Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy (지열을 이용한 코일 침적형 히트펌프의 성능 특성)

  • Oh, Hoo-Kyu;Lee, Dong-Gun;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.437-444
    • /
    • 2012
  • This paper describes the experimental characteristics on cooling and heating performance of the coil deposition type heat pump using geothermal energy to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling degree, evaporation and condensation temperature in the coil deposition type heat pump using geothermal energy. The main results are summarized as follows : As the evaporation temperature and subcooling degree of the coil deposition type heat pump using geothermal energy increases, and the condensation temperature decreases, the COP of this system increases. The subcooling degree, evaporation and condensation temperature of the coil deposition type heat pump have an effect on cooling and heating COP of this heat pump. Therefore, it is a necessary to determine the optimum operation conditions for the highest COP of this heat pump presented in this study.

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

Sensitivity Analysis for Tank Model's Parameters by Applying Potential Evapotranspiration Equations (잠재증발산식 적용에 따른 Tank 모형 매개변수 민감도분석)

  • Rim, Chang-Soo;Lim, Ga-Hui;Lee, Won;Kim, Jung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.358-358
    • /
    • 2012
  • 최근 기후변화의 영향에 따라 강수량과 증발산량이 변하는 경향을 보이고 있으며, 그에 따라 유출량도 변하고 있다. 따라서 기후변화가 수자원에 미치는 영향도 커지고 있으며, 댐 유역의 유출량 산정은 홍수나 용수의 확보측면에서 중요시 되고 있다. 탱크모형은 일본의 Sugawara가 1961년 처음 개발한 모형으로 유역을 오리피스 유출공을 가진 저류형 수조의 조합으로 가정하여 유량을 산정하는 유출모형으로 매개변수가 많고, 이들을 시행착오로 결정해야 하기 때문에 숙련된 경험이 요구되는 단점이 있으나 계산법이 명확하고 수문현상을 잘 재현한다는 장점이 있다. 탱크에는 강수량, 유출량, 그리고 증발량과 같은 입력 자료가 필요하며, 정확한 실제 증발산량 값을 알기는 어렵기 때문에 물수지를 이용해 증발산량을 계산하여 사용하고 있지만 유출량 미계측 지역에서는 사용이 어렵다. 그러므로 태양복사에너지, 온도, 바람, 기압, 습도와 같은 기상학적 인자에 따라서 잠재증발량을 산정하여 탱크 모형의 입력 자료로 사용한다면, 유출량자료가 없는 유역에서도 탱크모형을 사용하여 유출량을 산정할 수 있을 것으로 사료된다. 본 연구에서는 섬진강댐유역과 합천댐유역의 유출량 산정을 위해 잠재 증발산량 산정식(Penman, FAO P-M, Makkink, Preistley-Taylor, Hargreaves)을 적용하여 Tank 모형 매개변수들의 민감도분석을 수행하였다. 섬진강댐은 전북 임실군 강진면 옥정리와 정읍시 산내면 종성리 사이에 있으며, 유역면적은 $763km^2$, 댐 높이는 64m, 제방길이 344.2m 댐으로 매개변수 민감도 분석 적용기간은 1975년~1992년이다. 합천댐은 경상남도 합천군 대병면 회양리에 있는 댐으로 높이 96m, 길이 472m, 유역면적 $925km^2$의 다목적 댐이며, 매개변수 민감도 분석 적용기간은 1989년~1999년이다.

  • PDF

Effects of Storage Gas Concentrations on the Transpiration Rate of Fuji Apple during CA Storage (CA저장 기체조성에 따른 사과 Fuji의 증산속도)

  • 강준수;정헌식;최종욱
    • Food Science and Preservation
    • /
    • v.9 no.3
    • /
    • pp.261-266
    • /
    • 2002
  • A transpiration model was selected and tested experimentally to predict transpiration into of Fuji apple stored in a normal air and controlled atmospheres (l∼3% O$_2$+ l∼3% CO$_2$) at 0$\^{C}$ and 98% RH for 6weeks. CA storage decreased the respiration rate of Fuji apple by 50% when compared with normal air storage. The transpiration rates of apple showed 50∼70% higher in normal air storage than those in CA storage and were decreased by increasing CO$_2$concentration under same concentration of O$_2$. The transpiration rates estimated by the selected model were in good agreement with experimental data for Fuji apples under controlled atmosphere conditions and normal air. When the respiratory heat generation rate u of Fuji apple increased with storage conditions, the evaporating surface temperature and transpiration rate also increased. But since some portion of respiratory heat was used as latent heat in the evaporating surface, the change of u value had a little effect on the determination of the evaporation temperature and the transpiration rate.

Development of Pervaporation Module and Modelling of Feed Temperature Distribution in A Frame and Plate Type of Membrane Module (투과증발 막모듈의 개발과 판틀형 모듈 내에서의 온도 감소 현상에 관한 모델링)

  • 임지원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.03a
    • /
    • pp.111-125
    • /
    • 1996
  • 본 연구에서는 평판형 모듈 설계의 최적화를 목적으로 원액 흐름 조건에 따른 모듈내 원액 온도 및 유속 분포를 예측할 수 있는 모델식을 확립하고 전산모사(simulation)를 통해 흐름 조건들이 온도 분포에 끼치는 영향들을 조사하였으며 이들의 결과를 모듈설계에 반영하고자 하였다. 확립된 모델식의 타당성을 확인하기 위하여 최소한의 실험을 행하여 실험치와 모델치를 비교하였다. 또한 개발된 새로운 구조를 지니는 평판형 막모듈에 상용화된 막과 국내에서 개발된 막을 장착하여 모듈 내에서의 온도감소 현상을 실험적으로 비교하였다.

  • PDF

Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat (발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dong-Ho;Moon, Deok-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.470-476
    • /
    • 2010
  • The thermodynamic performance of closed ocean thermal energy conversion (OTEC) cycle with 1 MW gross power was evaluated to obtain the basic data for the optimal design of OTEC. The basic thermodynamic model for OTEC is Rankine cycle and the thermal effluent from power plant was used for the heat source of evaporator. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the temperature variation of thermal effluent. The saturated pressure of evaporator increased with respect to the increase of thermal effluent temperature, so the cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 1 MW gross power. As the thermal effluent temperature increases about $15^{\circ}C$, the cycle efficiency increased approximately 44%. So, it was revealed that thermal effluent from power plant is important heat source for OTEC plant. Also, if there is an available waste heat, it can be transferred heat to the working fluid form the evaporator through heat exchanger and cycle efficiency will be increased.

Verification of Land Surface Temperature using COMS(Communication, Ocean and Meteorological Satellite) (천리안 위성을 이용한 지표면 온도의 검증)

  • Baek, Jong-Jin;Choi, Min-Ha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.99-102
    • /
    • 2012
  • 지표면 온도는 토지피복의 상태, 식생의 분포 상태, 토양수분, 증발산 등의 영향으로 많은 차이를 가지게 되며, 지면-대기의 상호순환의 중요한 인자로써 기후모델 및 농업 등의 기본적인 데이터로 사용되고 있다. 이러한 지표면의 온도를 정확하게 파악하는 것은 수문학적 관점 및 기상적인 관점에서 매우 중요하다. 기존에 LST (Land Surface Temperature, 지표면온도), ET (EvapoTranspiration, 증발산), NDVI (Normalized Difference Vegetation Index, 정규식생지수) 등의 검증이 많이 이루어진 MODIS위성의 Terra/Aqua센서는 한반도를 스캔하고 지나갈 때의 순간적인 데이터를 산출된다. 공간적인 면에서는 많은 이점이 있으나 시간적인 면에서는 시간에 따른 인자들의 변동성을 파악 하는데는 많은 문제가 있다. 그렇기 때문에 시 공간적으로 변화양상을 측정 할 수 있는 정지궤도위성의 중요성이 대두되고 있다. 본 연구에서는 국내에서 2010년 6월 27일 발사된 정지궤도위성인 천리안의 데이터를 활용하였다. 천리안 위성은 기상 센서와 해양관측 센서 그리고 통신센서를 가진 위성이다. 천리안 위성의 기상 센서는 MTSAT-1 위성과 같은 적외선 센서를 탑재하고 있으며, 평시에는 15분 단위의 데이터를 산출하게 된다. 천리안에서 제공되는 많은 Product(강우강도, 해수면온도, 가강수량, 지구방출복사 등)는 수자원 및 기상에 관련된 데이터가 제공된다. 하지만 아직 검증이 많이 이루어지지 못하였다. 그래서 천리안 위성 데이터인 지표면 온도자료를 이용하여 천리안 위성의 효율성에 대해서 알아보고자 하며, 기존의 검증이 많이 이루어진 MODIS의 데이터와의 상관성을 분석하고 지상과의 관계를 검증 및 비교하여 천리안 위성의 활용성에 대해서 알아보려고 한다.

  • PDF

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s

Performance Analysis of an Ammonia(R717) and Carbon Dioxide(R744) Two-Stage Cascade Refrigeration System ($NH_3-CO_2$를 사용하는 이원 냉동 시스템의 성능 분석)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, cycle performance analysis of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the ammonia(R717) high temperature cycle and the carbon dioxide low temperature cycle. The main results were summarized as follows : The COP of two-stage cascade refrigeration system increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of two-stage cascade refrigeration system decreases with the increasing condensing temperature, but increases with the increasing evaporating temperature. And the COP of two-stage cascade refrigeration system increases with increasing the compressor efficiency. Therefore, superheating and subcoolng degree, compressor efficiency, and evaporating and condensing temperature of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system have an effect on the COP of this system.

Detailing of regional evapotranspiration using temperature data and energy balance method (기온 자료와 에너지수지 방법을 이용한 지역 기준 증발산량 상세화)

  • Shin Uk Kang;Wan Sik Yu;Kyoung Pil Kim;Yong Sin Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.118-118
    • /
    • 2023
  • 물순환 과정의 구성요소 중 하나인 증발산(증발과 증산)은 각종 수자원시설물의 운영관리, 수자원계획 수립, 농업용 시설의 개발 및 운영관리 등에 필요한 매우 중요한 요소이다. 한편, 기후변화 등으로 '14~'19년 장기간 가뭄, '17년 가뭄상황에서도 태풍 '차바'에 의한 국지적 홍수, '20년 역대 최장기간 장마에 의한 대규모 홍수, '22년 태풍 '힌남노' 이후 남부지역 극심한 가뭄 등 가뭄과 홍수가 반복되어 물관리 여건이 매우 어려운 상황이다. 이러한 홍수/가뭄에 효과적으로 대응하기 위해 강우-유출 모형을 사용한다. 신뢰적인 예측결과를 얻기 위해서는 상세하고 정밀한 증발산량 추정이 필요하다. Penman-Monteith(PM) 기법으로 기준 증발산량을 산정하기 위해서는 최고·최저기온, 이슬점온도, 풍속, 일조시간 등의 기상자료가 필요하다. 이러한 자료는 전국 95개 ASOS 지점에만 얻을 수 있다. 계산된 95개 지점의 기준 증발산량은 티센망 등 방법으로 공간평균하여 활용한다. 95개 지점 자료만으로는 지역적 기상 특성을 반영하여 기준 증발산량을 산정하는데 한계가 있으며, 결국 강우-유출분석의 신뢰도 저하로 귀결된다. 본 연구는 기상청 ASOS 지점 외 AWS 590개 지점을 추가하여 기준 증발산량을 산정하여 공간적으로 상세화하였다. ASOS 지점들에 대해 PM 기법과 Hargreaves(HS) 기법으로 22년간의 일단위 기준 증발산량을 각각 계산하였다. 이들의 상관계수는 평균 0.85로 매우 높아, HS 기법으로 산정된 AWS 지점 결과의 추가사용이 적정하였다. 기온만을 사용하는 HS 기법, PM과 HS의 상관성 및 풍속을 반영한 2가지 보정 HS 기법으로 기준 증발산량을 계산하여 비교·분석하였다. 보정된 HS의 결과가 기존 HS 기법에 비해 오차가 적고, 자료의 편향성이 줄어드는 등 더 좋은 결과를 나타내었다. 따라서, 각종 수문분석에 보정 HS 기법을 AWS 지점에 확대·적용하고, ASOS 관측소의 PM 기법과 병행해 상세화하여 활용하면 수문분석의 신뢰성을 더욱 높일 수 있을 것이다.

  • PDF