Separate type heat pipe performance comparison by the heat exchanger shapes (열교환기 형상에 따른 분리형 히트파이프 성능 비교)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.723-729
    • /
    • 2016
  • This study compared fin-tube and parallel-flow heat pipes for their sensible heat exchange rate, heat recovery amount, and air-side pressure drop. Tests were done with different refrigerant charging rates of 40-60% vol. and air flow rates of 300-1,400. The sensible heat exchange rate was highest for both types of heat pipes at a working fluid charge of 40% vol. and low flow rate. For the parallel-flow heat pipe, the 60% vol. charge is too high and results in a low sensible heat exchange rate. The reason is that the thicker liquid film of the tube wall deteriorates the heat transfer effect. Hence, the optimal charging rate is 40 to 50% vol. The evaporator heat pipe has a larger air-side pressure drop than the condenser section heat pipe. The reason is considered to be condensation water arising from the evaporator surface. Compared to the fin-tube heat pipe, the parallel-flow heat pipe showed better performance with a working fluid charging rate of 48%, volume of 41%, and an air-side pressure drop about 37%.

Analysis of the Hydrological Components of the Chatancheon Catchment 2019 Year (2019년 차탄천 유역의 수문성분 분석)

  • Kim, Dong Phil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.273-273
    • /
    • 2020
  • 환경부 홍수통제소의 경우는 전국단위의 강수량(지상, 레이더), 하천수위, 유사량 관측과 국부적으로 증발산량과 토양수분 관측이 이루어지고 있는 상황이며, 기상청 및 다른 공공기관도 각 목적에 맞게 수문기상관측이 이루어지나 유역(또는 지역) 단위의 물순환 과정(강우량, 유출량, 증발산량, 지하수함양량, 토양수분량 등 포함)을 규명하는 조사·연구는 매우 미비한 실정이다. 개별적인 물순환 성분별 수문조사에서 벗어난 전체적인 관점을 고려한 유역단위의 물순환 과정을 규명하는 것은 매우 중요하다. 즉 물순환 성분별 명확한 수문량 산정 결과는 수자원 개발과 물환경 보전에 중요한 정보를 제공할 수 있다. 따라서 물순환 성분별 명확한 분석을 위해서는 중·소규모 유역 단위를 대상으로 지속적이고 신뢰성 있는 자료의 획득과 축적이 중요하므로 중·소규모 유역단위의 대표성 있는 시험유역의 운영은 매우 의미가 있다고 볼 수 있다. 본 논문에서는 한국건설기술연구원에서 운영하는 차탄천 유역(유역면적 190.64㎢, 유로경사 0.96%, 경기도 연천군 소재)의 신뢰성 높은 2019년 관측자료를 이용하여 물순환 성분인 강우량, 하천유출량, 증발산량의 자료를 산정하였으며, 물순환 성분별 균형을 이루는 자료를 생성하였다. 기본 관측자료인 강우량은 각 지점강우량의 관측자료의 비교·검토 등 품질관리를 통해 자료를 확정하고 유역평균강우량을 산정하였다. 하천수위는 기준수위표와의 검토, 상·하류 검토를 통해 자료를 확정하였으며, 하천유출량은 유량측정성과와 단면검토를 통해 수위-유량관계곡선식을 개발하고, 확정된 수위자료를 적용하여 산정하였다. 그리고 증발산량은 유역내의 기상관측자료를 활용하여 잠재증발산량을 산정하였다. 각 물순환 성분별로 산정된 자료는 과거년 자료와 비교·평가를 통해 균형성을 판단하였다. 각 성분별 최대치와 최소범위, 평균값을 고려하고, 강우일수, 강우의 강우강도와 지속기간, 기상자료(기온, 일조시간, 습도, 풍속 등)를 충분히 고려하였다. 각 물순환 성분별로 생성된 2019년의 차탄천 유역의 총강우량은 975.9mm이며, 하천유출량은 507.9mm(총강우량 대비 52.0%), 실제증발산량은 366.4mm(37.5%), 지하수함양량은 101.6mm(10.4%)이다. 여기서, 실제증발산량은 유역내 1개 지점의 잠재증발산량을 산정하여 추정한 값이며, 지하수 함양량을 산정을 위한 지하수위 관측정이 부재한 상황이나 물순환의 폐합 조건을 고려하여 산정하였다. 이와 같이 산정된 물순환 성분별 자료는 유역의 물순환 과정 규명을 위한 기초자료로 매우 유용하게 활용될 수 있으며, 유역 물관리를 위한 의사결정 과정에 중요한 역할을 할 수 있을 것으로 기대된다.

  • PDF

자동차를 위한 진공 기술 - 누설 탐지(Leak Detection)를 중심으로 -

  • Ju, Jang-Heon
    • Vacuum Magazine
    • /
    • v.3 no.4
    • /
    • pp.41-46
    • /
    • 2016
  • 자동차 생산에 필요한 진공 기술들을 누설 탐지 관점에서 먼저 살펴 보고, 누설 탐지가 필요한 차량 부품들과 해당 부품들에 적용되는 누설량(leak rate)을 알아 보자. 후반부에는 차량 연료 증발로 인해 발생하는 연료 누설 탐지와 차량을 정지시키는데 필요한 제동력을 진공을 이용하여 얻을 수 있는 진공 부스터(vacuum booster)를 매우 간략하게 설명하도록 한다.

  • PDF

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

A fundamental Study on the Manufacturing and Operating Characteristics of a Small Scale CPL Heat Pipe (소형 CPL 히트파이프의 제작 및 작동 특성에 관한 기초연구)

  • 안영길;유성열;임광빈;김철주
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.17-22
    • /
    • 2003
  • The present study was conducted to obtain the fundamental knowledge on the manufacturing and operating characteristics of a small scale CPL (Capillary Pumped Loop) heat pipe. CPL heat pipes are able to transfer heat effectively at any orientation in a gravitational field over long distances. An experimental model with an evaporator of a circular plate shape was designed and manufactured and its operating performances were tested. A Bronze powder sintered metal plate of 3 mm thick and $\Psi$ 50 mm was used as wick and ethanol was used as working fluid. An experimental apparatus was set up to ascertain the operating conditions oi CPL at different heat load and an surrounding temperature at the condenser was maintained about 13$^{\circ}C$.

A Study on Operating Characteristics and Development of Woven-Wired Wick Heat Pipe (편조 윅 히트파이프의 개발과 작동특성에 관한 연구)

  • Moon, Seok-Hwan;Choi, Choon-Gi;Hwang, Gunn;Choy, Tae-Goo
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.54-59
    • /
    • 2000
  • 전자부품 및 시스템의 고속/고밀도화 추세에 따라 발열밀도가 계속증가하고 있다. 최근 팬티엄 II 급이상의 노트북 컴퓨터의 CPU에서는 칩당 발열량이 10W 이상으로 증가하고 있고 패키징 공간의 제한 때문에 소형히트파이프를 이용한 냉각이 많이 적용되고 있다. 본 연구에서는 모세압구동력이 크고 생산성등이 고려된 편조 형태의 새로운 윅을 개발하였으며 , 노트북 컴퓨터의 CPU 등 소형 전자부품냉ㄱ가에 적용가능한 직경 3, 4 mm 히트파이프를 설계 및 제작하였다. 직경 3, 4 mm Miniature Heat Pipe (이하 MHP) 의 작동특성은 일반적인 중형히트파이프와 다르므로 MHP 의 열전달 특성 및 작동성능에 미치는 각종 인자들의 영향을 파악하고자 성능시험을 수행하였다. 고려된 작동인자로는 작동유체 충전률, 전체 파이프길이 및 증발부, 응축부길이, 설치 경사각, 윅의 가닥수, 열부하 등이다. 작동인자의 영향과 관련된 연구결과는 향후 패키징을 위한 응용연구의 기초자료로 활용할 수 있을 것이다.

  • PDF

An Experimental Study on Heat Transfer Characteristics of the Heat Pipe with a Double Vapor Path (이중 증기통로를 가지는 히트파이프의 열전달특성에 관한 실험적 연구)

  • Jun, C.H.;Jang, Y.S.;Kim, O.G.;Noh, I.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.27-32
    • /
    • 2002
  • The Characteristics of heat transport in the heat pipe with a double vapor path and different kinds of the working fluid were investigated experimentally. The Experiment was carried out with acetone/ethanol. ethanol/ethanol. and in the aluminium container of the double vapor path. Performance measurements can be operated at the high level by 24000 w/m2 heat flux in the 1000mm evaporator. They are each estimated at the high temperature and experimentally reviewed the characteric of the heat rejection. The results shew that they are stably operated under each condition and the fluid was complemented each other at the fluid's experiment and brought about the extention of operating temperature. In this study, The reliable basic data obtained by the teste in the heat pipe with a double vapor path can be used for thermal design, manufacture, and production etc.

Evaporation Heat Transfer Characteristics of Propane and Iso-butane in Micro-fin Tubes (마이크로핀관에서 프로판과 이소부탄의 증발 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.35-40
    • /
    • 2007
  • In this paper, evaporation heat transfer characteristics of propane and iso-butane in micro-fin tubes were investigated experimentally. Test section has a micro-fin tube with outside diameter of 12.70 mm, and 75 fins with a fin heights of 0.25 mm. The experimental results summarize as the followings: The average evaporation heat transfer coefficients of He's refrigerants is higher than those of HCFC22, and appeared in the order of iso-butane, propane with respect to the approaching of the high mass flux. The evaporation heat transfer coefficient of micro fin tube is about $10{\sim}80%$ higher than those of smooth tube. This results from the study can be used in the case of designing heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF

향류식 역삼투 농축공정을 이용한 NaCl 용액의 농축연구

  • 조한욱
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04b
    • /
    • pp.3-10
    • /
    • 1997
  • 제염농축공정은 증류, 증발법을 일반적으로 사용하나, 에너지 절약차원에서 전기투석 (Electro dialysis)장치를 증발기 선단에 도입한 복합공정을 국내에서도 사용하고 있는 실정이다. 그러나, 전기투석장치는 전기적인 소모와 막의 재생, 교체처리비가 문제점이 되므로 역삼투 장치를 제염농축 공정 최선단에 도입한 복합공정을 이용할 경우 전기 투석 및 증발 복합공정에 비해 40%의 에너지 절감 효과를 기대할 수 있다. 이와 같은 장점에도 불구하고 역삼투 공정은 공급용액의 삼투압보다 큰 적용압력을 막표면에 가하여 물질분리를 수행하므로 농축공정에서 유발되는 배제액 농도의 상승은 삼투압의 증가를 일으켜 실적적용압력의 효과를 떨어뜨리게 되며 결과적으로 농축효과를 감소시키게 된다. 본 연구에서는 효과적인 염농축 공정을 위하여 막모듈 투과부에 고농도 삼투압 감소액(osmotic sink solution)을 향류식(막투과흐름을 맞받아치며 흐르는 방식)으로 유입시키는 향류식 역삼투 (counter-current reverse osmosis, CCRO) 나권형 모듈을 고안 제작하였으며, 제작된 모듈을 기존 역삼투 공정과 향류식 염삼투 공정에 적용하여 염농축도의 성능을 상호 비교하고 염농축에 관계되는 공급농도, 공급유량, 투과유량, 배제유량, 향류 유입유량, 압력구배, 삼투압차 및 농축단수 등의 인자들을 이용하여 두 공정에 대한 염농축 분리조작의 제반조건과 제작된 모듈 내의 농축관련 특성을 실험 및 수치적으로 비교, 고찰하였다.

  • PDF

Planting Guidelines for Home Energy Savings (주택 에너지 절약을 위한 식재계획 지침)

  • 조현길
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.4
    • /
    • pp.63-74
    • /
    • 1995
  • 본 연구의 목적은 주택의 냉방 및 난방에너지 절약을 위한 적절한 식재계획의 지침을 제시하기 위함이었다. 본 연구의 대상지는 미국 중동부 내륙의 한 도시인 쉬카고(Chicago)의 북서쪽에 위치한 주거지였다. 쉬카고 는 온대 기후대에 속하는 도시로서, 본 연구는 한국 중부지역의 주택들에 있어서 식재를 통해 냉방 및 난방에너지를 절약하고, 또한 그 에너지 절약 으로부터 대기오염물의 배출을 저감하는데 유용한 정보를 제공할 것이라고 사료된다. 본 연구는 주택의 에너지 절약에 기여하는 주택주변 현존 식생 의 차양(Shading), 증발산 및 방풍의 효과를 모델링하였다. 식재로부터 절 약된 에너지의 총비용은 식생피도가 58.9%인 주거블럭에서 1993년 한해동 안 한 가구당 46.3달러였다. 그 중, 증발산효과가 53.7%, 방풍효과가 26.1%, 차양효과가 20.2%를 각각 차지하였다. 한편, 피도가 36.3%인 주거블럭에서 의 연간 총 에너지 절약은 가구당 8.6달러였다. 식생피도가 높은 주거지에 서 식재에 의한 에너지 절약의 효과는 더욱 증대되었다. 그러나, 대부분의 현존 수목은 부적지에 위치되어 겨출철에 주택내로의 광선의 입자를 차단 함으로써 난방에너지의 요구를 증가시켰다(수목 한 개체당 최대 6달러). 차 양효과를 최대화하기 위해서는 주택건물의 남쪽가까이에서는 교목의 식재 를 가급적 회피하고, 수관이 가능한 한 넓은 교목을 주택건물의 서쪽과 동 쪽가까이에 식재하여야만 한다. 증발산과 방풍의 효과를 증진하기 위해 건 물의 북쪽, 북동쪽 및 북서쪽에서의 고밀도 식재가 요구된다.