• Title/Summary/Keyword: 중합방법

Search Result 759, Processing Time 0.028 seconds

A Study on the Preparation of Wood-Plastic Combinations(III) Preparation of Wood-Plastic Combinations by Thermal Curing Method

  • Kim, Jaerok;Lee, Kyung-Hee;Pyun, Hyung-Chick
    • Nuclear Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.301-305
    • /
    • 1972
  • The polymerization rates of monomer or monomer mixture impregnated with catalyst into domestic soft woods such as pinus densiflora, pinus rigida and poplus deltoides e. t. c. were measured. The results were compared with those obtained by radiation curing method and the following conclusions were derived ; (1) Pinus densiflora and pinus rigida are superior to the poplus deltoides, and methyl methacrylate(M. M. A. ) is more effective than other monomers as far as the polymerization rates are only taken into account. (2) The polymerization rate of vinyl acetate is generally slow. And the polymerization rate of the monomer is the slowest in case of being impregnated into poplus deltoides. However, the polymerization rate of the comonomer composed of vinylacetate and M. M. A. is the fastest among the other monomers or monomer mixtures in woods regardless of the curing method. (3) The general trend of polymerization of monomer in wood is similar to that of monomers themselves in both curing methods if the woods contain not much resin.

  • PDF

Iterative Least-Squares Method for Velocity Stack Inversion - Part A: IRLS method (속도중합역산을 위한 반복적 최소자승법 - Part A: IRLS 방법)

  • Ji Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.163-169
    • /
    • 2005
  • Recently, the velocity stack domain is having an attention as a very useful domain for various processing in seismic data processing. In order to be used in many applications, the velocity stack should be obtained through an inversion method and the used inversion should have properties like the robustness to noise and the parsimony of velocity stack result. Iteratively Reweighted Least-Squares (IRLS) method is the one of the inversion methods that have such properties. This paper describes the theoretical background, implementation of the method, and examines the characteristics and limits of the IRLS method.

Microleakage of class II posterior composite resin filling using various light curing methods (구치부 광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구)

  • Jong-Uk Par;Byeong-Hoon Cho;Ho-Hyun Son;Chung-Moon Um;Hyuk-Choon Kwon
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.326-331
    • /
    • 2001
  • 목적 - 최근 복합레진의 미세변연누출을 줄이기 위한 새로운 광중합 조사방법이 연구되고 있다. 또한 구치용 복합레진이 개발되면서 그 제조회사에서는 5mm 깊이까지 광중합이 가능하다고 소개하고 있다. 본 연구에서는 논리적 가설에 근거한 몇가지 광중합 조사방법이 구치부 class II 와동의 복합레진 충전시 미세변연누출에 어떠한 영향을 미치는지를 관찰하였다. 재료 및 방법 - 100개의 우식증이 없는 사람의 상하악 대구치를 사용했다. 각 치아에 교합-치은방향으로 4mm, 협설 4mm, 깊이 2mm의 class II 와동을 형성하여 인접치와 함께 베이스플레이트 왁스에 매몰하고 구치용 복합레진인 Surefil을 제조 회사의 지시대로 충전하였다. 이때 5가지의 광조사방법을 이용하여 5개의 군으로 나누어 중합하였다(Table 1). 수복된 치아들을 5$^{\circ}C$와 55$^{\circ}C$의 수조에서 번갈아 1분씩 총 500회의 온도변화를 주어 thermocycling을 실시한 후 근첨을 폐쇄하고 수복와동의 치은경계를 제외한 전 표면에 nail varnish를 2회 도포하였다. 2%의 methylene blue용액에 24시간 침적시키고 흐르는 물에 세척한 후 시편을 투명한 에폭시 레진에 매몰하였다. 매몰된 시편을 치아 장축에 평행하게 절단 연마하였다. 입체 현미경으로 미세변연누출을 관찰하고 Kruskal-Wallis One Way ANOVA 와 Dunn's Method로 통계처리 하였다. 결과 - 1. 미세누출은 1군, 4군과 5군, 2군 3군 순으로 증가였다. 이때 1군, 4군과 5군은 통계적 유의성이 없었다(P>0.05). 2. 2군의 경우 1군, 4군, 5군에 비교하여 유의성 있게 미세누출이 많았으며(P<0.05) 3군에 비하여 유의성 있게 적게 나타났다(P<0.05). 3. 3군의 경우 다른 방법들에 비교하여 통계적으로 유의성 있게 미세누출이 많았다(P<0.05).

  • PDF

An Analysis of the Landuse Classification Accuracy Using IHS Merged Images from IRS-1C PAN Data and Landsat TM Data (IRS-1C PAN 데이터와 Landsat TM 데이터의 IHS중합화상을 이용한 토지이용분류 정확도 분석)

  • 안기원;이효성;서두천;신석효
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.2
    • /
    • pp.187-194
    • /
    • 1998
  • In this study, effective multispectral Landsat TM band combinations for a merging with the high resolution IRS-1C PAN data using the IHS method to improve landuse accuracy is discussed. From the pre-classified image using the merged images with TM all six band images(with the exception of band 6 image) and PAN image, a sample data which has ten classes was generated. An evaluation of the overall classification accuracy for the representative seven merged images which were merged using each TM three-band images and IRS-1C PAN image by IHS method for the sample area. The increase in classification accuracy is most significant with the inclusion of two of TM4, TM5 and TM7 infrared band images. Especially, the largest increase(11.8 percent) in landuse classification accuracy were investigated when Landsat TM247 bands were merged with IRS-1C PAN data. The classification accuracy when TM three band image and PAN image were used without merging is higher than result of the case of using the merged images.

  • PDF

A Study on the Variance of Properties of Thin Film Composite Membrane according to change of International Polymerization Condition (계면중합조건에 따른 복합막의 물성 변화에 관한 연구)

  • 이동진;최영국;이수복;민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.17-20
    • /
    • 1998
  • 1. 서론 : 계면중합은 제조에 따른 박막의 성능 조절이 가능한 이유로 해서 역삼투용 복합막의 주요 제조 방법으로 제시되어 왔다. 계면중합을 응용하여 제조된 복합막의 성능은 반응 단량체의 종류, 용재의 종류, 단량체의 농도, 반응시간, 열처리 유무 및 온도와 시간 등에 의해 변한다. 한편 위의 변수에 절대적인 영향을 받고 아울러 단량체간의 몰 비가 성립하지 않음으로 해서 최적의 막 성능으로 제시되는 조건을 만족하기 위하여 주로 시행착오에 의한 방법을 동원하여 여러 변수에 다른 제조 막의 성능 고찰을 실시하여 왔다. (생략)

  • PDF

EFFECT OF CURING CONDITIONS ON THE MONOMER ELUTION OF ORTHODONTIC ACRYLIC RESIN (교정용 아크릴릭 레진의 중합조건에 따른 모노머 용리)

  • Noh, Hong-Seok;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.477-486
    • /
    • 2008
  • Acrylic resin is widely used in dental practice. However, the residual monomer in acrylic resin could act as a negative biocompatability on human body. The aim of this study was to evaluate the amount of the monomer elution from polymerized orthodontic acrylic resin. Orthodontic acrylic resin was used in the study. The curing condition of the resin was controlled by temperature, pressure, aquatic and atmospheric environment. The duration and amount of monomer elution and timedependent plot was recorded by high performance liquid chromatography. The result showed that the only monomer eluted from the resin was methyl methacrylic acid. And the amount of the monomer elution has diminished considerably by time progress especially within 24 hours. Furthermore, elution of the residual monomer was significantly lower in group of pressure, moisture and elevated temperature than control (p<.05). According to this study, it was thought that the elution of residual monomer might be influenced by curing environment.

  • PDF

THE COMPARATIVE STUDY OF THE MICROHARDNESS AND MICROLEAKAGE IN POLYMERIZATION OF COMPOSITE RESIN CURED WITH VISIBLE LIGHT AND PLASMA ARC CURING UNITS (가시광선과 플라스마 광선에 의한 복합레진 중합시 미세누출과 미세경도에 관한 연구)

  • Kim, Sang-Bae;Lee, Kwang-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.180-188
    • /
    • 2002
  • Newly developed curing units(plasma arc curing units) operate at relatively high intensity and are claimed to result in optimum properties of composite resin in a short curing time. The purpose of this study was to evaluate the microhardness and microleakage at the resin-tooth interface of two types of composite resins polymerized with visible light and plasma arc curing units. The results from the present study can be summarized as follows 1. Microhardness in each depth was shown to be higher in group AHL than AP3 & AP6. Group ZHL was lower than AP6 at surface(p<0.05) and had no statistically significant difference at 1mm and 2mm(p>0.05). In other depths, group ZHL was higher than ZP3 and ZP6(p<0.05). 2. The incremental reduction in microhardness with depth was shown to be in all group except in surface-1mm of group AHL and $1{\sim}2mm$ of group ZHL(p<0.05). 3. Degree of microleakage in all oops were shown to be higher in gingival margin than occlusal margin but no statistically significant difference(p>0.05). 4. Differences between curing methods in microleakage were shown to be no statistically significant difference(p>0.05). 5. Differences between composite resins in microleakage were shown to be no statistically significant differ once(p>0.05).

  • PDF