Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System (R744용 초임계 냉동사이클의 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2009
  • In this paper, cycle performance analysis for cooling capacity, compression work and COP of R744($CO_2$) transcritical vapor compression refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : The cooling capacity of R744 increases with superheating degree, but decreases with the increasing evaporating temperature and outlet temperature of gas cooler. The compression work increases with superheating degree and cooling pressure of R744, but decreases with the increasing evaporating temperature. And, The COP increases with outlet temperature and evaporating temperature of R744 gas cooler, but decreases with the increasing superheating degree. Therefore, superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

Concentration of Fermented Ethanol by Using Pervaporation System (투과증발 시스템을 이용한 발효에탄올 농축)

  • 안승호;장재화;유제강;이규현;고석문
    • Membrane Journal
    • /
    • v.7 no.2
    • /
    • pp.65-74
    • /
    • 1997
  • Pervaporation pilot tests for obtaining the anhydrous ethanol, which is an automobile fuel additive for reducing air pollution, were carried out in the production field of fermented ethanol by using a PVA composite membrane. In the pervaporation dehydration of the ethanol/water azeotropic mixture, the membrane performance is concluded to be enhanced with the heating temperature of feed. In the determination of the permeate condensation temperature from the viewpoint of energy cost, an Optimal temperature was found to be near $0{\circ}C$. The results on the dehydration of fermented ethanol were similar to those of synthetic ethanol, which indicates that the pervaporation performance is not influenced by impurities contained in the ethanol to be dehydrated. From a comparison of calculated energy needed in the system and measured value in the pilot test, it is confirmed that the latent heat for vaporization of permeant on the permeate side of membrane is supplied from the feed.

  • PDF

Modelling of Drying Shrinkage for Different Environmental Conditions (환경인자를 고려한 건조수축의 예측모델 개발)

  • 한만엽
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.1
    • /
    • pp.111-120
    • /
    • 1996
  • Drying shrinkage is a very important properties of concrete, which is affected by environmental conditions. The environmental conditions are temperature, relative humidity, and wind speed, which is quite variable and its effct on drying shrinkage is quite complex, too. In this study, environmental effects on drying shrinkage wrer integrated into one variable-evaporation rate. In several different environmental conditions, evaporation rate was measured with Evaporometer and compared with PCA chart, and also compared with measured drying shirnkage to verify the possibility of being a single parameter. The results are summarized in a prediction chart and prediction equation for drying shrinkage.

Performance Characteristics of Cascade Refrigeration System Using R744 and R410A (R744-R410A용 이원 냉동시스템 성능 특성)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1548-1554
    • /
    • 2013
  • This paper presents the analysis on performance characteristics of R744-R410A cascade refrigeration system to offer the basic design data for the operating parameters of this system. The performance of cascade refrigeration system is analyzed by using EES program. The operating parameters include compressor efficiency, and condensing and evaporating temperature in R410A high- and R744 low-temperature cycle, respectively. The COP of this system increases with the decrease of condensing temperature, and increases with the increasing evaporating temperature. And the COP of this system increases with the compression efficiency. Therefore, it can be seen that the compression efficiency, and evaporating and condensing temperature of R744-R410A cascade refrigeration system have an effect on the COP of this system. Also, it can be known that the cascade evaporation temperature with the highest efficiency in each parameter is present. Thus, it is an important to design R744-R410A cascade refrigeration system by considering these parameters.

Calibration of the Hargreaves Equation for the Reference Evapotranspiration Estimation on a Nation-Wide Scale (우리나라 기준 증발산량 산정을 위한 Hargreaves 계수 산정)

  • Lee, Khil-Ha;Park, Jae-Hyeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.675-681
    • /
    • 2008
  • In this study, the daily-based reference evapotranspiration was evaluated with Hargreaves equation at the 23 meteorological stations for the time period of 1997-2006. The Hargreaves coefficient was self-calibrated to give the best fit with Penman-Monteith evapotranspiration, being regarded as a reference. On the basis of the estimated parameter set, a generalized regression was conducted to estimate the Hargreaves evapotranspiration by just using temperature data. This study will contribute to water resources planning, irrigation schedule, and environmental management.

Exergy Analysis of R744 OTEC Power Cycle with Operation Parameters (작동변수에 따른 R744용 해양온도차 발전 사이클의 엑서지 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1036-1042
    • /
    • 2012
  • This paper describes an analysis on exergy efficiency of R744 OTEC power system to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling and superheating degree, evaporation and condensation temperature, and turbine and pump efficiency, respectively. The main results are summarized as follows : As the evaporation temperature, superheating degree, and turbine and pump efficiency of R744 OTEC power system increases, the exergy efficiency of this system increases, respectively. But condensation temperature and subcooling degree of R744 OTEC power system increases, the exergy efficiency of this system decreases, respectively. The effect of evaporation temperature and pump efficiency on R744 OTEC power system is the largest and the lowest among operation parameters, respectively. Therefore, the refrigerant temperature in the evaporator must be closely to the surface seawater temperature to enhance the exergy efficiency of R744 OTEC power system.

Spatial Estimation of Satellite-based Landcover Classification in Han River Watershed (인공위성 데이터를 기반으로 한 한강 유역 토지 피복의 공간 분포 산정)

  • Choi, Minha;Han, Seungjae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.170-170
    • /
    • 2011
  • 토지피복은 지표면의 물리적 상태 및 사용 용도에 따른 특성을 나타내는 기본적인 정보로 농업, 환경, 재해, 수자원 등 다양한 분야에서 이용되고 있다. 식생활동으로 인해 생기는 증산과 토양에서 일어나는 증발을 증발산이라 통칭하며, 이의 정확한 산정은 수리, 수문학적 유역 분석에 중요하다. 정확한 증발산의 산정을 위해서는 기압, 온도 등 기상 인자의 역할이 중요하지만 토지피복 특성 역시 증발산에 큰 영향을 주므로 중요한 요소 중 하나이다. 이는 인간의 활동에 의해 점차적으로 빠르게 변화하는 추세이므로 인공위성 영상을 이용하여 효율적인 정보의 취합 및 관리가 필수적이다. 따라서 본 연구에서는 Landsat 5 TM(Thematic Mapper) 영상을 기반으로 무감독 분류법을 이용하여 ISODATA Training과 Masking기법을 사용하여 한강 유역의 토지피복도를 산정하였다. 본 연구에서는 연구 대상 지역의 영상을 사용하였고, 토지의 분류는 수역, 시가, 나지, 습지, 초지, 산림, 농지의 7가지로 분류하였다. 그 결과 우리나라의 대다수를 이루는 수역, 시가, 산림, 농지에 대한 높은 정확도를 갖는 토지피복도를 얻을 수 있었으며, 이는 군사경계 외부의 지역도 포함된 결과이다. 단, 나지와 습지, 초지 부분의 정확도는 비교적 떨어지나, 우리나라의 토지특성상 많은 비율을 차지하고 있지 않으므로 신뢰할 만한 결과라 할 수 있겠다. 이 결과와 외부 자료를 이용하여 보다 향상된 토지피복도를 만들 수 있을 것이다. 이를 토대로 군사지역 등 접근이 어려운 지역의 토지피복 현황을 파악하여 정확한 증발산 산정에 도움이 되고자 한다.

  • PDF

CIGS 박막 태양전지를 위한 $(In,Ga)_2Se_3$ 전구체 제작 및 분석

  • Jo, Dae-Hyeong;Jeong, Yong-Deok;Park, Rae-Man;Han, Won-Seok;Lee, Gyu-Seok;O, Su-Yeong;Kim, Je-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.285-285
    • /
    • 2010
  • $Cu(In,Ga)Se_2$ (CIGS) 박막 태양전지 제조에는 동시증발법 (co-evaporation)으로 Cu, In, Ga, Se 각 원소의 증발을 세 단계로 제어하여 CIGS 박막을 증착하는 3-stage 방법이 널리 이용된다[1]. 3-stage 중 1st-stage에서는 In, Ga, Se 원소 만을 증발시켜 $(In,Ga)_2Se_3$ 전구체 (precursor) 박막을 성장시킨다. 고효율의 CIGS 태양전지를 위해서는 $(In,Ga)_2Se_3$ 전구체 증착의 공정 변수와 이에 따른 박막 특성의 이해가 중요하다. 본 연구에서는 Mo 박막이 증착된 소다석회유리 (soda lime glass) 기판에 동시증발장비를 이용하여 280 380 의 기판 온도에서 In, Ga, Se 물질을 증발시켜 $(In,Ga)_2Se_3$/Mo/glass 시료를 제작하였으며 XRD, SEM, EDS 등의 방법을 이용하여 특성을 분석하였다. XRD 분석 결과 기판 온도 $280{\sim}330^{\circ}C$에서는 $(In,Ga)_2Se_3$ 박막의 (006), (300) 피크가 관찰되었으며, 기판 온도가 증가할수록 (006) 피크 세기는 감소하였고 (300) 피크 세기는 증가하였다. $380^{\circ}C$에서는 (110)을 포함한 다수의 피크가 관찰되었다. 그레인 (grain) 크기는 기판 온도가 증가할수록 커지며 Ga/(In+Ga) 조성비는 기판 온도에 따라 일정함을 각각 SEM과 EDS 측정을 통해 알 수 있었다. $(In,Ga)_2Se_3$ 전구체의 (300) 배향은 CIGS 박막의 (220/204) 배향을 촉진하고[2], 이것은 높은 광전변환효율에 기여하는 것으로 알려져 있다. 때문에 $(In,Ga)_2Se_3$의 (300) 피크의 세기가 가장 큰 조건인 $330^{\circ}C$를 1st-stage 증착 온도로 하여 3-stage CIGS 태양전지 공정을 수행하였으며, $MgF_2$/Al/Ni/ITO/i-ZnO/CdS/CIGS/Mo/glass 구조의 셀에서 광전변환효율 16.96%를 얻었다.

  • PDF

증발기의 최적운전

  • ;Chung K. S.
    • Nuclear industry
    • /
    • v.7 no.8 s.54
    • /
    • pp.56-61
    • /
    • 1987
  • 원자력발전소에서 생성되는 폐기물들의 양을 줄이는 것은 주요한 관심사이다. 방사성폐기물의 감용은 여러 방법으로 성취될 수 있는데, 본고에서는 액체폐기물 처리계통의 증발기를 효율적으로 운전하여 폐기물의 양을 감소시키는데 초점을 맞추었다. 이를 위해, 온도와 pH를 변화시키면서 농도가 다른 붕산수들의 침전상태가 조사되었는데, 배관의 보온을 고려하지 않았을 때는 붕산농도 $17wt.\%$까지, 고려했을 때는 $25wt.\%$까지 농축할 수 있음이 밝혀졌다. 또한, 붕산농도의 증가에 따른 시멘트고화체의 압축강도변화를 조사하였고 증발기 농축운전으로 얻어질 경제적 이들을 평가하였다.

  • PDF