• Title/Summary/Keyword: 지만 헬륨-네온 레이저

Search Result 3, Processing Time 0.015 seconds

I2-Saturated Absorption Spectroscopy for Frequency-Stabilization of He-Ne Laser at 543 nm (543 nm 헬륨네온 레이저의 주파수 안정화를 위한 I2 포화흡수분광)

  • Kim, Kyung-Chan;Eum, Nyeon-Sik;Hong, Joo-Hyun;Seo, Ho-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.859-865
    • /
    • 2010
  • We have designed and assembled a saturated absorption-spectroscopy system of $^{127}I_2$ for the frequency stabilization of the 543 nm He-Ne laser. The frequency of a internal-mirror 543 nm He-Ne laser was swept by utilizing the temperature and PZT change of the laser cavity length. Frequency modulation was applied to the output laser mirror with a PZT modulator for the third harmonic signal. A portion of the hyperfine spectrum originated from the R(12)26-0 and R(106)28-0 transitions of the B-X system of $^{127}I_2$ was observed as the third-derivative signal using a saturated absorption spectroscopy. The signal-to-noise ratio of a typical hyperfine spectrum signal was estimated to be 30:1.

Improvement of Measurement Accuracy for Absolute Height by Using Two Types of Doppler and Heterodyne Optical Interferometry (도플러방식과 헤테로다인 방식의 광간섭법을 병용한 절대높이 측정 정밀도 향상)

  • Ahn, Geun-Sik;Jhang, Kyung-Young;Moon, Heui-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.128-135
    • /
    • 1996
  • This paper proposes a high precision measurement technique to obtain the height of gage block with a few millimeter height. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, in the second step, heterodyne laser interferometry is adopted to acquire the precision value. A new kind of phase detector is constructed in the low cost for the heterodyne interferometer and its linearity with ${\pm}1%$ is confirmed by experiment. Also measurement error factors due to enviroments are discussed and methodology to reduce such errors is proposed. Preliminary experiments are carried out for the gage blocks of as high as a few millimeter.

  • PDF

Offset Frequency Stabilization of He-Ne Lasers Using Phase Locked Loop (PLL을 이용한 헬륨-네온 레이저의 옵셋 주파수 안정화)

  • Yun Dong Hyun;Suh Ho Sung;Lyou Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.496-501
    • /
    • 2005
  • This paper presents experimental results of the frequency offset locking of He-Ne lasers and the stability analysis. The master laser is free running, and the slave laser is a single-mode operating laser. The frequency difference of two lasers is stabilized to 200 MHz which can be synchronized using PLL servo. The measured beat frequency between two lasers was 200.004 MHz ${\pm}$ 0.15 MHz. The square root of Allan variance as a measure of stability in time domain is also measured. The long-term stability of the beat was worse than sort-term stability. With a gate time $\tau=1000\;s$, the square root of Allan variance was about 1 GHz. The results of the square root of Allan variance of the stabilized beat signal was a gate time of $\tau=1000\;s$, the square root of Allan variance was about 1.5 kHz. The long-term stability was improved by more than several hundred times compared with that without the stabilization.