• Title/Summary/Keyword: 증기폭발

Search Result 137, Processing Time 0.045 seconds

A Study on the Evaluation of Classification Performance by Capacity of Explosive Components using Convolution Neural Network (CNN) (컨볼루션 신경망(CNN)을 이용한 폭발물 성분 용량별 분류 성능 평가에 관한 연구)

  • Lee, Chang-Hyeon;Cho, Sung-Yoon;Kwon, Ki-Won;Im, Tae-Ho
    • Journal of Internet Computing and Services
    • /
    • v.23 no.4
    • /
    • pp.11-19
    • /
    • 2022
  • This paper is a study to evaluate the performance when classifying explosive components by capacity using a convolutional neural network (CNN). Among the existing explosive classification methods, the IMS steam detector method determines the presence or absence of an explosive only when the explosive concentration exceeds the threshold set by the user. The IMS steam detector has a problem of determining that even if an explosive exists, the explosive does not exist in an amount that does not exceed the threshold. Therefore, it is necessary to detect the explosive component even when the concentration of the explosive component does not exceed the threshold. Accordingly, in this paper, after imaging explosive time series data with the Gramian Angular Field (GAF) algorithm, it is possible to determine whether there are explosive components and the amount of explosive components even when the concentration of explosive components does not exceed a threshold.

염화탄화수소의 화재 및 폭발 위험성 평가

  • 하동명;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.433-438
    • /
    • 2002
  • 화재 및 폭발 특성치로 인화점, 최소발화온도, 폭발한계, 최소발화에너지, 연소열 등을 들 수 있다 이 가운데 폭발한계(explosive limits)는 가연성물질(가스 및 증기)을 다루는 공정 설계 시 고려해야 할 중요한 변수로써, 발화원이 존재할 때 가연성가스와 공기가 혼합하여 일정 농도범위 내에서만 연소가 이루어지는 혼합범위를 말한다/sup 1)/. 특히 폭발범위는 온도, 압력, 불활성가스의 농도, 화임전과 방향, 용기의 크기, 무리리적 상태 등에 의해 변한다/sup 2)/.(중략)

  • PDF

A Review of the Methods for the Estimation of the Explosion Parameters for Gas Explosions (가스 폭발에 따른 폭발 인자 추정을 위한 방법 고찰)

  • Minju Kim;Jeewon Lee;Sangki Kwon
    • Explosives and Blasting
    • /
    • v.41 no.3
    • /
    • pp.73-92
    • /
    • 2023
  • With the increase of risk of gas explosion, various methods for indirectly estimating the explosion paramaters, which are required for the prediction of gas explosion scale and impact. In this study, the characteristics of the most frequently used methods such as TNT equivalent method, TNO multi-energy method, and BST method and the processes for determining the parameters of the methods were compared. In the case of TNT equivalent method, an adequate selection of the efficiency factor for various conditions such as the type of vapor cloud explosion and explosion material is needed. There is no objective guidelines for the selection of class number in TNO multi-energy method and it is not possible to estimate negative overpressure. It was found that there were some mistakes in the reported parameter values and suggested corrected values. BST method provides more detailed guidelines for the estimation of the explosion parameters including negative overpressure, but the graphs used in this methods are not clear. In order to overcome the problem, the graphs were redrawn. A more convenient estimation of explosion parameters with the numerical expression of the redrawn graphs will be available in the future.

Analysis on the Explosion Risk Characteristic of Hydrogen blended Natural Gas (HCNG 혼합연료의 폭발 위험 특성 분석)

  • Kang, Seung-Kyu;Kim, Young-Gu;Kwon, Jeong-Rak
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2014
  • This study investigated the explosion characteristics of HCNG fuel using a simulation tool. The damage caused by the storage container explosion and vapor cloud explosion in a gas station was predicted. In case of an vapor cloud explosion in the HCNG station, 50~200kPa explosion pressure was predicted inside the station. When the cylinder explosion was occurred, in case of hydrogen, the measured influential distance of overpressure was 59m and radiant heat was 75m. In case of CNG, influential distance of overpressure was 89m and radiant heat was 144m would be estimated. In case of 30% HCNG that was blended with hydrogen and CNG, influential distance of overpressure was 81m and radiant heat was 130m were measured. The damage distance that explosive overpressure and radiant heat influenced CNG was seen as the highest. HCNG that was placed between CNG and hydrogen tended to be seen as more similar with CNG.

Analysis of Fuel/Coolant Mixing in Steam Explosion (증기 폭발시 용융 핵연료/냉각수 혼합에 대한 해석)

  • Lee, Tae-Ho;Jo, Seong-Youn;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.215-221
    • /
    • 1993
  • A required initial condition for a steam explosion to occur following core meltdown accidents of a nuclear power plant is the formation of a coarse mixture of molten fuel and water. The extent of a premixing is the measure of efficiency of steam explosion that may follow. A simple one-dimensional, transient model and the flooding criteria have been applied to evaluate the fuel/coolant mixing limit. Also, both instant breakup and dynamic breakup models for the mixing process have been separately used here and compared each other. The results indicate that fuel temperature, ambient pressure, mixing diameter, water depth, and pouring diameter are the important parameters affecting the mixing behavior.

  • PDF

Impact Range Analysis of Small LPG Storage Tank Explosions at Highway Rest Areas (고속도로 휴게소 소형 LPG 저장탱크 폭발에 따른 영향범위 분석)

  • Seung duk Jeon;Soon Beom Lee;Jai Young Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.319-327
    • /
    • 2023
  • This study analyzes the risks of explosions of small LPG storage tanks installed at highway rest areas. For this purpose, the ranges of the effect of thermal radiation and overpressure caused by the BLEVE(Boiling Liquid Expansion Vapor Explosion)and VCE(Vapor Cloud Explosion) of a 2900-kg small LPG storage tank installed at highway rest areas were quantitatively evaluated by applying the Areal Location of Hazardous Atmospheres program. The ranges of influence of the derived explosion overpressure and thermal radiation were found to have a maximum radii of 336 m and 423 m, respectively. The study determined that those within 269 m could be severely injured by an explosion overpressure of 3.5 psi, and fatalities from thermal radiation of 10 kw/m2 could occur within 192 m of the exploded storage tank. The safety management plan for the LPG storage tank was discussed while considering the auxiliary facilities of highway rest areas and the extent of the damage impact. These research results will help improve safety accident prevention regulations considering the environment and facilities of the rest areas as well as the safety management of small LPG storage tanks installed at highway rest areas.

전기화재(IV) -가연물 취급장소에서 고려하여야 할 정전기 대책-

  • 원종수
    • Fire Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.47-57
    • /
    • 1988
  • 정전기에 의한 사고가 발생하려면, 정전기의 발생, 착화 능력을 가진 위험한 방전의 발생, 폭발성 가스, 증기가 공기와의 비율에서 폭발 한계 내에 존재할 것 등의 세가지 조건이 필요하다. 따라서 정전기에 의한 착화, 폭발 사고를 방지하기 위해서는 항상 이 세가지 관점에서 검토하여, 어떤 조건 하에서도 3개 조건 중 적어도 하나 이상을 제거하는 것이 필요하다. 이하, 정전기에 의한 재해 중에서 그 방전이 착화원이 되어서 발생하는 가연성 가스 등의 폭발, 화재에 의한 재해의 방지 대책에 한정해서 개설한다.

  • PDF