• Title/Summary/Keyword: 지속적 양압술

Search Result 12, Processing Time 0.018 seconds

The Compliance and Effect of CPAP in Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡 환자에서 지속적 상기도 양압술의 순응도와 효과)

  • Han, Eun-Kyoung;Yoon, In-Young;Chung, Seock-Hoon
    • Sleep Medicine and Psychophysiology
    • /
    • v.13 no.2
    • /
    • pp.52-58
    • /
    • 2006
  • Objectives: Continuous positive airway pressure (CPAP) is effective in the treatment of obstructive sleep apnea syndrome (OSAS), but the major limitation of CPAP may be poor compliance. The aims of the study were to investigate the compliance and side effects of CPAP, and to evaluate the efficacy of CPAP in patients with OSAS. Methods: This study enrolled 106 patients with OSAS who took the CPAP treatment. The severity of daytime sleepiness was measured using Epworth Sleepiness Scale (ESS), and sleep quality and depressive symptoms were assessed by Pittsburgh Sleep Quality Index (PSQI) and Beck Depression Inventory (BDI), respectively. Results: During 29 months of the study period, 41.5% of patients were using CPAP and 38.7% of patients stopped using it. Compared to non-compliant patients, compliant patients had a higher PSQI score and obstructive apnea index. Among non-compliant patients, 51.2% of them stopped using CPAP within 1months. 85.7% of non-compliant patients were discomforted by the CPAP, but much more nasopharyngeal symptoms were reported in the compliant group. ESS (p<0.01), PSQI (p<0.01) and BMI (p<0.01) were reduced significantly after CPAP treatment but not BDI (p=0.86). Conclusions: We concluded that CPAP can reduce the daytime sleepiness, nocturnal sleep disturbance, and body mass index. To increase the compliance of CPAP, we suggest that some education and support are needed at the early stage of the CPAP treatment.

  • PDF

Effects of Nasal Continuous Positive Airway Pressure Application on Sympathetic Activation : Power Spectrum Analysis of Electrocardiogram in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 시행이 교감신경계 활성도에 끼치는 영향 : 심전도 스펙트럼 분석)

  • Youn, Tak;Park, Hae-Jeong;Kim, Eui-Joong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • Objectives: Obstructive sleep apnea syndrome(OSAS) is known to be associated with the changes of autonomic nervous system (ANS). Nasal continuous positive airway pressure(nCPAP) treatment was found to correct abnormal ANS changes in OSAS but it remains to be further clarified. We aimed to assess the effects of nCPAP on ANS manifested on electrocardiogram, using spectrum analysis in the subjects with OSAS. Methods: Digital polysomnography was performed in 18 patients with OSAS(mean age $43.7{\pm}16.6$ years ; 17 males, 1 female ; mean respiratory disturbance index (RDI) $48.6{\pm}20.9$) for one baseline and another CPAP nights. From each night, 300 continuous beats of ECGs without artifact were chosen from both stage 2 sleep and REM sleep and they were used for power spectrum analysis. We compared between baseline and CPAP nights the heart rate variability including VLF(very low frequency power), LF (low frequency power), HF(high frequency power), R-R means, R-R variance, and LF/HF ratio, using Wilcoxon signed ranks test. Results: In all patients, nCPAP proved to be effective in relieving apneas and snoring. During nCPAP night compared with baseline night, decreases in VLF(p<0.05), LF(p<0.01), and R-R variance(p<0.05) were found in stage 2 sleep, and decreased LF(p<0.05) was found in REM sleep. No significant differences in each sleep stage were found in other variables between the two nights. Conclusion: Our findings suggest that OSAS increases the activity of sympathetic nervous system and nCPAP application effectively decreases the activity. And nCPAP does not appear to influence the parasympathetic nervous activity in OSAS.

  • PDF

Sleep Fragementation Decreases during the nCPAP Titration Night in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 압력 처방 검사 시 나타나는 수면분절의 감소)

  • Lee, Jin-Seong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Objectives: Obstructive sleep apnea syndrome (OSAS) not only causes respiratory disturbances during sleep but also decreases the quality of nocturnal sleep through sleep fragmentation and sleep structure change. We aimed at comparing the changes in sleep fragmentation and structure between baseline (diagnostic) nocturnal polysomnography (NPSG) and nCPAP (nasal continuous positive airway pressure) titration trial. Methods: One hundred and three patients with a baseline night of respiratory disturbance index (RDI) of 5 or greater and reduced RDI score during nCPAP titration night were retrospectively selected for the study. Sleep fragementation and sleep structure between baseline NPSG and the NPSG during nCPAP titration were compared. Sleep fragmentation index (SFI) was defined as the total number of awakenings and shifts to stage 1 sleep divided by the total sleep time in hour. SFI and other polysomnographic parameters were statistically compared between the two nights. Results: SFI during baseline NPSG and nCPAP titration nights were $29.0{\pm}13.8$ and $15.2{\pm}8.8$, respectively, indicating a significant SFI decrease during nCPAP titration (t=9.7, p<0.01). SFI showed significant negative correlations with sleep efficiency (r=-0.60, p<0.01) and total sleep time (r=-0.45, p<0.01) and a positive correlation with RDI (r=0.28, p<0.01). Conclusion: Use of nCPAP, even during the titration, significantly decreases sleep fragmentation and improves sleep structure in OSAS patients. We suggest that SFI may be utilized as a measure of assessing OSAS severity and nCPAP efficacy.

  • PDF

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

Nasal Continuous Airway Pressure Titration Unmasks Periodic Limb Movements in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술에 따른 주기성 사지운동증의 표출)

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.1
    • /
    • pp.103-110
    • /
    • 1998
  • Objectives : High co-morbidity of periodic limb movements during sleep(PLMS) and obstructive sleep apnea syndrome(OSAS) is well known and their incidences tend to increase in the elderly. Previous studies have inconsistently rep0l1ed increase or no change of periodic limb movement index(PLMI) by nasal continuous positive airway pressure(CPAP) in OSAS without analyzing possible variables affecting PLMI. We attempted to examine PLMI change evoked during CPAP titration and also factors affecting it in OSAS. Methods : Twenty-nine OSAS patients(M:F=26:3, mean age: $51.6{\pm}10.6\;yrs$) without other sleep disorders except for PLMS were selected, based on the nocturnal (baseline) polysomnograhy. Another night of noctumal polysomnography was performed for CPAP pressure titration. We compared between those two nights PLMI, mean and lowest $SaO_2$, and sleep variables. We also calculated PLMI differences between baseline and CPAP nights, named as delta PLMI (value of CPAP night PLMI minus value of baseline night PLMI). Correlations were calculated between delta PLMI and factors such as age, body mass index, applied CPAP pressure, baseline night values of respiratory disturbance index, mean and lowest $SaO_2$, and sleep parameter differences between baseline and CPAP nights. Results : Decrease of RDI(p<.01) and increase in mean and lowest $SaO_2$ (p<.05, p<.01) were observed during CPAP night. No sleep parameters showed significant change except for the decrease of total stage 1 sleep%(p<.01) during CPAP night. Ten out of 29 patients showed PLMI increase, while the other 19 patients showed either no change(n=14) or even PLMI decrease(n=5) during CPAP night. The 10 patients showing PLMI increase during CPAP night showed a significant positive correlation between delta PLMI and baseline night RDI(p<.05), which meant that PLMI increase was found to be more prominent in higher RDI patients than in lower RDI ones. There were no significant correlations between delta PLMI and other factors in the other 19 patients. Conclusions : We suggest that during the baseline night PLMS would have been underscored and/or masked due to the overlapping of PLMS and apneas/hypopneas or the arousals induced by apneas/hypopneas. Despite its still unknown mechanism, the CPAP application may unmask PLMS and increase PLMI in a subgroup of OSAS patients. It needs to be evaluated further whether the chronic CPAP use sustains the above finding.

  • PDF

Therapeutic Change of Sleep Structure and Function by Continuous Positive Airway Pressure Application in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면(睡眠) 무호흡증(無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)에 따른 수면구조(睡眠構造) 및 기능(機能) 변화(變化))

  • Jeong, Do-Un;Yoon, In-Young;Shim, Young-Soo
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.2
    • /
    • pp.172-181
    • /
    • 1994
  • Obstructive sleep apnea syndrome(OSAS) is most frequently diagnosed in the sleep laboratories and its severity is objectively estimated. In terms of treatment, the most prevalent method is the continuous positive airway pressure(CPAP) application as of now. However, in Korea, CPAP is still not sufficiently known and it is attributable to the fact that sleep study facilities have not been popularized. In this article, the authors present their own experience with CPAP in nine subjects with OSAS. In this study, CPAP was found to decrease stage 1 sleep and to increase stage 2 sleep, with increasing mean oxygen saturation and decreasing lowest oxygen saturation during nocturnal sleep. Also, it tended to increase sleep continuity and generally to improve sleep architecture. Rebound slow wave and/or REM sleep stages during CPAP were also noted in 8 out of 9 cases. The authors suggest that CPAP should be considered as the primary mode of treatment for patients with obstructive sleep apnea syndrome and related educational programs for physicians should be developed and provided by sleep specialists.

  • PDF

Compliance of Nasal Continuous Positive Airway Pressure in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 환자의 지속적 상기도 양압술 순응도)

  • Choi, Jong-Bae;Lee, Seung-Hee;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.13 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • Objectives: Nasal continuous positive airway pressure (nCPAP) is the treatment of choice and has been shown to reduce the frequency of nocturnal respiratory events, improve sleep architecture, and decrease daytime sleepiness in patients with obstructive sleep apnea syndrome (OSAS). However, little is known about the compliance of nCPAP treatment in Korea. Our objective was to look into the nCPAP compliance and examine the factors influencing it. Methods: We reviewed the records of one hundred and twenty consecutive patients with OSAS referred for nocturnal polysomnography with nCPAP pressure titration during the period of January 1995 through April 1999 to the Seoul National University Hospital. We performed a telephone interview and obtained data from eighty-three patients. Results: In sixty patients who had accepted nCPAP treatment, twenty-six patients (43.3%) were still using nCPAP device, while thirty-four patients (56.7%) stopped using it. Fifteen patients (25%) were using nCPAP device everyday. In thirty-four patients who discontinued nCPAP use, twenty-five patients (73.5%) did within the first three months, and thirty-one (91.2%) within the first year. Significant predictor of long-term nCPAP use was the presence of subjective daytime sleepiness before nCPAP application. Conclusions: Long-term compliance with nCPAP treatment appears to be associated with the presence of subjective daytime sleepiness before nCPAP application. Long-term compliance with nCPAP may be mostly predicted from the usage pattern within the first three months of use.

  • PDF

Preliminary Study of The Periodic Limb Movement Disorder Following Nasal CPAP : Is It Associated With Supine-Sleeping Position? (지속적 양압술과 수면중 주기적 사지운동 장애의 관계에 대한 예비적 연구 : 앙와위가 주기적 사지운동 장애와 관련되는가?)

  • Yang, Chang-Kook;Clerk, Alex A
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.164-171
    • /
    • 1997
  • Introduction : Periodic limb movement disorder (PLMD) is shown to common in patients with OSA and may become evident or worsened when treated with nasal continuous positive airway pressure (CPAP). Whether this is due to im proved sleep continuity. adverse nocturnal body positioning, uncovered by CPAP, or due to the CPAP stimulus is still debat-ed. We hypothesized that the increase in PLM activity following CPAP is associated with more supine-sleeping tendencies when being treated with CPAP. In the present work, we compared differences in the PLMD index (PLMI) and sleeping position of patients with sleep disordered breathing before and after CPAP treatment. Method : We studied 16 patients (mean age 46 yr, 9M, 7F) with OSA (11 patients) or UARS (5 patients) who either had PLMD on initial polysomnogram (baseline PSG) or on nasal CPAP trial (CPAP PSG). All periodic leg movements were scored on anterior tibialis EMG during sleep according to standard criteria (net duration; 0.5-5.0 seconds, intervals; 4-90 seconds. 4 consecutive movements). Paired t-tests compared PLMD index (PLMI), PLMD-related arousal index (PLMD-ArI), respiratory disturbance index (RDI), and supine sleeping position spent with baseline PSG and CPAP PSG. Results : Ten patients (63%) on baseline PSG and fifteen patients (94%) on CPAP PSG had documented PLMD ($PLMI{\ge}5$) respectively with significant increase on CPAP PSG(p<0.05). Ten patients showed the emergence (6/10 patients) or substantial worsening (4/10 patients) of PLMD during CPAP trial. Mean CPAP pressure was $7.6{\pm}1.8\;cmH_2O$. PLMI tended to increase from baseline PSG to CPAP PSG, and significantly increase when excluding 2 outlier (baseline PSG, $19.0{\pm}25.8/hr$ vs CPAP PSG, $29.9{\pm}12.5/hr$, p<0.1). PLMD-ArI showed no significant change, but a significant decrease was detected when excluding 2 outlier (p<0.1). There was no significant sleeping positional difference (supine vs non-supine) on baseline PSG, but significantly more supine position (supine vs non-supine, p<0.05) on CPAP PSG. There was no significant difference in PLMI during supine-sleeping and nonsupine-sleeping position on both of baseline PSG and CPAP PSG. There was also no significant difference in PLMI during supine-sleeping position between baseline PSG and CPAP PSG. With nasal CPAP, there was a highly significant reduction in the RDI (baseline PSG, $14.1{\pm}21.3/hr$ vs CPAP PSG, $2.7{\pm}3.9/hr$, p<0.05). Conclusion : This preliminary data confirms previous findings that CPAP is a very effective treatment for OSA, and that PLMD is developed or worsened with treatment by CPAP. This data also indicates that supine-sleeping position is more common when being treated with CPAP. However, there was no clear evidence that supine position is the causal factor of increased PLMD with CPAP. It is, however, suggested that the relative movement limitation induced by CPAP treatment could be a contributory factor of PLMD.

  • PDF

A Case of Childhood Obstructive Sleep Apnea Syndrome with Co-morbid Attention Deficit Hyperactivity Disorder Treated with Continuous Positive Airway Pressure Treatment (지속적(持續的) 상기도(上氣道) 양압술(陽壓術)을 시행(施行)하여 치료효과(治療效果)를 본 주의력(注意力) 결핍(缺乏).과잉(過剩) 운동장애(運動障碍)를 동반(同伴)한 소아기(小兒基) 폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症) 1례(例))

  • Sohn, Chang-Ho;Shin, Min-Sup;Hong, Kang-E;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • Obstructive sleep apnea syndrome(OSAS) in childhood is unique and different n-om that in adulthood in several aspects, including pathophysiology, clinical features, diagnostic criteria, complications, management, and prognosis. Characteristic features of childhood OSAS in comparison with the adult form are the variety of severe complications such as developmental delay, more prominent behavioral and cognitive impairments, vivid cardiovascular symptoms, and increased death risk, warranting a special attention to the possible diagnosis of OSAS in children who snore. However, the childhood OSAS is often neglected and unrecognized. We, therefore, report a case of very severe OSAS in a 5-year-old boy who was sucessfully treated with continuous positive airway pressure(CPAP) treatment. Interestingly, the patient was comor-bid with the attention deficit hyperactivity disorder. Prior to the initial visit to us, adenotonsillectomy had been done at the age of 4 with no significant improvement of apneic symptoms and heavy snoring. On the initial diagnostic procedures, marked degree of snoring was audible even in the daytime wake state and the patient was observed to be very hyperactive. Increased pulmonary vascularity with borderline cardiomegaly was noted on chest X-ray. The baseline polysomnography revealed that the patient was very sleep-apneic and snored very heavily, with the respiratory disturbance index(RDI) of 46.9 per hour of sleep, the mean SaO2 of 78.8%, and the lowest SaO2 of 40.0%(the lowest detectable oxygen level by the applied oxymeter). The second night polysomnography was done for CPAP titration and the optimal pressure turned out to be $8.0\;cmH_2O$. The applied CPAP treatment was well tolerated by the patient and was found to be very effective in alleviating heavy snoring and severe repetitive sleep apneas. After 18 months of the CPAP treatment, the patient was followed up with nocturnal polysomnography(baseline and CPAP nights) and clinical examination. Sleep apneas were still present without CPAP on the baseline night. However, the severity of OSAS was significantly decreased(RDI of 15.7, mean SaO2 of 96.2%, and the lowest SaO2 of 83.0%), compared to the initial polysomnographic findings before initiation of long-term CPAP treatment. Wechsler intelligence tests done before and after the CPAP treatment were compared with each other and surprising improvement of intelligence(total 9 points, performance 16 points) was noted. Clinically he was found to be markedly improved in his attention deficit hyperactive behavior after CPAP treatment, but with minimal change of TOVA(test of variables of attention) scores except conversion of reaction time score into normal range. On the chest X-ray taken after 18 months of CPAP application, the initial cardiopulmonary abnormalities were not found at all. We found that the CPAP treatment in a young child is very effective, safe, and well-tolerated and also improves the co-morbid attention deficit hyperactive symptoms. Overall, the growth and development of the child has been facilitated with the long-term use of CPAP. Cardiovascular complications induced by OSAS have been also normalized with CPAP treatment. We suggest that early diagnosis and active treatment intervention of OSAS in children are crucial in preventing and ameliorating possible serious complications caused by repetitive sleep apneas and consequent hypoxic damage during sleep.

  • PDF

A Case of Continuous Positive Airway Pressure Therapy in a Patient with Central Sleep Apnea and Heart Failure (중추성 수면 무호흡이 동반된 심부전 환자에서 지속적 상기도 양압술 적용 1례)

  • An, Jee Young;Kim, Shin Bum;Kang, Hyeon Hui
    • Sleep Medicine and Psychophysiology
    • /
    • v.24 no.2
    • /
    • pp.118-123
    • /
    • 2017
  • Central sleep apnea (CSA) is a highly prevalent comorbidity in patients with heart failure and may present in 25 to 40 percent of heart failure patients. Continuous positive airway pressure (CPAP) is the primary therapeutic option and effective in treatment of obstructive sleep apnea (OSA). In heart failure patients with CSA, several trials of CPAP showed a number of positive effects in heart failure treatment. A 58-year-old male visited the hospital because of dyspnea and he was diagnosed as heart failure with ischemic heart disease. He underwent coronary angiography and received percutaneous coronary intervention due to stenosis at the middle of left anterior descending coronary artery. However, dyspnea was not completely improved after treatment with percutaneous coronary intervention. The patient also experienced snoring and sleep apnea which worsened with symptom of dyspnea in the recent year. We suspected CSA and the patient underwent polysomnography to confirm whether sleep apnea was present. During the polysomnography, CSA with Cheyne-Stokes respiration (CSR) was observed and apnea-hypopnea index was 45.9/hr. The patient was treated with CPAP. After CPAP treatment, hypoxemia and CSA were resolved and dyspnea was improved with reducing NYHA class. We report a case successfully treated with clinical improvement by presuming CSA in a patient with heart failure.