• Title/Summary/Keyword: 증기 압축식 냉동

Search Result 22, Processing Time 0.019 seconds

Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System (R744용 초임계 냉동사이클의 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2009
  • In this paper, cycle performance analysis for cooling capacity, compression work and COP of R744($CO_2$) transcritical vapor compression refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : The cooling capacity of R744 increases with superheating degree, but decreases with the increasing evaporating temperature and outlet temperature of gas cooler. The compression work increases with superheating degree and cooling pressure of R744, but decreases with the increasing evaporating temperature. And, The COP increases with outlet temperature and evaporating temperature of R744 gas cooler, but decreases with the increasing superheating degree. Therefore, superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

건물공조용 CHP시스템의 흡착식 냉동기 적용

  • 박윤철
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.34 no.2
    • /
    • pp.28-32
    • /
    • 2005
  • 최근에 보급이 활성화되고 있는 CHP시스템을 건물공조용으로 이용할 경우에 필수적인 증기압축식 냉동기를 대체할 열구동 냉동기로써 흡착식 냉동기 기술을 언급하였다

  • PDF

이젝터 냉동 시스템

  • 이원희
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.34 no.2
    • /
    • pp.23-27
    • /
    • 2005
  • 기존 증기압축식 냉동시스템에 이젝터를 장착하여 시스템 효율을 향상시키는 여러 가지 방안과 상용화된 Denso 이젝터 시스템에 대해 소개하고자 한다.

  • PDF

An Experimental Study of the Performance Characteristics on Multiple-tube Heat Exchanger in the Vapor Compression Refrigeration System (증기압축식 냉동장치에서 다증관 열교환기의 성능특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • This paper is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this paper are basic data to design the optimum tripple-tube heat exchanger.

흡수식 열펌프 작동유체로서의 나노유체냉매 적용

  • Lee, Jin-Gi;Gang, Yong-Tae
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.37 no.7
    • /
    • pp.4-8
    • /
    • 2008
  • 현재 사용되어지는 냉매에 대한 규제와 에너지 수급불균형의 문제를 해결하기 위해 증기압축식 냉동기의 대체방안중 하나인 흡수식 시스템에 대해 알아보고 흡수식 시스템의 성능향상을 위해 차세대 냉매인 이성분 나노유체의 적용가능성을 제시하고자 한다.

  • PDF

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.

An Experimental Study on Performance of Vapor Compression Refrigeration Cycle with Al2O3 nano-particle (Al2O3 나노 입자를 적용한 증기 압축 냉동 사이클의 성능)

  • Kim, Jeongbae;Lee, Kyu-Sun;Lee, Geunan
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.124-129
    • /
    • 2015
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle using inverter scroll compressor with and without $Al_2O_3$ nano particle. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDY to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. The COP of refrigeration cycle with $Al_2O_3$ nano-particle was similar with that of the base cycle without nano-particle between 1000~3000 rpm of the compressor speed. But, This study showed that the COP of the cycle with $Al_2O_3$ over 3000 rpm of the compressor speed was higher than that of the base cycle due to the higher heat transfer rate increased in the evaporator from the higher oil flow rate inside the cycle as well known. Those results can be used the basic and fundamental data to design the air-conditioning cycle using inverter scroll compressor with $Al_2O_3$ nano particle.

에어컨용 냉매압축기

  • 이승갑;소순갑;최영민
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.11
    • /
    • pp.8-14
    • /
    • 2002
  • 가정용 룸에어컨이나 가정, 점포, 사무실에 사용하는 패키지에어컨은 쾌적한 주거 사무공간을 실현할 수 있기 때문에 최근 10년 동안에 광범위하게 보급되었고, 그 기술도 해마다 진보하고 있다. 그림 1에서 나타나듯이 2001년 가정용 룸에어컨의 국내생산 수량은 연간 600만대 수준이며, 패키지에어컨은 연간 약 80만대 수준이다. 2001년 기준으로 에어컨의 국내시장규모는 약 130만대로 세대 보급률이 약 40%에 도달하고 있다. 비록 패키지에어컨은 생산 수량면에서는 룸에어컨과 비교할 수 없지만, 한대의 냉방능력이 룸에어컨의 수배에서 수십배로 크기 때문에 전력에너지소비, 환경 등에 미치는 영향은 룸에어컨과 비견될 수 있다. 공조장치 보급에 따른 환경, 에너지 측면에서의 사회적 영향과 관심이 점차 커지고 있고, 이것을 개선하기 위한 기술개발이 활발하게 진행되고 있다. 에어컨을 포함한 공조장치의 다수는 효율이 좋은 증기 압축식 냉동사이클로써 구성되어 있으며, 증기 압축식 사이클에서 냉매가스를 압축하여 순환시키는 심장역할을 하고 있는 것이 압축기이다. 또한 압축기는 공조장치 전체의 전력소비의 80%에서 90%을 차지하고 있어 에너지절감 기술개발과 환경기술개발의 포인트가 되는 기구이다. 최근에 에어컨용 냉매압축기의 기술적인 개발동향을 정리하면 다음과 같은 경향으로 진행되고 있다. (1)오존층 파괴 지수가 제로인 친환경 HFC계와 자연냉매용 밀폐형 압축기기술 (2)로터리압축기의 성능향상 및 대용량화 기술 (3)압축기용 모터의 DC화통에 의한 모터 효율 향상 및 압축기 효율 향상 기술 (4)스크롤압축기의 압축비 변화의 대응, 고효율 유지, 대용량화 등 성능향상기술 (5)로터리, 스크롤, 왕복동 압축기를 이용한 용량가변기술 본 논고에서는 룸에어컨과 패키지에어컨에서 사용되고 있는 밀폐형 압축기에 대해서 그림 2에서 나타내고 있는 냉방능력 10tons(120,000Btu/h) 이하를 중심으로 상기의 최근 기술 동향을 간략하게 소개하고자 한다.

  • PDF

Development of Cascade Refrigeration System Using R744 and R404A - Analysis on Performance Characteristics - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(1) - 성능 특성에 관한 분석 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • In this paper, analysis on the performance characteristics of R744-R404A cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : It was observed that the highest COP of the system is achieved by higher superheating degree in R744 cycle than that in R404A cycle. The COP of the system increased by giving the subcooling degree in both cycles. The COP of the cascade system is the highest value when the system is operated at an optimum evaporation temperature.

Magnetic Refrigeration Apparatus at Room Temperature Using Concentric Halbach Cylinder Permanent Magnets (동심 원통형 Halbach 배열 영구자석을 이용한 상온 자기냉동장치)

  • Lee, Changho;Lee, Jong Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.47-51
    • /
    • 2017
  • Recently international cooperations are formed to deal with the environmental pollution of the atmosphere generated by the vapor compression refrigeration system. A refrigeration technique, which can replace existing CFC refrigerants that are the main cause of environmental contamination, has received greater attention. Magnetic refrigeration is a refrigeration technique using the magnetocaloric effect of the magnetic material, and is an eco-friendly refrigeration technology using the solid refrigerant instead of CFC refrigerants. Also it is regarded as an efficient refrigeration system to generate temperature difference between high and low sides using the temperature change of magnetic refrigerants according to the change of magnetic field, instead of using power-consuming and noisy compressor. In this paper, we introduce the magnetic refrigeration apparatus using concentric Halbach cylinder permanent magnets and the experimental results using the apparatus.