• Title/Summary/Keyword: 지붕 기울기

Search Result 7, Processing Time 0.027 seconds

A Study on the Optimum Slope of the Roof for Minimum Cooling Load (냉방부하 최소화를 위한 지붕의 최적기울기에 관한 연구)

  • Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.119-123
    • /
    • 2005
  • The main purpose of this study is to define an optimum slope of the roof that demands minimum cooling load of the building, when the roof is affected by the solar and wind energy. Two different roof shapes were chosen: hip, gabled. The cooling load of building having those roof shapes was calculated through the computer simulation, using DOE program. For the simulation, the angle of the roof and angle of the orientation was changed. In the conclusion of this paper, an optimum slope of the roof which causes minimize cooling load is presented according to the roof shape and orientation. The result of this study could provide a practical design guideline for determining the roof angle for various climatic conditions.

A Study on the roof curved ratio and slope of Korean Traditional Wooden Building - Focused on the Central Hall of Buddhist Temple - (전통목조건축물 지붕곡과 기울기에 관한 연구 - 사찰의 주불전을 중심으로 -)

  • Go, Jung-Ju;Lee, Jeong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3894-3906
    • /
    • 2014
  • The aim of this study was to classify the central Buddhist temple among the state-designated cultural assets, which were measured precisely, into the gable roof buildings and the gambrel roof buildings to analyze the Ang-Goak, Inside waist, ridge ratio, and roof inclination represented on the roof, and prepare basic objective material for the restoration and repair of cultural assets. As a result, as for the relationship between the roof curve and the inclination of the gable roof building and gambrel roof building, the following conclusions could be drawn. First, the Ang-Goak and Inside waist of the gable roof building had a close correlation with the building size, and the internal high pillar existence. In addition, the Ang-Goak and Inside waist were shown in the 7-ryangga structure, which is greater in size than in the 5-ryangga structure. This was found to be related to the building size. Second, the Ang-Goak and Inside waist of the gable roof building has a correlation with each other, and it was found that Inside waist also was large in the building with a larger Ang-Goak. The roof inclination rarely had a connection with variable factors (plane factor, elevation factor, and cross section factor). The sizes of Ang-Goak, Inside waist, and ridge ratio were similar in the outside 1 chulmok and outside 2 chulmok of gongpo but those sizes were relatively larger in outside 3 chulmok. Third, the Ang-Goak and Inside waist of the gambrel roof building moved independently for each building without a correlation with each other, unlike the case of the gable roof building. The front and the side showed a correlation with each other, and in the building with the large curve of the front side, the curve was also large in the sides. Fourth, in the case of the building with a high pillar inside the gambrel roof building, the Ang-Goak and Inside waist were larger. On the other hand, they were smaller in the case of a building without a high pillar. This was found to have a close relationship with the building size. In addition, the ridge ratio has a close connection with the building size and building height. Therefore, the ridge ratio is larger in a high building or large sized building. The roof inclination rarely has a correlation with variable factors, as in the case of the gable roof building.

An Experimental Study on the Required Performances of Roof Concrete Placed in the In-ground LNG Storage Tank (지하식 LNG 저장탱크의 지붕 콘크리트의 요구성능에 관한 실험적 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.339-345
    • /
    • 2013
  • This study is to derive from the required performances and the optimum mix proportion of the roof concrete placed in the in-ground LNG storage tank with a capacity of 200000 $m^3$, and propose the actual data for site concrete work. The concrete placing work without sliding and segregation in the fresh concrete condition is very important because the slope of domed roof is varied in the large range by its curvature. Also the control of hydration heat and the strength development at test ages are classified with massive section about 1.4 m thick and considered to the pre-stressing work and removal of air support after concrete placing work. Considering above condition, slump range is selected $100{\pm}25$ mm under the slope $20^{\circ}$ and $150{\pm}25$ mm over the slope $20^{\circ}$ s until 60 minutes of elapsed time. Also, the roof concrete is satisfied with compressive strength range including design strength at 91 days (30 MPa), pre-stressing work at 7 days (10 MPa), air support removal work at 21 days (14 MPa). Replacement ratio of limestone powder is determined by confined water ratio test and main design factors include water-cement ratio (W/C), sand-aggregate ratio and dosage of admixture. As test results, the optimum mix proportion of the roof concrete used low heat cement is as followings. 1) Replacement ratio of limestone powder 25% by confined water ratio test 2) Water-cement ratio 57.8% 3) Sand-aggregate ratio 42.0%. Also, test results for the adiabatic temperature rising test is satisfied with its criteria and shown the lower value compared to preceding storage tank (TK-13, 14). These required performances and the optimum mix proportion is to apply the actual construction work.

Analysis of Structural Characteristic of Small Scale Vinyl House by Region (지역별 소형비닐하우스의 구조특성 분석)

  • 이종원;이석건;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.11a
    • /
    • pp.306-315
    • /
    • 2002
  • 본 연구는 지역별로 단동비닐하우스의 설치현황, 단면형상, 폭, 지붕높이, 측고, 측벽기울기, 골조재의 규격, 서까래간격, 가로대의 설치위치 및 개수, 내용년수 등을 현장조사를 통하여 비닐하우스의 구조실태를 파악하였다. 설치지역별에 따른 단동비닐하우스의 구조특성을 조사ㆍ분석한 본 연구결과는 관행적으로 시공되고 있는 소형비닐하우스의 구조표준화를 위한 기초자료로 활용할 수 있으며 매년 반복되고 있는 강풍과 폭설로 인한 소형비닐하우스의 피해를 줄일 수 있는 안전모델 개발의 기초자료로 활용할 수 있을 것으로 판단된다.

  • PDF

Effect of the Eave Width and the Vertical Rain Proof Facilities on Ventilation and Air Velocity Distribution in Hanwoo Loose Barn (개방한우사의 처마와 수직 비가림시설이 환기와 풍속 분포에 미치는 영향)

  • Lee, Seung-Joo;Jo, Hyeon-Jun;Kim, Dong-Hoon;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.45 no.4
    • /
    • pp.87-93
    • /
    • 2011
  • This study was carried out to determine more effective way in eave structure between lengthening roof just as standard plan and replacing 3 types of vertical rain roof facility by using computational fluid dynamics (CFD) simulation to reduce the heat stress of Hanwoo, increase the effect of dryness of room floor, rain proof and ventilation efficiency. The simulation which did with mean wind velocity (1.2 m/s) result showed that the case of lengthening of roof just as standard design was more effective than the cases of vertical establishment of rain proof facility.

Building occlusion correction for high resolution satellite imagery (고해상도 위성영상의 건물 폐색영역 보정)

  • Kim, Hye-Jin;Choi, Jae-Wan;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.59-62
    • /
    • 2008
  • 고해상도 위성영상의 관측시, 위성센서는 보통 지표면으로부터 어느정도의 기울기를 갖는 상태에서 촬영이 되기 때문에 영상 내에서 건물은 지표면에 누워있는 형태로 나타나게 된다. 때문에 건물의 옆벽면 및 지붕에 의해 지표의 일부가 가려지게 되는데 이를 건물에 의한 폐색영역이라 한다. 이러한 폐색영역은 건물의 기복오차가 제거된 정사영상에서는 검게 비어있는 상태로 남게 되며 시각적으로나 영상판독시 불편을 초래하여 위성영상을 베이스 맵으로 사용하기 어렵게 하는 요인이 된다. 이러한 폐색영역을 보정하기 위해서는 일반적으로 동일 영역에 대한 두 장 이상의 영상을 이용하여 폐색 지역을 채워넣는 작업을 수행하나, 이 방법은 위성영상 구입 및 처리 비용에 대한 부담이 커 실제로 자주 사용되지 못 한다. 본 연구에서는 고해상도 위성 단영상의 건물에 의한 폐색영역에, 주변 화소값들의 분광 및 기하학적 특성을 이용하여 복원하는 기술인 inpainting 기법을 적용하여 그 보정 결과를 평가하고 활용 가능성을 검증해보고자 한다.

  • PDF

A study on the variant placement method of the traditional wooden architecture, rafter (전통 목조건축 서까래의 이형적(異形的) 배치 방식 연구)

  • Hong, Eun-ki;Chang, Hun-duck
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.4
    • /
    • pp.110-125
    • /
    • 2015
  • This study is objected to investigate the repairing method and the modification period of rafters via the transformation traces left in the superciliums, where repair process takes places frequently. This is the basic research of analyzing the architectural features of Deokkeori, one of the additional-rafter methods. Deokkeori method can be described as using Deokdori in the top section of Hayeon, and placement of Sangyeon above it. This method was started to be used since middle of the Joseon dynasty period(middle 18th Century) and mainly used at 19th Century to resist the transformation caused by repairing. It had been gradually developed from non-application stage to application stage including additional usage of complement. The architectural features of Deokkeori can be categorized into four. First, the usage of Deokdori to connect Sangyeon to the top section of Hayeon. It reduct the direct connection between Sangyoen and Hayeon, therefore give constructive benefits and prevent the downfall of the eaves by increasing the power which pressing the top section of Hayeon. Second, it gives the autonomy to the inside structure of ceiling by comprising it. By using Deokdori, the limit of top section's longitude was eliminated while also simplify the upper section by blocking the inside structures with ceiling. In addition, the complements occasionally seen in several buildings increase the power which pressing Hayeon. Third, the ceiling's slope has been changed to be concerned with Sangyeon, instead of Hayeon which was highly related with it before. The last factor is the thickness of rafters which used in Deokkeori. The diameter is thiner in Sangyeon than Hayeon.