• Title/Summary/Keyword: 지르코니아 지대주

Search Result 45, Processing Time 0.017 seconds

Implant-supported fixed prosthetic restoration using a high performance polymer (PEKK) in a mandibular unilateral resection: A case report (하악골 편측 절제 환자에서 High Performance Polymer (PEKK)를 이용한 임플란트 지지형 고정성 보철 수복 증례)

  • Kong, Dae-Ryong;Min, Gyeong-Won;Jang, Ki-Yeol;Lee, Gyeong-Je;Lee, Sun-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.254-262
    • /
    • 2022
  • When treating partial edentulous patients, it is important to use an appropriate restorative materials. Inappropriate restorative materials can adversely affect the outcome of prosthetic restorations. Zirconia and dental metal, which are currently and widely used materials, have a higher elastic modulus than cortical bone, so when an external force is generated, a harmful force can be applied to the implant and the bone around the implant. Polyetherketoneketone (PEKK), a recently introduced material, has a elastic modulus similar to that of cortical bone, and has many advantages in terms of physical properties and biocompatibility. This case report describes that implant-supported fixed prosthetic treatment using PEKK was performed, and functional and esthetic satisfactory results were obtained.

Stress distribution in implant abutment components made of titanium alloy, zirconia, and polyetheretherketone: a comparative study using finite element analysis (티타늄 합금, 지르코니아, 폴리에테르에테르케톤 지대주 재질에 따른 임플란트 구성요소의 응력분포: 유한 요소 분석을 통한 비교 연구)

  • Sung-Min Kim
    • Journal of Technologic Dentistry
    • /
    • v.46 no.2
    • /
    • pp.21-27
    • /
    • 2024
  • Purpose: This study aimed to analyze the stress distribution and deformation in implant abutments made from titanium (Ti-6Al-4V), zirconia, and polyetheretherketone (PEEK), including their screws and fixtures, under various loading conditions using finite element analysis (FEA). Methods: Three-dimensional models of the mandible with implant abutments were created using Siemens NX software (NX10.0.0.24, Siemens). FEA was conducted using Abaqus to simulate occlusal loads and assess stress distribution and deformation. Material properties such as Young's modulus and Poisson's ratio were assigned to each component based on literature and experimental data. Results: The FEA results revealed distinct stress distribution patterns among the materials. Titanium alloy abutments exhibited the highest stress resistance and the most uniform stress distribution, making them highly suitable for long-term stability. Zirconia abutments showed strong mechanical properties with higher stress concentration, indicating potential vulnerability to fracture despite their aesthetic advantages. PEEK abutments demonstrated the least stress resistance and higher deformation compared to other abutment materials, but offered superior shock absorption, though they posed a higher risk of mechanical failure under high load conditions. Conclusion: The study emphasizes the importance of selecting appropriate materials for dental implants. Titanium offers durability and uniform stress distribution, making it highly suitable for long-term stability. Zirconia provides aesthetic benefits but has a higher risk of fracture compared to titanium. PEEK excels in shock absorption but has a higher risk of mechanical failure compared to both titanium and zirconia. These insights can guide improved implant designs and material choices for various clinical needs.

Fabrication of definitive complete-arch implant-supported fixed prosthesis in upper and lower completely edentulous patient using temporary prosthesis scan: a case report (상하악 완전 무치악 환자에서 임시 보철물 스캔을 이용한 일체형 임플란트 지지 고정성 보철물 수복 증례)

  • Seung-Mi Jeong;Hyun-Lak Son;Kang-Duck Choi;Byung-Ho Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.243-252
    • /
    • 2024
  • When fabricating definitive implant-supported fixed prostheses in upper and lower completely edentulous patients, it is crucial to get information about the vertical dimension, jaw relationship, implants, abutments and gingival contour. In this case, temporary prostheses were used to take the information. The temporary prosthesis was scanned outside of the mouth so that it increased the efficiency of scanning it. During the scan of the prosthesis, a scan zig which connected both posterior parts of the prosthesis was used to minimize the scan errors. We report this case because we obtained satisfactory functional and esthetic results by using the digital technology.

Aesthetic implant restoration with alveolar bone graft and digital method on maxillary central incisor: a case report (치조골이식과 디지털 방법을 활용한 상악 중절치 임플란트 심미 수복 증례)

  • Jang, Han-Sol;Pyo, Se-Wook;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.168-174
    • /
    • 2022
  • In case of gingival recession or bone defect in maxillary anterior implant treatment, it is not easy to obtain satisfactory clinical results. In this case, loss of the labial alveolar plate was diagnosed in the maxillary right central incisor, so after tooth extraction, soft tissue was secured and implant placement with bone graft was planned. In addition, digital guide surgery was performed for the ideal implant position, and GBR (Guided Bone Regeneration) was accompanied with the xenogeneic bone and the autologous bone collected from the mandibular ramus since alveolar bone defects were extensive. After a sufficient period of osseointegration of the implant, a temporary prosthesis was fabricated through secondary stage surgery and impression taking, and through periodic external adjustment, the shape of soft tissue was improved. In the final prosthesis fabrication, a color tone of natural teeth was induced by an gold anodized customized abutment, and an aesthetic and functional zirconia prosthesis with reproducing the shape of the temporary prosthesis through intraoral scan was delivered.

Oral rehabilitation of a patient with collapsed occlusal plane resulting from loss of posterior teeth (구치부 상실로 인해 교합 평면이 기울어진 환자에서 임플란트를 이용한 구강 회복 증례)

  • Jinwoo Han;Jae-Seung Chang;Se-Wook Pyo;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.165-173
    • /
    • 2024
  • Restoring lost teeth is very important in terms of both function and aesthetics. If tooth loss occurs in the posterior region and the loss of support is persistent, it may cause a gradual shift in the position of the mandible and a change in occlusion. This clinical case attempted to restore support for the posterior teeth with a fixed prosthesis using implants in a patient whose opposing teeth were erupted and the occlusal plane collapsed due to long-term loss of the maxillary left posterior teeth and mandibular right first molars. To correct the occlusal plane of remaining dentition, wax-up of maxillary left posterior teeth was duplicated with acrylic resin and placed on maxilla. Surgical template for implant placement were fabricated using digital technology. After the support of the posterior teeth was restored with the placement of the implant, stable occlusion with temporary restorations was observed for a sufficient time. Afterwards, monolithic zirconia prosthesis was placed on the patient to ensure functional and aesthetic improvement.