A Study on the Absorption of Thermal Stress on the Underground piping for the District heating (지역난방용 매설배관의 열응력 흡수에 관한 연구)

  • Kong Jae Hyang;Sin Byung Kug
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 2005
  • There have been many studies on generation equipment and plant piping, but there is no significant study result on the heat transportation pipe. As such, this study established basic theory on the compensated method among buried pipe for regional heating, and further obtained the following results by applying the conditions of AGFW and NCHPP respectively in calculation of friction and maximum installation distance for the buried pipe. Friction coefficient according to the types and physical properties of soil, friction and maximum installation distance were compared to set the application value of friction coefficient according to the location of works. Calculation formula of clay load to be applied for calculation of friction was introduced to the formula of AGFW and the formula of NCHPP that has been used in Nowon district since 1997 to determine the difference and applicability. $120^{\circ}C$ and $95^{\circ}C$ were applied in temperature difference for expansion volume to compare the arm length at the curve pipe so thai it can be reflected in the design in the future. Maximum installation distance according to thickness of pipe was compared to present the necessity of unified specification so that same kinds of pipe materials can be used for same kinds of works.

지역난방플랜트의 경제적 설계

  • 대한설비공학회
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.3
    • /
    • pp.184-190
    • /
    • 1979
  • 제 1 부에서는 지역난방배관강의 특리성을 설명한다. 난방부하에 있어서 피이크치는 별로 자주 사용되는 것이 아니며 이에 소요되는 에너지는 소량이므로 최소의 자본투자를 하도록 하여야 한다. 지역난방배관강의 건설기간동안 설비용량중의 많은 부분이 사용되지 않은 상태로 나타나 건설기간중의 이자를 고려할 때 투자비를 증가시키게 된다. 건설기간동안에는 특히 투자가 가급적 적게되도록 하여야 한다. 제 2 부에서는 동력발생과 열발생에 있어 가장 경제적이 되도록 간단하고 실용적인 방법을 설명한다. 에너지함량을 사용하여 가장 판단한 방법으로 각 부문에 대할 에너지의 환산을 할 수 있다. 이로서 열병합발전방식으로부터 열을 발생시키는 경우와 열만을 생산할 때의 연간 생산비를 계산할 수 있다. 전기에너지에 대한 수입을 고려하고 최소현가를 결정할 수 있다. 제 3 부에서는 난방망의 증가를 포함하여 지역난방플랜트의 단계적 확장에 대하여 설명한다.

  • PDF

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.

Virtual Analysis of District Heating System Using ENetPLAN (EnetPLAN을 이용한 지역난방시스템 가상 운전 분석)

  • Ahn, Jeongjin;Lee, Minkyung;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.18-25
    • /
    • 2019
  • In this study, in order to solve the problem of the program of calculating code input by experienced users in the power generation, the wide area energy network research group developed the local heating operation analysis program EntPLAN, which can be easily used by anyone, including scalability, with domestic technology. Therefore, the Commission intended to compare the heat sources, heat demand, and the results of operation of the combined heat plant (CHP) on the energy network through simulation with the EnetPLAN and the program A on the market. The results showed that the heat and power output on the energy network of the EnetPLAN and A programs were mostly similar in pattern in the simulation results of the heat supply and the operation method of the accumulator. This enabled the application of the simulation for the various operation modes of the cogeneration facilities existing on the energy network. It is expected that EntPLAN, which was developed with domestic technology, will be easily applied in the field in the future and will present efficient operation simulation results.

신형원자로로서의 일체형 가압경수로 설계특성 분석

  • 김용완;이두정;장문희
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.269-279
    • /
    • 1995
  • 가압경수로에서 증기발생기와 같은 주기기를 원자로 내부에 위치하도록 설계한 원자로를 일체형 원자로라고 분류하며, 기존 상용원자로와 같이 모든 주기기가 별도의 압력용기로 설계되어 배관계통에 의해 원자로 외부에 순환회로를 갖는 형태의 원자로를 분리형원자로라고 한다. 최근에 개발되고 있는 한 부류의 신형원자로에서는 원자로 및 계통의 단순성 추구와 계통의 높은 신뢰성으로 안전성 향상을 위해 동력원 사용 등의 능동적 안전개념 보다는 자연현상을 이용하는 피동안전개념이 널리 도입되고 있다. 본보고서에서는 이러한 신형원자로의 노형으로서 일체형원자로의 특성을 전통적인 분리형원자로와 비교, 분석, 평가하였다. 일체형원자로의 가장 큰 장점은 모든 주기기가 단일 압력용기 내에 위치하므로 일차계통이 매우 단순하고 대구경 배관이 없기때문에 대형 냉각재 상실사고가 근본적으로 방지되어 안전계통이 매우 단순하다는 것이다. 이 외에도 일체형원자로는 대단히 많은 일차냉각재 용량, 매우 큰 가압기 용량및 긴 운전원 조치시간등의 설계특성을 보유하고 있어 안전성이 탁월하다는 장점을 지니고 있다. 그러나, 일체형원자로는 모든 주기기가 단일 압력용기 내에 설치되므로 대형 원자로 용기가 요구되며, 원자로 압력용기의 제작성 및 운송 능력이 원자로의 용량을 제한하는 주된 요인이 된다. 일체형원자로의 활용으로 열병합 발전, 지역난방 및 선박용 원자로등의 중소형 원자로에 매우 적합하다고 판단되며, 뛰어난 안전성으로 인하여 사회적 수용성 이 강조되는 상용발전로로서도 적합한 노형이 될 수 있을 것으로 분석되었다.