• Title/Summary/Keyword: 지반종류

Search Result 620, Processing Time 0.026 seconds

Characteristics of Behavior of Brain Board - driven Clay Layers by Vacuum Loading (진공하중에 의한 Drain Board 타입 점토지반의 거동 특성)

  • Lee, Song;Yang, Tae-Seon;Park, Jong-Chan;Paik, Young-Shik
    • Geotechnical Engineering
    • /
    • v.9 no.1
    • /
    • pp.45-58
    • /
    • 1993
  • Paper drain method is one of the methods used for the improvement of soft clay as hydraulic fill sites or the seaside industrial complex. This method adopts a card board as the drain materials instead of sand piles in sand drain method. In this paper 3 types of drain board are used to fond out the characteristics of consolidation by vacuum consolidation model test. So does the no drain board test. This test causes the reduction of pore water pressure to promote the settlement without change of ground water level. Conclusively, the vacuum consolidation shows 3-dimensional behaviors and pore water pressure reaches a negative value in a short time. In addition, it is expected to have a comparatively good consolidation effect using non -woven board, and vacuum loading results in increasing the shear strength at the bottom and top of call layers.

  • PDF

Model Tests on the Bearing Capacity and Settlement of Footing Considering Scale Effect (Scale Effect를 고려한 기초의 지지력 및 침하량 산정을 위한 모형실험)

  • 정형식;김도열;김정호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.343-354
    • /
    • 2003
  • The scale effect should be considered to determine the bearing capacity and settlement of footings from Plate-Load Test, because of the size difference between a footing and a loading plate. To analyze characteristics of bearing capacity and settlement according to the difference of loading plate sizes, model tests were performed with four different sizes of square plate, which are B=10, 15, 20 and 25cm, on five different kinds of subsoil. Based on the analyzed results, this paper also proposes a method of bearing capacity and settlement determination, where scale effect is considered depending on the mixing ratio of sand and clay. Until now, uneconomic constructions have been conducted because of unreasonable evaluation in estimating bearing capacity and settlement of footings from Plate-Load Test in fields. In the application of the formula proposed in this research to field problems, it is expected that evaluation of bearing capacity and settlement of footings can be more reliable and more economic construction can be achieved.

A Study of Characteristics of Soil-Pile-Structure Interaction Behavior on the Frequency Contents of the Seismic Waves (지진파의 주파수 특성에 따른 지반-말뚝-구조물 상호작용계의 거동 특성 분석)

  • 이종우;이필규;김문겸;김민규
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.3
    • /
    • pp.295-308
    • /
    • 2004
  • In this study, several Soil-Structure-Interaction (SSI) analyses were performed using the developed FE-BE coupling method and the seismic response behavior of the structure's systems was determined. For the verification of the fundamental solution which is used in this analysis method, a dynamic analysis of the homogeneous ground was performed and it was compared to the results of Estorff et al. In order to verify the seismic response analysis, the results are compared with those of another commercial code. Several kindd of SSI analyses were performed and the seismic response associated with the rile foundation, seismic waves and a consideration of the ground nonlinearity were determined. As a result, it was found that the pile foundations didn't greatly helpful during the seismic event.

Verifications of the Impact-echo Technique for Integrity Evaluations of the Drilled Shaft Using Full Scale Tests (현장시험에 의한 충격반향기법의 말뚝 건전도 검사 적용성 평가)

  • Jung Gyungja;Cho Sung-Min;Kim Hong-Jong;Jung Jong-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.207-214
    • /
    • 2005
  • The reflected signals from the defects of a pile and the boundaries between the pile and soils are analyzed to evaluate the integrity of drilled shafts in the impact-echo test. Signals varied according to both of the stiffness ratio of the pile to defects and that of the pile to surrounding soils. Model tests using the small size pile in the laboratory and numerical analyses have limitations in finding the characteristics of the signals due to different stress wave characteristics and unreliable modelling for the interaction between the pile and soils respectively. Full scale testing piles which have artificial defects are installed by the actual construction method and they were used to investigate the characteristics of reflected signals according to defects and the stiffness ratios of the pile to soils around.

A Study on the Properties of Grout Materials Based on Cement Type (시멘트계 주입재의 주입특성에 관한 연구)

  • 천병식;최중근
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.229-236
    • /
    • 2002
  • In this study, the characteristics of chemical grouting, such as solidification, penetrability, were analyzed experimentally by grain size of grout materials and permeability, relative density of the ground. For evaluating applicability of grout material, solidification tests and permeability tests were peformed. From the results of the tests, effective solidification ratio and penetrability ratio of Micro Cement were 75% and 86% respectively when ground permeability was in the range of 10$^{-4}$ to 10$^{-2}$cm/sec. On the other hand, effective solidification ratio and penetrability ratio of Ordinary Portland Cement (OPC) were both lower than 50%. When penetrability of grout material is needed for improvement of dam foundation and soft ground, application of Micro Cement is much superior to that of the other materials. The results of the grouting tests in the hydrodynamic ground show that the solidification effect of long gel-time grout material is excellent as injection pressure increases when groundwater velocity is relatively low. But when groundwater velocity is relatively high, the solidifcation effect of long gel-time grout material is very poor because most grout materials are outflowed.

Analytical study on resisting moment of concrete pole installed in sloped ground (콘크리트 전주의 경사지 저항 모멘트에 관한 해석 연구)

  • Shin, Dong-Geun;Lee, Seung-Ryun;Yi, Gyu-Sei;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.842-847
    • /
    • 2007
  • In this study, for the purpose of estimating the resisting moment of sloped ground based on level ground fall down safety equation in design specification, compute it depends on penetration depth of concrete pile applying modulus of foundation about the angle of internal friction, cohesion, unit weight of soil, classes of the ground, sandy or clay soil, and verify established study using L-Pile Plus13.8. Also, select four cases that characteristics of soil depending on the soil grade is considered and compute the 12m length concrete pile's resisting moment of the ground those angle is changing from $0^{\circ}{\sim}35^{\circ},\;step\;5^{\circ}$. In the result, identify that the resisting moment of ground decreases depending on ground slope. Thus, increasing of penetration depth is required.

  • PDF

Estimation of the Depth of Embedded Sheet Piles Using Two Types of Geophysical Loggings (다종 물리검층을 통한 시트파일 근입 심도 추정 연구)

  • Hwang, Sungpil;Kim, Wooseok;Jeoung, Jaehyeung;Kim, Kiju;Park, Byungsuk;Lee, Chulhee
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.525-534
    • /
    • 2022
  • This investigation used two different geophysical logging techniques to confirm the depth to which a sheet pile was driven. Depth was estimated through analysis of the movement speed and three-component movement directions of a P-wave transmitted through the ground. It was also estimated by pole-pole and pole-dipole methods using electrical data logging to measure apparent resistivity. The two methods' respective results were 9.0 m (±1.5 m) and 7.5 m. As field ground conditions will include mixtures of various materials, electrical data logging is judged to be suitable for assessing depth due to its low signal-to-noise ratio.

A Study on the Bearing Capacitiy behavior of Large-diameter Drilled Shafts According to Various Ground Conditions under Pile Tip through Numerical Analysis Results (수치해석 결과 분석을 통한 다양한 말뚝 선단하부의 지반조건에 따른 대구경현장타설말뚝의 지지력 거동에 관한 연구)

  • Kim, Chae Min;Yun, Do Kyun;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.11
    • /
    • pp.7-22
    • /
    • 2021
  • In this study, inverse analysis was performed on the bi-directional axial compressive load test conducted on drilled shafts. And the bearing capacities were analyzed by numerical analysis of various pile tip ground conditions of silt clay, silt sand, sand silt, sand gravel, weathered rock, and soft rock. The bearing capacities were analyzed using the P-S method, the Davisson method, and the allowable sttlement of 25.4 mm. The minimum allowable bearing capacities analyzed by three methods were found to be 19.64 MN ~ 24.96 MN. At this time, the base resistances were sharing a 2% ~ 12% of a head load, shaft resistance were shared 88% ~ 98% of the head load. The greater the strength of pile tip was found to increase the allowable bearing capacity. However, the difference between the maximum allowable bearing capacity and the minimum allowable bearing capacity was 5.32 MN, and the increase in the allowable bearing capacity was only 27% depending on the pile tip.

Estimation of Absorbing Capacity from Rockfall Protection Fences (도로 낙석방지울타리의 낙석지지능력 평가 연구)

  • Hwang, Young-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.4
    • /
    • pp.59-66
    • /
    • 2002
  • Designs for rockfall protection systems must consider rock and soil types, the angle of the slope, conditions on top and the toe of the affected area. Rockfall protection fence is installed to block for falling rock from cut slopes and this is one of the most common rockfall protection measures. The capability of the fence is provided that sum of capability of poly vinyl chloride coated wire mesh, steel support and wire rope respectively. But in some case, the rockfall protection fence was not supported rockfall energy less than total capability of the fence through the full scale rockfall tests. Therefore, the objectives of this paper are to indicate the problems of fence capability and to improve the design specifications for the fence.

  • PDF

An Interdisciplinary Study on the Scour Depth Estimation of Incheon Bridge (인천대교의 세굴심 산정을 위한 다학제적 연구)

  • Yeo, Woon-Kwang;Lee, Hoon;Kim, Jeong-Hwan;Kwak, Moon-Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.562-566
    • /
    • 2006
  • 최근 들어 국내에서는 도서지방을 잇는 연육교와 해상구간을 통과하는 대형교량의 건설이 활발히 진행되면서 해상조건에서 발생하는 교량세굴에 대처하기 위한 연구의 중요성이 대두되고 있다. 그러나 아직까지 해상조건의 세굴현상을 파악하기 위한 적절한 세굴평가 기준이 제시되어 있지 않고 대부분 자연 하천교량 기준에 의해 해상교량의 세굴평가가 이루어지고 있는 실정이다. 교량에서 발생하는 세굴 현상은 교량 기초의 안정성에 치명적인 영향을 줄 수 있고 나아가서는 교량의 붕괴 원인이 될 수 있다. 또한 교량기초 지반의 지지력 부족이나 적정피복두께 결여 등의 원인으로 구조적인 문제점을 초래할 수 있다. 해상교량의 경우에는 조석에 의한 왕복류, 파 흐름의 상호작용, 점착성 지반 등 세굴에 영향을 미칠 수 있는 요인들이 복합적으로 작용하므로 교량 건설 전부터 해상조건을 반영한 다각적인 세굴검토가 요구된다. 본 연구는 강한 조석류가 작용하고 넓은 조간대를 형성하고 있는 인천대교의 세굴심을 합리적으로 산정하기 위하여 다학제적인 연구를 시도한 것이다. 본 연구에서는 해상조건의 침식유발특성을 파악하기 위한 연구로서 수치모형 및 수리모형 실험을 수행하고, 지반종류에 따른 침식저항능력을 파악하기 위한 세굴률 실험을 수행하였다. 더불어 인천대교 건설현장에 타설되어 있는 대구경 시험말뚝에 대한 실시간 세굴모니터링을 실시하여 얻은 현장관측 자료를 검증자료로 사용함으로써 종합적인 세굴검토를 통하여 다학제적이고 합리적인 해상교량의 세굴심을 평가하고자 한다.

  • PDF