• Title/Summary/Keyword: 줌렌즈

Search Result 87, Processing Time 0.022 seconds

On the Design of LED Dimming Control System for Optical Zoom Lens (광학 줌렌즈를 위한 LED 조명 제어 시스템 설계)

  • Min, Jun Hong;Kim, Min Ho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.65-70
    • /
    • 2014
  • This paper is to improve the problem of the LED dimming control system using the conventional PWM and DAC method. The conventional PWM method controls the average current to switch dimming signal. This method generates the flicker when controlling at a low current. In order to solve the problem, this system prevents the flicker with the DAC method. The LED is lit at micro-current flowing in the LED. And offset voltage is generated in the output of the DAC when the DAC output is very low voltage as 0V. This was resolved by the voltage drop of the output voltage to construct a negative offset circuit. In addition, the LED current can't flow as set values because of overheating of FET. In order to solve the problem, the 16 bits ADC in the microprocessor is a more accurate current control receives the LED current in comparison with the set value. Therefore, the LED dimming control system proposed in this paper showed the accurate and reliable more than conventional systems.

광학 분석 시스템용 수.발광 소자 집적 모듈 개발

  • Song, Hong-Ju;Lee, Jun-Ho;Park, Jong-Hwan;Han, Cheol-Gu;Park, Jeong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.311-312
    • /
    • 2012
  • 본 발표에서는 광학적 분석 시스템에 적용 가능한 발광소자(광원)과 수광소자(광센서)를 집적화시키는 모듈(수 발광 집적모듈) 기술을 제시하고자 한다. 이러한 수-발광 집적모듈은 다양한 응용 분야에 적용 될 수 있다. 예를 들어, 광신호 감지를 위한 광통신용 송-수신 모듈(optical communication), 의료/진단 분야에서 단백질/DNA/박테리아 등의 검출 및 분석에 관한 바이오 센서(bio-sensor), 그리고 대기(가스)/수질 모니터링에 관한 환경센서 등 매우 광범위한 분야에 해당되는 요소 기술이라 할 수 있다. 특히, 이들 분야들 중 바이오 물질을 분석하고 검출하는 광학적 바이오 센서 기술은 높은 경제적 가치와 산업적 성장 잠재력으로 인해 오랫동안 활발한 연구가 진행되어 오고 있다. 이러한 광학적 바이오 센서에서 가장 범용적인 방법 중 하나가 항온-항체 면역반응을 기반으로 하는 형광 검출(fluorescence detection) 기법이다. 이러한 시스템은 전체적으로 광원, 광학계, 그리고 센서로 구성되는데 기존에 일반적으로 사용되고 있는 형광 현미경의 경우는 민감도가 우수하다는 장점은 있으나 상당히 고가이고 부피가 크며 복잡한 광학구성으로 이루어져 있다는 한계점을 가지고 있다. 이러한 맥락에서 고민감도를 확보하면서 휴대성, 고속처리, 저가 등의 특성을 가진 시스템에 대한 요구가 갈수록 증가하고 있다. 이를 해결하기 위한 핵심기술 중의 하나가 수-발광 부분을 집적화 시키는 기술이라 할 수 있다. 본 연구에서는 바이오 센서 기술의 하나로서 형광을 측정하여 혈액내의 진단 지표인자를 검출할 수 있는 휴대용 혈액진단기기에 적용되는 소형 수 발광 집적 모듈을 개발하였다. 혈액내의 검출 성분의 양에 따라 형광의 세기가 변화하게 됨으로써 정량적인 검출이 가능한 원리이다. 모듈의 구조는 크게 광원(발광소자), 광학계, 그리고 광센서(수광소자) 세 영역으로 나누어 진다. 광원은 635 nm 적색 레이저다이오드로서 형광체(Alexa Fluor 647/발광파장: 668 nm)를 여기 시키는 기능을 하며 장착된 볼렌즈 의해 샘플의 형광체 영역으로 집광된다. 광학계는 크게 시준렌즈(collimating lens)와 광학필터로 구성됨으로써 샘플로부터 발생되는 광을 적절하게 수광소자로 전달하는 기능을 하게 된다. 여기서 광학필터의 경우는 기본적으로 Distributed Bragg's Reflector(DBR) 구조로써 실리콘(Si) 포토다이오드 상부에 모노리식(monolithic)하게 형성되며 검출 샘플로부터 진행되는 레이저 광(잡음의 주원인)은 차단하고 형광(광신호)만 통과 시키는 기능을 하게 된다. 따라서 신호 대 잡음비(S/N ratio)를 향상시키기 위해서는 정밀한 광 필터링 기능이 요구됨으로써 박막의 세밀한 공정 조건과 구조적-광학적 특성 분석이 수행되었다. 마지막으로 포토다이오드 소자는 일반적인 구조 이외에 중앙에 원형 구멍이 형성된 특별한 구조가 적용된다. 이것은 포토다이오드 구조에 변화를 줌으로써 모듈 구조를 효율적으로 응용할 수 있다는 의미를 갖는다. 또한 포토다이오드의 전기적-광학적 측정 분석을 통해 잡음 및 감도 특성이 세부적으로 조사되며 형광신호를 효과적으로 측정할 수 있음을 확인하였다. 최종적으로 제작된 모듈은 약 $1{\times}1{\times}1cm^3$ 내외 정도의 크기를 갖는다. 요약하자면 본 발표에서는 광학적 바이오센서에 적용할 수 있는 소형 수-발광 소자 집적모듈을 소개한다. 전체 모듈 설계는 최소한의 부피를 가짐과 동시에 측정의 정밀성을 향상시키는데 초점을 맞추어 진행하였다. 세부요소인 광학필터와 포트다이오드의 경우 잡음 및 민감도에 미치는 중요성 때문에 세밀한 공정 및 특성분석이 수행되었다. 결론적으로 독자적인 설계 및 공정을 통해 휴대성 및 정밀성 등의 목적에 부합한 경쟁력 있는 수-발광 소자 집적모듈 제작 기술을 확보하였다.

  • PDF

Camera and Receiver Development for 3D HDTV Broadcasting (3차원 고화질TV 방송용 카메라 및 수신기 개발)

  • 이광순;허남호;안충현
    • Journal of Broadcast Engineering
    • /
    • v.7 no.3
    • /
    • pp.211-218
    • /
    • 2002
  • This paper introduces the HD 3DTV camera and 3DTV receiver that are compatible with the ATSC HDTV broadcasting system. The developed 3DTV camera is based on stereoscopic techniques, and it has control function to control both left and right zoom lens simultaneously and to control the vergence. Moreover, in order to control the vergence manually and to eliminate the synchronization problem of the both images, the 3DTV camera has the 3DTV video multiplexing function to combine the left and right images into the single image. The developed 3DTV signal, and it has the various analog/digital interfaces. The performance of the developed system is confirmed by shooting the selected soccer game in 2002 FIFA KOREA/JAPANTM World Cup and by broadcasting the match. The HD 3DTV camera and receiver will be applied to the 3DTV industries such as 3D movie, 3D game, 3D image processing, 3DTV broadcasting system, and so on.

Out-of-Plane Deformation Measurement of TPS in Vehicle Using ESPI (ESPI를 이용한 자동차 TPS 면외변형 계측)

  • Han, Sang-Kil;Ham, Hyo-Shick;Ham, Sang-Hyun;Lee, Jong-Hwang;Jung, Won-Wook;Lee, Chang-Hee;Lee, Sang-Bong;Choi, Sung-Eul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.423-428
    • /
    • 2010
  • In this paper, we analyzed the characteristics of thermal deformation of the TPS which is a core part of engine in vehicle by measuring out-of-plane deformation using ESP!. Inspection area of a test piece was minimized to 5 cm by 5 cm by using a high resolution CCD and a zoom lens. 4-step phase shifting method was used along with phase unwrapping algorithm to get a continuous phase map, configurations and deformations were displayed as 3D images. When heating the test pieces while maintaining the temperature at about $70^{\circ}C$, the out-of-plane deformations were measured. The results showed that a test piece with longer distance traveled tends to show larger thermal deformation, we could observes a convex shaped deformation on the surface. The inner defect sample, we could monitor discontinuous pattern phase map, and a concave shaped deformation on the surface.

Effect of Injection Angle and Length to Diameter Ratios on Drop and Penetration Characteristics in Cross-flow (아름속 횡단 기체 유동장에서 노즐 형상 변화와 분사각 변화가 액적크기와 침투거리에 미치는 영향)

  • Lee, Bong-Soo;Ko, Jung-Bin;Cho, Woo-Jin;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.51-58
    • /
    • 2006
  • The spray characteristics of liquid jet injected into subsonic cross-flow were investigated experimentally. Spray trajectories were captured using CCD camera. Droplet sizes were measured using PDPA and Image Express. The nozzle diameter was 0.5 mm, and its length-to-diameter ratios (L/D) ran$4.11{\times}10^6$ged from 1.0 to 6.0. Experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration length is decreased by increasing Weber number. At low injection angle(${\theta}$ < $90^{\circ}$), Weber number is dominant parameter for trajectories, but at high injection angle(${\theta}$ > $90^{\circ}$), L/D is dominant parameter for trajectories rather than Weber number.

DOF Correction of Heterogeneous Stereoscopic Cameras (이종 입체영상 카메라의 피사계심도 일치화)

  • Choi, Sung-In;Park, Soon-Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.169-179
    • /
    • 2014
  • In this paper, we propose a DOF (Depth of Field) correction technique by determining the values of the internal parameters of a 3-D camera which consists of stereoscopic cameras of different optical properties. If there is any difference in the size or the depth range of focused objects in the left and right stereoscopic images, it could cause visual fatigue to human viewers. The object size of in the stereoscopic image is corrected by the LUT of zoom lenses, and the forward and backward DOF are corrected by the object distance. Then the F-numbers are determined to adjust the optical properties of the camera for DOF correction. By applying the proposed technique to a main-sub type 3-D camera using a GUI-based DOF simulator, the DOF of the camera is automatically corrected.

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF