• 제목/요약/키워드: 준능동 MR 감쇠기

검색결과 25건 처리시간 0.019초

준능동 MR 감쇠기를 이용한 인접빌딩의 지진응답 퍼지제어 (Seismic Response Fuzzy Control of Adjacent Building using Semi-active MR Dampers)

  • 옥승용;김동석;박관순;고현무
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.495-502
    • /
    • 2006
  • Seismic performance of semi-active fuzzy control algorithm to operate MR dampers for coupling adjacent building is investigated in this paper. In the proposed semi-active control technique, the fuzzy logic is used as a method to adjust input voltage to MR damper. In order to validate control performance of proposed technique, the seismic performance of the semi-active fuzzy control system is compared with that of passive control system where the input voltage to MR damper is set to display maximum damping force. The simulated results show that the semi-active fuzzy control technique effectively regulates the trade-off existing between seismic responses of two buildings subject to various earthquake excitations.

  • PDF

유전자알고리즘을 이용한 스마트 면진시스템의 퍼지제어 (Fuzzy Control of Smart Base Isolation System using Genetic Algorithm)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권2호통권42호
    • /
    • pp.37-46
    • /
    • 2005
  • 현재까지 많은 스마트 면진시스템이 제안되었고 연구되어 왔다. 본 연구에서는 스마트 면진시스템의 면진장치와 보조감쇠 장치로서 새로운 형태의 마찰진자시스템(FPS)과 MR 감쇠기를 각각 사용한다. 퍼지로직제어기(FLC)가 고유의 견실성과 비선형 및 불확실성을 쉽게 다룰 수 있는 능력이 있기 때문에 MR 감쇠기의 감쇠력을 조절하는데 FLC를 사용한다. 또한 FLC의 성능을 최적화 하기 위해서는 유전자알고리즘(GA)을 사용한다. GA를 사용함으로써 소속함수의 형상을 조절하는 것뿐만 아니라 적절한 퍼지제어규칙을 결정할 수 있다. 이를 위하여 본 연구에서는 부분개선 유전자알고리즘을 사용하였다. 이 방법은 유전자의 특정부분을 향상시키는데 효율적이다. FPS와 MR 감쇠기의 동적거동을 표현하기 위해서는 뉴로?퍼지 모델을 사용한다. FLC의 최적설계를 위하여 본 연구에서 제안된 방법의 효율성은 여러 가지 역사지진을 사용하여 계산된 동적응답을 기초로 하여 평가한다. 예제해석결과 제안된 방법은 적절한 퍼지규칙을 찾을 수 있고 GA로 최적화된 FLC는 수동제어기 뿐만 아니라 전문가의 지식에 기반한 FLC와 전통적인 준능동제어기보다 더 좋은 성능을 발휘한다.

추계학적 선형화 방법 및 다목적 유전자 알고리즘을 이용한 지진하중을 받는 인접 구조물에 대한 비선형 감쇠시스템의 최적 설계 (Optimal design of nonlinear damping system for seismically-excited adjacent structures using multi-objective genetic algorithm integrated with stochastic linearization method)

  • 옥승용;송준호;고현무;박관순
    • 한국지진공학회논문집
    • /
    • 제11권6호
    • /
    • pp.1-14
    • /
    • 2007
  • 인접 구조물의 지진응답 제어를 위한 비선형 감쇠시스템의 최적 설계 방법에 관하여 연구하였다. 최적 설계를 위한 목적 함수로는 구조물의 응답과 감쇠기의 총 사용량을 고려하였으며, 상충하는 두 목적함수를 합리적인 수준에서 동시에 최소화하는 해를 구하기 위하여 유전자 알고리즘에 기반한 다목적 최적화 방법을 도입하였다. 또한, 최적화 과정에서 요구되는 비선형 시간이력해석을 수행하지 않고도, 비선형 이력감쇠기로 연결된 구조물의 지진응답을 효율적으로 평가하기 위하여 추계학적 선형화 방법을 접목하였다. 제시하는 방법의 효율성을 검증하기 위한 수치 예로서 20층과 10층의 인접 빌딩을 고려하였으며, 두 빌딩을 연결하는 비선형 감쇠시스템으로는 입력전압의 크기에 따라 변화하는 감쇠성능을 보이는 MR 감쇠기를 도입하였다. 제시하는 방법을 통하여 MR 감쇠기의 각 층별 최적 개수 및 감쇠용량을 결정할 수 있었으며, 이는 일반적인 균등분포 시스템에 비해 유사한 제어성능을 보이면서도 훨씬 경제적이었다. 또한, 인접구조물간 충돌에 대하여도 확률적으로 안정적인 거동을 보임을 검증하였으며, 제시하는 방법이 준능동 제어시스템의 최적 배치를 결정하기 위한 설계문제에도 적용할 수 있음을 보였다.

준능동 스마트 감쇠기를 사용한 빌딩구조물의 지진응답제어 (Seismic Response Control of Building Structures using Semiactive Smart Dampers)

  • 김현수;;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.451-458
    • /
    • 2006
  • The goal of many researchers in the field of structural engineering is to reduce both damage to building structures and discomfort of their inhabitants during strong motion seismic events. The present paper reports on analytical work conducted with this aim in mind as a prior research of experimental study. A four-story, 6.4 m tall, laboratory model of a building is employed as a example structure. The laboratory structure has graphite epoxy columns and each floor is equipped with a chevron brace that serves to resist inter-story drift with the installation of a magnetorheological (MR) damper. An artificial excitation has been generated with a robust range of seismic characteristics. A series of numerical simulations demonstrates that an optimized fuzzy controller is capable of robust performance for a variety of seismic base motions. Optimization of the fuzzy controller is achieved using multi-objective genetic algorithm(MOGA), i.e. NSGA-II. Multiple objective functions are used in order to reduce both peak and root-means-squared displacement and accelerations at the floor levels of the building.

  • PDF

인접구조물의 내진성능개선을 위한 준능동 MR감쇠기의 GA-최적퍼지제어 (GA-based Optimal Fuzzy Control of Semi-Active Magneto-Rheological Dampers for Seismic Performance Improvement of Adjacent Structures)

  • 윤중원;박관순;옥승용
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.69-79
    • /
    • 2011
  • This paper proposes a GA-based optimal fuzzy control technique for the vibration control of earthquakeexcited adjacent structures interconnected with semi-active magneto-rheological(MR) dampers. Rule-based fuzzy logic controllers are designed first by implementing heuristic knowledge and the genetic algorithm(GA) is then introduced to optimally tune the fuzzy controllers for enhancing the seismic performance of semi-active control system. For practical implementation, the fuzzy controller simply uses locally measured responses of the dampers involved and directly returns the input voltage to the magneto-rheological dampers in real time through the fuzzy inference mechanism. The local measurement based fuzzy controller provides optimal damping force in a decentralized manner so that it does not require a primary central controller unlike the conventional semi-active control techniques. As a result, it can avoid the unbridgeable discrepancy between the desired control force and the actual damper force that may occur in the conventional control approaches. The validity and effectiveness of the proposed control method are shown numerically on two 20-story earthquake-excited buildings interconnected with MR dampers.