• Title/Summary/Keyword: 지구 전류

Search Result 129, Processing Time 0.027 seconds

Electrical Anisotropy of the Okchon Belt Inferred from Magnetotelluric Data (자기지전류 탐사 자료에 나타나는 옥천대의 전기적 이방성 구조)

  • Lee, Choon-Ki;Lee, Heui-Soon;Kwon, Byung-Doo;Cho, In-Ky;Oh, Seok-Hoon;Song, Yoon-Ho;Lee, Tae-Jong
    • Journal of the Korean earth science society
    • /
    • v.28 no.2
    • /
    • pp.227-239
    • /
    • 2007
  • The MT data at the Okchon Belt show peculiar phase responses exceeding $90^{\circ}$. A reasonable explanation is that those responses are due to an electrical anisotropy structure which is composed of a narrow anisotropic block and an anisotropic layer. Considering the dominant anisotropic strikes of the block (NE-trend) and the layer (NW-trend) inferred from the MT data, if existing, the electrical anisotropy in the Okchon Belt was probably produced by the deformations in the pre-Jurassic period, since the NE-trending shearing or thrusting should create alternating bands of metamorphic rocks and fractures with NE-trending. Correlation of the structural strike of 2-D block with the latest EW-trending deformation events demonstrates that the geometrical structure of the anisotropic block was formed by the latest Daebo and Bulgugsa orogeny.

A Study on the Resistivity Structure in Central Myanmar Basin using DC Resistivity and Magnetotellurics (전기비저항 탐사와 자기지전류 탐사 자료를 이용한 미얀마 중앙분지 전기비저항 구조 연구)

  • Noh, Myounggun;Lee, Heuisoon;Ahn, Taegyu;Jang, Seonghyung;Hwang, InGul;Lee, Donghoon;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.2
    • /
    • pp.62-71
    • /
    • 2019
  • We conducted DC resistivity and MT survey to obtain the resistivity structure of the central Myanmar basin. We tried to analyze the underground structure through the resistivity variation of Myanmar by performing representative geophysical survey methods because researches on the electrical resistivity structure are insufficient in Myanmar. The electrical resistivity is expected to be low considering the marine sedimentary rocks composed of shale and sandstone in this area. The DC resistivity and MT survey were carried out using SmartRho of Geolux Co., Ltd. and MTU-5A of Phoenix geophysics Ltd., respectively, to visualize the electrical resistivity structure of study area. DC resistivity and MT survey showed an electrical resistivity less than dozens of ohm-m within the depth of 100 m. In particular, MT survey data were almost similar to TM and TE modes in the frequency range above 1 Hz. The two-dimensional inversion of MT data showed a subsurface structure with low resistivity below 150 ohm-m divided into east-west direction. We confirmed that the inversions of DC resisitivity and MT data along an overlapped survey line represented similar results. In the future, considering the high electrical conductivity, it would be effective to perform DC resistivity and MT survey simultaneously to study the electrical resistivity structure of the central Myanmar basin.

Implementation of a Power Simulator for Energy Balance Analysis of a LEO Satellite (저궤도 위성의 에너지 균형 분석을 위한 전력 시뮬레이터의 구현)

  • Jeon, Moon-Jin;Lee, Na-Young;Kim, Day-Young;Kim, Gyu-Sun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.176-184
    • /
    • 2010
  • The power simulator for a LEO satellite is a useful tool to analyze mission validity and energy balance for various mission scenarios by estimating power generation, power consumption, depth of discharge, bus voltage, charging/discharging current, etc. In this paper, it is described the calculation algorithm of the solar array (SA) power, the satellite load power and the battery modeling method to develop a satellite power simulation. To simulate the SA power generation, three different operation modes (DET, MPPT, CV) of SAR (Solar Array Regulator) are considered with a SA model. The satellite load power is estimated using the satellite unit power database, the unit on/off configuration at some satellite operation modes. The bus voltage and battery charging/discharging current at the specific DoD (Depth of Discharge) are calculated based on the battery characteristics. By this satellite power simulator, it can be conveniently analyzed the energy balance and the validity of a planned mission of a LEO satellite.

Geophysical Study on the Geoelectrical Structure of the Hwasan Caldera in the Euisung Sub-basin Using Magnetotelluric Survey (자기지전류 탐사를 이용한 의성소분지 화산 칼데라의 지구물리학적 연구)

  • Yang, Jun-Mo;Kwon, Byung-Doo;Cho, In-Ky;Lee, Heui-Soon;Park, Gye-Soon;Um, Joo-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.99-108
    • /
    • 2008
  • To extend our detailed knowledge for the Hwasan caldera, we carried out magnetotelluric (MT) survey, which is pretty sensitive to electrical property variation in both horizontal and vertical direction of subsurface, across the Hwasan caldera with the direction of EW. The 2-D inversion results of observed MT data lead to following conclusions. Firstly, the depth of the basin basement inferred by the MT inversion results matches well with that suggested by previous potential studies, but the basement resistivity seems fairly low when compared to that of general case. This feature might be related with the large-scaled, highly conductive layer beneath the Euisung Sub-basin suggested by the previous MT study. Secondly, the high resistivity zones reaching to 4000 $\Omega{\cdot}m$ are imaged around two external ring fault boundaries. These zones are thought of as the response of the rhyolitic dykes intruding along the ring fault, and in the previous gravity data correspond to relatively high density anomalies. Thirdly, low resistivity zone reaching to 200 $\Omega{\cdot}m$ is detected around a depth of 1km beneath the central part of the caldera, which has not been yet reported in korean geophysical literatures. If we take account of the evolution model of the Hwasan caldera, this zone is regarded as the past sedimentary layer that subsided during the period of forming external ring fault system. In addition, the relatively low density anomaly observed in the central part of the caldera may be attributed to this sedimentary layer.

A Study of 3D Ore-Modeling by Integrated Analysis of Borehole and Geophysical Data (시추자료와 물리탐사자료의 복합해석을 통한 3차원 광체 모델링 연구)

  • Noh, Myounggun;Oh, Seokhoon;Ahn, Taegyu
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.257-267
    • /
    • 2013
  • 3-D ore modeling was performed to understand the configuration of ore bodies by integrated analysis of borehole and geophysical data in iron-mine area. Five representative indices of rocks were designated, which were obtained from geological survey and borehole. The five indices of rocks were geostatistically simulated by Sequential Indicator Simulation method to delineate boundary of the ore bodies. And Ordinary Kriging and Sequential Gaussian Simulation was applied to make secondary information using resistivity data from magnetotellurics and DC resistivity survey, and this information was used for simple kriging with local varying means, one of integrated kriging techniques. From the correlation analysis between each properties, it was found that high grade of ore is characterized by increased density, whereas the electrical resistivity decreases. With the integrated results of geophysical and borehole data, it was also found that the real configuration of ore body was similar to the modeled result and information about ore grade in 3-D space was obtained.

파워디바이스의 저 Noise화 동향

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.269
    • /
    • pp.66-72
    • /
    • 1999
  • 전력$\cdot$교통$\cdot$산업$\cdot$정보$\cdot$가전의 각 분야에서 파워일렉트로닉스를 지탱하는 소자로서 파워디바이스가 하는 역할은 매우 크다. 특히 최근에는 지구온난화대책으로서 $CO_2$의 배출규제와 화석에너지 고갈에 대한 대응이 요구되고 있다. 이를 해결하기 위해 각종 전기기기 분야에서는 파워일렉트로닉스를 활용한 산업용 모터의 제어와 에어컨$\cdot$냉장고 등의 자에너지, 그리고 환경보호를 위한 전기자동차의 보급, 태양광발전과 풍력발전 등의 신에너지의 개발이 활발해지고 있다. 이와 같이 파워일렉트로닉스의 발전은 사회에 커다란 혜택을 가져다주었으나 동시에 전원의 고조파와 EMC(Electro-Magnetic Compatoboloty)문제를 초래하고 있다. 고조파 문제에 대해서는 액티브필터용 IPM(Intelligent Power Module)등의 등자으로, 기기측에서 적극저긍로 대책을 강구하고 있으나, 한편 EMC의 대응은 고조파대책에 비하여 다소 어려움이 이TDj 업계 전체적으로는 이제야 대응이 시작된 단계이다. 최근 파워디바이스의 주류가 된 IBT(Insulted Gate Bipolar Transister)는 고속성과 저포화전압이 인정되었으나 IGBT가 갖고 이쓴 고속 Switching 특성 때문에 EMC대응이 문제가 되고 있다. 따라서 IGBT자신의 특성개선은 물론 환류다이오드의 회복전류의 소프트화, 패키지의 개량, IGBT의 신구동방식의 개발 등, 파워디바이스 전체적으로 EMC에의 대응이 시작되었다.

  • PDF

Study of Electrodynamic Repulsion Force on Contact of EV-Relay (EV-Relay의 접점에서 발생하는 전자반발력 연구)

  • An, Jung-Sik;Joo, Hyun-Woo;Park, Hong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.914-915
    • /
    • 2011
  • 최근 지구온난화의 문제점으로 저 탄소 친환경 자동차로 배터리 전력과 가솔린 엔진을 같이 사용하는 하이브리드 자동차가 주목 받고 있다. 최근에 개발되고 있는 하이브리드 자동차는 전력의 효율적인 사용을 위해 배터리의 전압이 증가되고 있고 이에 따라 DC High Voltage를 다룰 수 있는 Relay의 용량이 요구된다. 이런 측면에서 하이브리드 자동차에 사용되는 EV-Relay의 경우 소형화에 따른 문제점이 발생한다. 그 대표적인 문제점으로 EV-Relay의 접점에 일시적인 과전류가 흐르면서 전기적 반발력이 발생하여 EV-Relay의 폭발과 같은 위험한 문제점이 발생 할 수 있다. 이에 따라 본 논문에서는 Relay에서 발생하는 전기반발력의 힘을 MAXWELL프로그램을 통해 모의하는 연구를 하였다.

  • PDF

아리랑 1호 임무운영 결과

  • 박선주;김해동;이기순;김은규;최해진
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.99-99
    • /
    • 2003
  • 우리나라 최초의 실용급 지구관측위성인 아리랑 1호는 지난 2003년 2월 21일부로 목표로 하였던 임무운영기간 3년을 완수하였다. 아리랑 1호의 정상 임무운영에 사용되는 탑재체는 전장광학카메라, 해양관측카메라, 그리고 우주과학 탑재체이며, 2001년 8월 원인을 알 수 없는 과전류 발생으로 임무가 중단된 우주과학 탑재체를 .제외한 나머지 탑재체들은 임무 운영기간동안 정상적으로 운영되었다. 전자광학카메라는 한반도를 비롯한 전 세계를 대상으로 지리정보를 위한 영상자료를 획득하는 것이 목적이었으며, 해양관측카메라는 생물학적 해양지도 및 해양환경 관측을 위한 자료를 획득하는 것이다. 우주과학 탑재체는 고에너지 전하입자에 의한 Single Event Upset현상, 우주방사능 관측, 그리고 전자의 온도 및 밀도 측정이 주요 목표였다. 당초 목표했던 임무운영기간을 초과한 현재(2003년 7월 1일 기준)까지 우주과학 탑재체를 제외한 나머지 탑재체들은 정상적으로 운영되고 있다. 본 논문은 아리랑 1호 발사 후 약 3년 6개월간의 기간동안 수행된 탑재체 운영결과들을 정리하였다.

  • PDF

고효율 무정전전원장치

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.291
    • /
    • pp.72-75
    • /
    • 2001
  • 정보네트워크산업이 급속히 발전, 보급되는 가운데 그 전원인 무정전전원장치(Uninterruptible Power Supply: UPS)에 대해서도 여러 가지 요구가 나오고 있다. 특히 최근에는 고신뢰성화$\cdot$소형화$\codt$저가격화에 더하여 러닝코스트 저감과 지구온난화 방지를 연결한 개념의 성에너지화를 목적으로 하는 전력변환효율의 향상에 대한 요구가 강해지고 있다. 이번에 이러한 요구에 응하기 위하여 미쓰비시전기는 상시상용 급전방식을 채용하여 HSS(High Speed Switch)회로와 쌍방향 컨버터회로를 개발하여, 고효율이며 급전신뢰성이 높은 MPC(Multiple Power Compensator)방식의 UPS를 개발하였다. 이에 의하여 전력변환효율을 90$\%$에서 98$\%(100kVA에서)로 대폭 개선함과 동시에 종래의 상용급전방식 UPS의 결점이었던 상용전원 이상시의 급전계통 전환시간을 부하기기에 영향을 미치지 않는 2밀리초까지 단축시켜 전환시에도 순간 단전됨이 없이 부하급전을 계속할 수 있도록 하였다. 또한 통상의 급전시에는 쌍방향 컨버터에 입력전류가 고조파보상기능을 갖게 하여 입력역률 0.99를 달성하였다.

  • PDF

The Design and Implementation of 3[kW] Sollar Cell PWM Inverter (3[kW]급 태양광 인버터의 설계 및 구현)

  • Song, Y.U.;Oh, S.C.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.75-77
    • /
    • 2008
  • 석유를 포함한 자원고갈과 지구온난화와 같은 환경문제로 인하여 자연에너지를 이용한 소규모 태양광발전이 각광을 받고 있다. 본 논문에서는 web상에서 모니터링이 가능한 3[kW]급 태양광 발전 인버터의 설계 및 구현방법을 제시한다. 설계된 인버터는 독립형이며, Boost Converter를 이용하여 350[Vdc]를 400[Vdc]로 승압한 이후 SPWM 방식을 이용하여 교류 파형을 얻어낸다. LC 필터를 통과한 출력파형은 실효치 220[Vac], 주파수는 60[Hz]의 상용전원이고, THD는 5% 이하이다. 또한 350[Vdc]의 10% 레벨에서는 Boost Converter의 Duty를 자동 조정하여 출력단의 전압을 400[Vdc]로 유지할 수 있는 기능을 포함한다. 또한, 출력단의 전압과 전류를 센싱한 후, PC에서의 모니터링 시스템을 구축하였다. 이를 통해 인버터에 포함된 PC를 서버로 활용하여, LAN이 가능한 곳에서는 인버터의 상태와 발전량을 알 수 있다.

  • PDF