• 제목/요약/키워드: 증기고착

검색결과 8건 처리시간 0.024초

DP 가공조건이 면직물의 역학적 성질과 태에 미치는 영향 (Effect of DP Finishing Conditions on the Mechanical Properties and Hand of Cotton Fabrics)

  • 신윤숙
    • 한국의류학회지
    • /
    • 제24권3호
    • /
    • pp.440-447
    • /
    • 2000
  • The effects of DP finishing conditions including process technique and finishing agent on the mechanical properties and hand of cotton fabrics were investigated. 100% cotton fabrics were treated with NMA/DMDHEU and NMA/YF using wet-fixation and steam-fixation process. For comparison, conventional pad-dry-cure process was used with DMDHEU. After DP finishing, tensile and compressional resilience increased and bending hysteresis decreased, resulting in the improvement of dimensional stability of cotton fabric. WF and SF process rendered fabrics better shear properties, tensile energy, and compressional linearity and energy than PDC process. However, SF process produced fabrics with higher geometrical roughness than WF process. After DP finishing, primary hand values except Koshi increased, resulting in the increase of total hand value of cotton fabric.

  • PDF

강릉 신복사지 석조보살좌상 보물 제84호 수지상 오염물 제거 방안 연구 (Removing Resin Contaminants from the Seated Stone Buddha (Korean Treasure No.84) of Sinboksa Temple Site in Gangneung)

  • 이병훈;고형순
    • 박물관보존과학
    • /
    • 제15권
    • /
    • pp.56-65
    • /
    • 2014
  • 강릉에 위치한 신복사지 석조보살좌상 보물 제84호 얼굴부에 광택이 있는 수지상 오염물이 고착되어 있었다. 오염의 범위는 백호부터 턱 밑까지이며 광택이 발생하여 미관을 해치고 있었다. 오염물 중 일부를 수거하여 FT-IR 분석을 실시한 결과 시아노아크릴계 순간접착제인 것을 확인하였다. 분석된 접착제는 면봉 등에 아세톤을 묻혀 녹이면서 제거하는 방법이 일반적이다. 그러나 석조보살좌상이 야외에 오랜 시간 노출되어 있어 표면 풍화가 많이 진행된 상태이므로 이를 고려하여 물리적 손상을 최소화하는 방법으로 제거하였다. 기존에 처리된 삼전도비의 페인트 낙서 제거에 적용된 습포법과 도토기의 수지제거에 이용된 증기법을 검토하여 물리적 손상 없이 제거할 수 있는 방법을 찾아보았다. 습포법과 증기법을 같이 적용하면 면봉을 이용한 물리적 작업없이 24시간 이내에 수지가 제거되는 것을 확인하였고 이를 토대로 현장에 적용하였다.

저온 용융 합금물을 이용한 울진 1,2호기 원전 캐비티에 대한 노심용융물 고압분출 실험 연구

  • 박래준;김상백;김희동;김찬수;이규정
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.783-788
    • /
    • 1998
  • 국내 프랑스 가압경수형 원전인 울진 1,2호기 캐비티의 격납건물 직접가열에 대한 특성을 분석하기 위하여 노심용융물 고압분출 실험을 수행하였다. 본 연구에서는 환형통로 면적과 파손 직경에 따라 원자로용기 압력을 변화시키면서 용융물을 저온 용융 합금물인 Wood's Metal, 증기를 질소기체로 각각 모의하여 실험을 수행하였으며, 실험 결과는 물을 용융물 상사물로 사용한 전년 실험 결과(1)와 비교.분석하였다. 실험결과, 밀도가 물보다 큰 저온 용융 합금물을 사용한 경우는 물을 사용한 실험결과보다 밀도와 용융물의 벽면 고화고착 때문에 격납건물로 방출되는 용융물 양이 적게 나타났다. 물을 상사물로 사용한 경우와 같이 노심 용융물 고압분출에는 원자로 용기 파손직경이 많은 영향을 미치고 환형통로 면적은 큰 영향을 미치지 않는 것으로 나타났다. 노심용융물 고압분출 실험에 중요한 영향을 미치는 실험 상사물의 밀도와 용융물의 벽면 고화부착에 대해서는 종합적으로 분석하는 추가 연구가 필요하다.

  • PDF

강제순환상실시 CANDU-6 주열수송계통의 압력천이상태 해석

  • 김영보;한상구;김선철;정종식;주경인
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.160-165
    • /
    • 1996
  • 중수로형 원전에서 일차측 냉각수를 순환시키는 주연수송펌프가 정상운전중 갑자기 정지하는 사고를 강제순환 상실사고라 한다. 강제순환 상실사고는 주열수송계통을 과도압력상태로 만들며, 일반적으로 펌프에 공급되는 IV등급전원 상실사고와 기계적 손상에 의한 주열수송펌프 고착사고로 분류할 수 있다. 본 논문에서는 강제순환 상실사고에 대하여 중수로계통설계의 열수력 해석코드인 SOPHT를 이용하여 주열수송계통의 과도압력상태를 해석하였다. 카나다 원자력 규제위원회(AECB)의 과압 방지조건인 R-77 요구조건에 적절한 유효트립변수를 결정하기 위한 해석이 수행되었으며, 증기발생기 오염상태와 액체방출밸브 작동여부가 고도압력상태에 미치는 영향을 고찰하여 보수적 조건을 제시하였다. 또한 위와같이 결정된 보수적 조건을 근거로 ASME 코드에 명시된 과압 한계치에 대한 만족여부와 과도압력상태에 따른 주열수송계통의 열수력학적 거동을 고찰하여 보았다. 해석결과, 강제순환상실사고시 주열수송계통은 R-77 요구조건에 적합한 원자로트립변수에 따라 안정화되었으며, 계통의 최대압력은 ASME 코드가 규정한 한계치내에 있음을 알 수 있었다.

  • PDF

가열된 표면에 고착된 한 쌍의 액적 증발 특성 (Evaporation Characteristics of Paired Sessile Droplets on a Heated Substrate)

  • 이형주;황원영;김정호;최창경;이성혁
    • 한국분무공학회지
    • /
    • 제28권3호
    • /
    • pp.113-118
    • /
    • 2023
  • This study investigates the evaporation characteristics of paired sessile droplets on a heated substrate. In particular, the evaporation time and contact line behaviors were analyzed based on the droplet-to-droplet distance and substrate temperature. The contact line behavior and volume variations were visualized using the shadowgraph method. It was observed that the contact diameter and contact angle exhibited similar behavior for both single and paired droplets regardless of the droplet-to-droplet distance and substrate temperature. The paired droplets demonstrated a longer evaporation time than the single droplet due to the vapor accumulation between the droplets. Furthermore, the scaled lifetime, defined as the ratio of evaporation time between paired and single droplets, increased as the droplet-to-droplet distance decreased and decreased as the substrate temperature increased, attributed natural convection.

증거기반 창업교육: 대학 교재 분석

  • 한지은;김나영;배태준
    • 한국벤처창업학회:학술대회논문집
    • /
    • 한국벤처창업학회 2021년도 추계학술대회
    • /
    • pp.57-61
    • /
    • 2021
  • '증거기반 교육'은 개인적 경험이나 성공 사례, 그리고 전통적인 속설보다는 과학적 연구결과와 근거가 중심이 되는 교육이다. 증거기반 창업 교육은 기존 속설과 믿음, 단편적 성공 사례로 인해 고착된 인지 편향을 완화시켜 중립적인 시각을 견지할 수 있으며, 직관과 경험을 넘어 데이터와 연구 결과에 의해 의사결정을 하는 분석적 자질을 연마하는데 기여한다. 본 논문은 현재 국내의 증기기반 창업교육의 현주소를 명확히 파악하기 위하여 1999년부터 2021년 출판된 49권의 창업교육 대학 교재를 분석하였다. 구체적으로 모든 도서의 내용을 1)창업기초, 2)비즈니스모델, 3)마케팅계획, 4)재무계획, 5)운영계획, 6)창업유형, 7)절차 및 제도의 각 7가지 기준으로 구분하고, 각각 사례, 단순통계, 변인 통계, 선행 연구의 비중을 분석하였다. 분석결과 증거의 핵심인 선행연구의 비중은 전체 교재의 총 분량 중 11.25%를 차지하는 것으로 나타났다. 이는 Charlier(2011)의 MBA 교과목 대상으로 조사한 결과와 유사한 값이다.

  • PDF

재순환식 증기발생기 U-튜브군에 대한 유체탄성 불안정 해석 (Fluidelastic Instability Analysis of the U-Tube Bundle of a Recirculating Type Steam Generator)

  • 조종철;이상균;김웅식;신원기;은영수
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.200-214
    • /
    • 1993
  • 본 연구에서는 Westinghouse Model 51 증기발생기의 U-bend 영역에서 2차측 유체의 횡단유동으로 유발될 수 있는 튜브군의 유체탄성불안정을 예측하기 위한 해석 을 수행하고 그 대표적인 결과들을 제시하였다. 그리고 U-bend 영역에서 AVB에 의한 튜브의 지지상태와 형태 및 최상부 TSP에서 Denting 또는 이물질 고착으로 인하여 변 경된 튜브의 고정지지조건 등이 튜브의 유체탄성불안정 응답에 미치는 영향을 조사하 였다. 유체탄성불안정 해석과정에서 필수적으로 선행되어야 하는 2차측 3차원 2상 유동장 계산은 증기발생기 열수력 해석용인 ATHOS3 코드로써 수행되었으며, U-튜브의 고유진동수와 모우드 형상은 공학해석용 유한요소 프로그램인 ANSYS코드로써 계산되었 다.

Non-LOCA 인허가 해석용 TASS 코드의 개발 (Development of TASS Code for Non-LOCA Safety Analysis Licensing Application)

  • Yoon, Han-Young;Auh, Geun-Sun;Kim, Hee-Cheol;Kim, Joon-Sung;Park, Jae-Don
    • Nuclear Engineering and Technology
    • /
    • 제27권1호
    • /
    • pp.53-66
    • /
    • 1995
  • 현재 사용중인 Non-LOCA 해석용 인허가 코드들은 특정한 형태의 가압경수로에 맞게 짜여진 것들이어서 모든 형태의 가압 경수로에 적용할 수 있는 범용 코드의 개발이 필요한 실정이다. 이를 위하여 한국원자력연구소에서는 웨스팅하우스 및 CE형 발전소에 공히 적용할 수 있는 과도현상 해석 코드인 TASS 로드를 개발하고있다. 이 TASS 코드는 실시 간 보다 빠르게 핵증기계통에 대한 모의 계산을 수행하며 대화식의 입출력을 통하여 사용자가 원하는 과도현상을 정확히 모사할 수 있다. 본 논문에서는 웨스팅하우스형 발전소에 대하여 TASS 코드를 적용하여 Non-LOCA 인허가 해석을 하기 위한 검증을 위해, 교류 전원 상실사고와 부하상실사고에 대하여 발전소 실측자료와의 비교계산을 수행하였고 주급수관 파단사고, 펌프축 고착사고, 증기발생기 세관 파열사고 및 주증기관 파단사고들에 대하여 대형코드인 RELAP5 /MOD3 코드와의 비교계산을 수행하였다.

  • PDF