual time point PET/CT, propose optimal delay scan time 131.5 minuts. The proposed delay scan time showed statistical reliability applicable to the diagnosis of pancreatic cancer (p<0.05). Delayed scanning with the suggested delay scan time of 131.5 minutes is considered to be useful for the diagnosis of pancreatic cancer compared to general PET / CT scan.hen the delayed test is performed with the proposed delay scan time 131.5 minuts, Compared with general PET/CT scans.

Study of SUVm Cut-off Value for the Distinction of Pancreatic Cancer In PET/CT Exam (PET/CT 검사에서 췌장암 판별을 위한 SUVm 경계값 연구)

  • Chang, Boseok;Kim, Jae Ho;Liu, Guoxu;Jang, Eun Sung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.567-575
    • /
    • 2017
  • In this study, when diagnosis pancreatic cancer by dual time point PET/CT, we propose SUVm 2.52 as the threshold value for performing the dual time point PET/CT exam. The hypothesis of normal distribution was adopted through data conversion of 60 pancreatic diseases. The proposed SUVm2.52 boundary value showed a significance level that could be applied to both 120 and 180 minutes of delay time scan for pancreatic cancer determination (p<0.05). C-value variation shows that delay time 2 hour test is more useful than delay time 3 hour test. When the SUVm 2.52 is set to the boundary value and the double-time point PET/CT exam is performed, the probability of distinguishing cancer from inflammation in the delayed image is 95%. When the delayed test is performed with the proposed boundary value SUVm 2.52, Compared with general PET / CT scans, it is thought that it may be helpful to distinguish pancreatic cancer.

Incremental Techniques for Timing Analysis Considering Timing and Circuit Structure Changes (지연시간과 회로 구조 변화를 고려한 증가적 타이밍 분석)

  • O, Jang-Uk;Han, Chang-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.8
    • /
    • pp.2204-2212
    • /
    • 1999
  • In this paper, we present techniques which perform incremental timing analysis using Timed Boolean Algebra that solves the false path problem and extracts the timing information in combinational circuits. Our algorithm sets histories of internal inputs that are substituted for internal output and extracts maximal delays through checking sensitizability of primary outputs. Once finding the sum of primitive delay terms, then it applies modified delay with referencing histories of primary output and it can extract maximal delays of primary outputs fast and efficiently. When the structure of circuit is changed, there is no need to compute the whole circuit again. We can process partial timing analysis of computing on the gates that are need to compute again. These incremental timing analysis methods are considered both delay changes and structure of circuit, and can reduce the costs of a trial error in the circuit design.

  • PDF

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

Implementation of Composited Fuel Heater and Test Chamber for Diesel Cars (디젤 차량용 통합 연료히터와 시험챔버 구현)

  • Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2375-2380
    • /
    • 2013
  • In this paper, we have implemented the unified fuel heater and performance evaluation system for diesel cars. In order to strengthen an engine starting of diesel car, we need to assembly the fuel filter and heater. Especially, this assembly fuel heater is very important in winter, it is necessary for heating to operate the diesel engine. The heater for unifying the sensor and heater body can advance the performance of car and reduce the production cost. Finally, the performance test chamber is needed to evaluate the performance of heater.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

The Effect of Emotional Expression Change, Delay, and Background at Retrieval on Face Recognition (얼굴자극의 검사단계 표정변화와 검사 지연시간, 자극배경이 얼굴재인에 미치는 효과)

  • Youngshin Park
    • Korean Journal of Culture and Social Issue
    • /
    • v.20 no.4
    • /
    • pp.347-364
    • /
    • 2014
  • The present study was conducted to investigate how emotional expression change, test delay, and background influence on face recognition. In experiment 1, participants were presented with negative faces at study phase and administered for standard old-new recognition test including targets of negative and neutral expression for the same faces. In experiment 2, participants were studied negative faces and tested by old-new face recognition test with targets of negative and positive faces. In experiment 3, participants were presented with neutral faces at study phase and had to identify the same faces with no regard for negative and neutral expression at face recognition test. In all three experiments, participants were assigned into either immediate test or delay test, and target faces were presented in both white and black background. Results of experiments 1 and 2 indicated higher rates for negative faces than neutral or positive faces. Facial expression consistency enhanced face recognition memory. In experiment 3, the superiority of facial expression consistency were demonstrated by higher rates for neutral faces at recognition test. If facial expressions were consistent across encoding and retrieval, memory performance on face recognition were enhanced in all three experiments. And the effect of facial expression change have different effects on background conditions. The findings suggest that facial expression change make face identification hard, and time and background also affect on face recognition.

  • PDF

An Extended Real-Time Synchronization Protocols for Shared Memory Multiprocessors (공유메모리 다중 프로세서 실시간 시스템에서의 동기화 프로토콜)

  • Kang, Seung-Yup;Ha, Rhan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.136-138
    • /
    • 1998
  • 작업들이 자원을 공유하는 경우 예측하기 어려운 지연시간이 발생한다. 다중 프로세서 시스템에서의 자원공유로 인한 지연시간은 더욱 예측하기 어렵다. 실기간 시스템의 스케줄 가능성 검사를 위해서는 이러한 지연시간을 정확히 예측해야한다. 선점가능한 우선순위 구동 CPU 스케줄링 알고리즘에 의해서 다른 우선순위의 작업과의 동기화는 우선순위 역전 문제를 야기한다. 본 논문에서는 다중 프로세서에서의 동기화 프로토콜을 제안하고 작업의 지연시간을 분석한다. 다른 프로세서에 할당된 작업들이 수행중인 자원을 요구할 때, 자원을 수행하는 작업의 우선순위를 높여줌으로써 자원수행을 빠르게 종료하게 한다. 이로 인해 자원에 의한 지연을 최소화한다. 특히, 높은 우선순위 작업의 경우 더욱 작은 지연시간을 갖게한다. 시뮬레이션을 통한 Shared Memory Protocol [5]과의 비교, 분석 결과 성능의 향상을 보임을 알 수 있다. 다양한 작업집합에 대한 지연시간을 분석하였다.

  • PDF

Scheduling Mechanism to Group-based Result Checking in Global Computing Systems (글로벌 컴퓨팅 시스템에서 그룹 기반 정확성 검사를 위한 스케줄링 기법)

  • 김홍수;백맹순;유헌창;황일선;황종선
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.475-477
    • /
    • 2004
  • 글로벌 컴퓨팅 시스템 환경에서 자원 제공자에 의해 수행하는 연산 결과에 대한 정확성을 제공하기 위한 결과 검사 기법은 중요한 고려사항이다. 자원 제공자들은 인터넷에 연결되어 인증 없이 자율적으로 연산에 참여할 수 있기 때문에 이들에 의해 수행된 연산 결과에 대한 정확성을 보장해야만 한다. 기존 연구에서 결과에 대한 정확성을 보장하기 위해 다수 투표법과 결점 검사법을 사용하지만 정확성 검사 기법을 위한 스케줄링 기법을 사용하고 있지 않아 높은 연산 지연 시간과 부하가 발생한다. 따라서, 본 논문에서는 결과 검사에 대한 연산 지연 시간과 부하를 줄일 수 있는 신용도 기반 그룹 구성을 통한 스케줄링 기법을 제안한다.

  • PDF

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF