• Title/Summary/Keyword: 중심 주파수

Search Result 1,210, Processing Time 0.03 seconds

A Study on Frequency Spectrum Scanning for Maritime Autonomous Surface Ship's M-S2X (Maritime-Ship to Everything) Communication (자율운항선박용 선박중심직접통신(M-S2X) 주파수 탐색에 관한 연구)

  • Bu-young Kim;Wonsik Kang;Woo-Seong Shim
    • Journal of Navigation and Port Research
    • /
    • v.47 no.6
    • /
    • pp.419-429
    • /
    • 2023
  • The pinnacle of rapidly changing and advancing maritime transportation technology is expected to be the Maritime Autonomous Surface Ship (MASS). The implementation of various services within the MASS is likely to be feasible through the ship-centric network known as the S2X communication system. However, existing communication systems face issues such as service traffic saturation and failure to meet demanded functionalities, necessitating the proactive introduction of additional communication technologies. In this study, the concept of S2X communication for the MASS was redefined, deriving required functionalities and ultimately selecting frequencies suitable for utilization. Candidate frequency groups suitable for the derived communication requirements were identified, and communication frequencies prioritized for the initial application were chosen through expert consensus. It is anticipated that through further research, including experimentation to validate these frequencies, they could be utilized in implementing services for autonomous ship navigation in the future.

Design and Evaluation of Ultrasonic dental scaler produced for Finite Element Analysis (유한요소 해석을 통한 치과용 초음파 Scaler의 설계 및 평가)

  • Kim, Chul-Min;Lee, Young-Jin;Jeong, Young-Hun;Paik, Jong-Hoo;Kang, Kook-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.20-20
    • /
    • 2009
  • 치아의 치석제거 및 치골절삭에 사용되는 초음파 스케일러는 일반적으로 마그넷형과 압전형으로 구분할 수 있으며, 최근에 들어 소형화, 저전력, 정밀성, 저비용 등의 장점으로 인해 압전형이 주로 사용되고 있다. 국내의 대부분의 치과에서 한 대 이상 운용되는 초음파 스케일러는 대부분 유럽 제품으로며, 국내에서는 이를 대체하기 위한 제품이 출시되고 있으나 아직까지 유럽 제품에 비해 출력강도, 정밀도 등에서 성능이 모자란 현실로 시장에서 외면 받고 있다. 본 연구에서는 앞서 언급한 압전 초음파 스케일러에 대한 체계적인 연구를 진행하여 외국에 비해 상대적으로 성능이 떨어지는 초음파 스케일러의 성능을 개선하고자 하였다. 이를 위하여 스케일러의 진동 발생부, 즉 압전 세라믹과 SUS 재질의 head, tail 부로 구성된 진동발생부의 최적구조톨 도출하기 위하여 유한요소 해석을 실시하였으며, 스케일러의 중심주파수 28kHz에서 최대 출력이 발생할 수 있는 구조를 도출하였다. 스케일러의 Head 와 Tail 부문의 두께와 직경, 길이 변화에 따른 중심주파수 및 출력 변위의 경향분석을 실시하였으며, 이상의 결과를 바탕으로 실제 스케일러를 제작하여 시뮬레이션의 유효성을 검증하였다. 이상의 과정으로 거쳐 개발된 압전 초음파 스케일러는 다양한 Tip 종류의 영향을 최소화할 수 있으며, 중심주파수는 28~30kHz 에서 뛰어난 성능을 나타내어 기종 유럽제품의 성능을 앞지르는 특성을 확보할 수 있었다.

  • PDF

Design and Fabrication of Voltage Control Oscillator at X-band using Dielectric Resonator (유전체 공진기를 이용한 X-band 전압제어 발진기 설계 및 제작)

  • Han, Sok-Kyun;Choi, Byung-Ha
    • Journal of Navigation and Port Research
    • /
    • v.27 no.5
    • /
    • pp.513-517
    • /
    • 2003
  • In this paper, a VCDRO(Voltage Control Dielectric Resonator Oscillator} applied to X-band as stable source is implementea and constructed with a MESFET for low noise, a dielectric resonator of high frequency selectivity and high Q varactor diode to obtain a good phase noise performance and stable sweep characteristics. The designed circuits is simulated through the harmonic balance simulation technique to provide the optimum performance. The measured results of a fabricated VCDRO show that output is 2.22dBm at 12.05GHz. harmonic suppression -30dBc. phase noise -130dBc at 100kHz offset. and sweep range of varactor diode $\pm$18.7MHz. respectively. This oscillator will be available to X-band application.

Implementation of Voltage Control Dielectric Resonator Oscillator for FMCW Radar (FMCW 레이더용 전압제어 유전체 발진기의 구현)

  • 안용복;박창현;김장구;조현식;강상록;한석균;최병하
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.398-402
    • /
    • 2003
  • In this paper, a VCDRO(Voltage Control Dielectric Resonator Oscillator) applied to FMCW(Frequency Modulated Continuous Wave)Radar as stable source is implemented and constructed with a MESFET for low noise, a dielectric resonator of high frequency selectivity, and high Q varator diode to obtain a good phase noise performance and stable sweep characteristics. The designed circuits is simulated thrash harmonic balance simulation technique to provide the optimum performance. The measured result of a fabricated VCDRO shows that output is 2.22dBm at 12.05GHz, harmonic suppression -30dBc, phase noise -130dBc at 100kHz offset, and sweep range of varator diode $\pm$18.7MHz, respectively. This oscillator will be available to FMCW Radar.

  • PDF

The 90° hybrid Coupler having the same output power slope at two output ports (두 개의 출력단자에 동일한 출력 전력 기울기를 갖는 90° hybrid Coupler)

  • Park, Ung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.85-88
    • /
    • 2016
  • Two output ports of $90^{\circ}$ hybrid-coupler are generally the same output power with $90^{\circ}$ phase difference. But, Two output ports of $90^{\circ}$ hybrid-coupler must be the different output slope characteristic about frequency because of the different electrical length. In $90^{\circ}$ hybrid-coupler being the same power distribution, 3-dB power distribution at two output ports only exists near the center frequency. And, the output power difference between two output ports increases in accordance with the further away from the center frequency. This paper proposes $90^{\circ}$ hybrid-coupler being the similar output slope characteristic of two output ports in wideband to modify the ${\lambda}/4$ transmission line of $35-{\Omega}$ characteristic impedance between input port and output port near input port. The power difference between two output ports of the proposed circuit is below 0.2dB over 20% bandwidth of the center frequency in ADS(advanced Design System).

  • PDF

Detection of a Surface-Breaking Crack Using the Surface Wave of a Laser Ultrasound (레이저 초음파의 표면파를 이용한 표면결함 측정)

  • Park, Seung-Kyu;Jung, Hyun-Kyu;Baik, Sung-Hoon;Lim, Chang-Hwan;Joo, Young-Sang;Kang, Young-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.84-89
    • /
    • 2006
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasounds by using laser beams. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this paper, we have investigated the detection techniques of a surface-breaking crack by using the laser ultrasonic surface waves. A crack acts as a low pass filter whose cut-off frequency is lowered in proportion to the depth of a crack. And, the center frequency value of a spectrum is decreased in proportion to the depth of a crack. In this paper, we extracted the crack information by using the frequency attenuation from the normalized transfer function spectrum of a surface-breaking crack. Also, we effectively measured the crack depth by using the decreasing value of the center frequency from a crack passed ultrasonic signal. The proposed measuring techniques of crack depths provided more precise information than the amplitude measuring technique.

Characteristics of Bottlenose Dolphin(Tursiops truncatus) Whistle (큰돌고래의 휘슬음 특성)

  • 신형일;서두옥;이대재;황두진;배문기;이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.271-277
    • /
    • 2002
  • This paper was described on the characteristics of bottlenose dolphin (Tursiops truncatus) whistle to develop a warning and attracting acoustic system which can be made friends woith environment and minimized to the fishing pollution from Cetaceans. The experiment for the acoustics of bottlenose dolphin whistle was carried out in dolphin performance hall at Seoul Grand Park during 18th~19th April, 2002. The frequency and the spectrum level of whistle a same pool were revealed 6~10KHz and 85㏈ but those revealed two harmonic waves a 6.7KHz and 21.3KHz for the frequency and 110㏈ and 94㏈ for the spectrum level, respectively, when a dolphin isolated from others. The range of frequency change of whistle was 3.86KHz and continuous time was 0.08 sec. The range of frequency change 10.20 KHz higher as 14.06 KHz and continuous time was 0.11sec longer as 0.19sec when a dolphin isolated from others. By the Mann-Whitney test for the result, there was a significant difference for the range of frequency change and continuous time between normal condition and when a dolphin was isolated from others. The pattern of whistle at the dolphin performance hall was five types and the frequency was getting increased slowly in the range of 5~10KHz at normal condition but there were pattern change of 5~20KHz at the isolated condition. Therefore it is thought that these experiments would be valuable for the development of acoustic system.

The Waveform and Spectrum analysis of Tursiops truncatus (Bottlenose Dolphin) Sonar Signals on the Show at the Aquarium (쇼 학습시 병코돌고래 명음의 주파수 스펙트럼 분석)

  • 윤분도;신형일;이장욱;황두진;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • The waveform and spectrum analysis of Tursiops truncatus(bottlenose dolphin) sonar signals were carried out on the basis of data collected during the dolphin show at the aquarium of Cheju Pacificland from October 1998 to February 1999. When greeting to audience, the pulse width, peak frequency and spectrum level from the five dolphins'sonar signals were 3.0ms, 4.54kHz and 125.6dB, respectively. At the time of warm-up just before the show, their figures were 5.0㎳, 5.24kHz and 127.0dB, respectively. During the performance of dolphins, with singing, peak frequency ranged 3.28∼5.78kHz and spectrum level ranged 137.0∼142.0dB. With playing ring, pulse width, peak frequency and spectrum level were 7.0㎳, 2.54kHz and 135.9dB, and when playing the ball, the values were 9.0㎳, 2.78kHz and 135.2dB, respectively. The values determined from the five dolphins during jump-up out of water were : pulse width 2.0㎳, peak frequency 4.50kHz and spectrum level 126.8dB. When they responded to trainer's instructions, the values were 2.25㎳, 248kHz and 148.7dB, respectively, and greeting to audience, the peak frequency and spectrum level were 5.84kHz and 122.5dB. During swimming under water, peak frequency and spectrum level were determined to be 10.10kHz and 126.8dB. It was found that there exited close consistencies in pulse width, frequency distribution and spectrum level between whistle sounds and dolphin's sonar signals. Accordingly, the dolphins can be easily trained by using whistle sound based on the results obtained from the waveform and spectrum of the dolphin's sonar signals.

  • PDF