• Title/Summary/Keyword: 주파수분석

Search Result 5,640, Processing Time 0.032 seconds

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

A Study on the Dental Hygienists' Reactions to Noise When Occurred in Dental Clinic (치과병원에서 발생하는 소음에 대한 치과위생사의 반응)

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.453-459
    • /
    • 2009
  • The purposes of this research were to evaluate the relationships of between characteristics of noise and annoyance of dental hygienist by noise in dental clinic. To investigate the dental clinic workers' reactions to noise when occurred in dental clinic, the noise level test in dental clinic and questionnaire were taken. As a result of noise evaluation, It shows that the range of noise level was 67.7~78.3dB(A) and frequency was very high (more than 4KHz). It's seem to be begins occurrence of stamina-loss, contraction of peripheral blood vessel, decrease of adrenocortical hormones. Most of respondents were affected by noise: 67% of respondents were nervous about noise and the rest of respondents were bearable. Analysis by NR-curve showed that it was exceed the noise permit level in working space. As a result of correlation - test, the more exposed dental hygienist to noise, the more felt the unpleasantness and fatigue. It's hard to sufficient explanation to patients about the dental treatment. So it's thoughts that insufficient explanation will negative impact on the patients' satisfaction and increase competitiveness in dental clinics. To remedy a unpleasantness and fatigue of noise in dental hygienist, it's considered that making an offer the ear protection and choosing the low noise-vib. equipment and using the masking effect. Therefore, It can be provide a pleasant working environment with dental hygienist and It will have a great advantage to dental clinics to improve their competitiveness.

  • PDF

The effect of palatal height on the Korean vowels (구개의 높이가 한국어 모음 발음에 미치는 효과에 관한 연구)

  • Chung, Bo-Yoon;Lim, Young-Jun;Kim, Myung-Joo;Nam, Shin-Eun;Lee, Seung-Pyo;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose: The purpose of this study was to analyze the influence of palatal height on Korean vowels and speech intelligibility in Korean adults and to produce baseline data for future prosthodontic treatment. Material and methods: Forty one healthy Korean men and women who had no problem in pronunciation, hearing, and communication and had no history of airway disease participated in this study. Subjects were classified into H, M, and L groups after clinical determination of palatal height with study casts. Seven Korean vowels were used as sample vowels and subjects'clear speech sounds were recorded using Multispeech software program on computer. The F1 and the F2 of 3 groups were produced and they were compared. In addition, the vowel working spaces of 3 groups by /a/, /i/, and /u/ corner vowels were obtained and their areas were compared. Kruskal-Wallis test and Mann-Whiteny U test were used as statistical methods and P < .05 was considered statistically significant. Results: There were no significant differences in formant frequencies among 3 groups except for the F2 formant frequency between H and L group (P = .003). In the analysis of vowel working space areas of 3 groups, the vowel working spaces of 3 groups were similar in shape and no significant differences of their areas were found. Conclusion: The palatal height did not affect vowel frequencies in most of the vowels and speech intelligibility. The dynamics of tongue activity seems to compensate the morphological difference.

A Review Essay on Legal Mechanisms for Orbital Slot Allocation (정지궤도슬롯의 법적 배분기제에 관한 논고)

  • Jung, Joon-Sik;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.29 no.1
    • /
    • pp.199-236
    • /
    • 2014
  • This paper analyses from the perspective of distributive justice the legal mechanisms for international allocation of orbital slots, which are of co-owned nature and thereby limited natural resources in outer space. The allocative function is delegated to the International Telecommunication Union. The Radio Regulation, amongst such other legal instruments as the Constitution and Convention, by which the ITU and contracting States thereof abides, dictates how the orbital positions are distributed. Thus, the RR is thoroughly reviewed in the essay. The mechanisms are in a broad sense categorized into two systems: 'a posteriori system' where the 'first come, first served' principle prevails; and 'a priori system' designed to foster the utilisation of the slots by those who lack space resources and are, in especial, likely to be marginalised under the former system. The argument proceeds on the premise that a posteriori system places the under-resourced States in unfavourable positions in the securement of the slots. In contrast with this notion, seven factors were instantiated for an assertion that the degradation of the distributive justice derived from the 'first come, first served' rule, which lays the foundation for the system, could be either mitigated or counterbalanced by the alleged exceptions to the rule. However, the author of this essay argues for counterevidences against the factors and thereby demonstrating that the principle still remains as an overwhelming doctrine, posing a threat to the pursuit of fair allocation. The elements he set forth are as in the following: 1) that the 'first come, first served' principle only applies to assignments capable of causing harmful interferences; 2) the interoperability of the principle with the 'rule of conformity' with the all the ITU instruments; 3) the viability of alternative registrations, as an exception of the application of the principle, on the condition of provisional and informational purposes; 4) another reference that matters in deciding the priority: the types of services in the TFA; 5) the Rule of Procedure H40 proclaiming a ban on taking advantage of coming first to the Register; 6) the technical factors and equity-oriented norms under international and municipal laws along with; 7) the changes of 'basic characteristics' of registered assignments. The second half of this essay illustrates by examining the relevant Annexes to the Regulation that the planned allocation, i.e., a priori system, bear the structured flaws that hinder the fulfillment of the original purpose of the system. The Broadcasting and Fixed Satellite Systems are the reviewed Plans in which the 'first come, first served' principle re-emerges in the end as a determining factor to grant the 'right to international recognition' to administrations including those who has not the allotted portions in the Plan.

Quantitative Electroencephalogram Markers for Predicting Cerebral Amyloid Pathology in Non-Demented Older Individuals With Depression: A Preliminary Study (비치매 노인 우울증 환자에서 대뇌 아밀로이드 병리 예측을 위한 정량화 뇌파 지표: 예비연구)

  • Park, Seon Young;Chae, Soohyun;Park, Jinsick;Lee, Dong Young;Park, Jee Eun
    • Sleep Medicine and Psychophysiology
    • /
    • v.28 no.2
    • /
    • pp.78-85
    • /
    • 2021
  • Objectives: When elderly patients show depressive symptoms, discrimination between depressive disorder and prodromal phase of Alzheimer's disease is important. We tested whether a quantitative electroencephalogram (qEEG) marker was associated with cerebral amyloid-β (Aβ) deposition in older adults with depression. Methods: Non-demented older individuals (≥ 55years) diagnosed with depression were included in the analyses (n = 63; 76.2% female; mean age ± standard deviation 73.7 ± 6.87 years). The participants were divided into Aβ+ (n = 32) and Aβ- (n = 31) groups based on amyloid PET assessment. EEG was recorded during the 7min eye-closed (EC) phase and 3min eye-open (EO) phase, and all EEG data were analyzed using Fourier transform spectral analysis. We tested interaction effects among Aβ positivity, condition (EC vs. EO), laterality (left, midline, or right), and polarity (frontal, central, or posterior) for EEG alpha band power. Then, the EC-to-EO alpha reactivity index (ARI) was examined as a neurophysiological marker for predicting Aβ+ in depressed older adults. Results: The mean power spectral density of the alpha band in EO phase showed a significant difference between the Aβ+ and Aβ- groups (F = 6.258, p = 0.015). A significant 3-way interaction was observed among Aβ positivity, condition, and laterality on alpha-band power after adjusting for age, sex, educational years, global cognitive function, medication use, and white matter hyperintensities on MRI (F = 3.720, p = 0.030). However, post-hoc analyses showed no significant difference in ARI according to Aβ status in any regions of interest. Conclusion: Among older adults with depression, increased power in EO phase alpha band was associated with Aβ positivity. However, EC-to-EO ARI was not confirmed as a predictor for Aβ+ in depressed older individuals. Future studies with larger samples are needed to confirm our results.

SANET-CC : Zone IP Allocation Protocol for Offshore Networks (SANET-CC : 해상 네트워크를 위한 구역 IP 할당 프로토콜)

  • Bae, Kyoung Yul;Cho, Moon Ki
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.87-109
    • /
    • 2020
  • Currently, thanks to the major stride made in developing wired and wireless communication technology, a variety of IT services are available on land. This trend is leading to an increasing demand for IT services to vessels on the water as well. And it is expected that the request for various IT services such as two-way digital data transmission, Web, APP, etc. is on the rise to the extent that they are available on land. However, while a high-speed information communication network is easily accessible on land because it is based upon a fixed infrastructure like an AP and a base station, it is not the case on the water. As a result, a radio communication network-based voice communication service is usually used at sea. To solve this problem, an additional frequency for digital data exchange was allocated, and a ship ad-hoc network (SANET) was proposed that can be utilized by using this frequency. Instead of satellite communication that costs a lot in installation and usage, SANET was developed to provide various IT services to ships based on IP in the sea. Connectivity between land base stations and ships is important in the SANET. To have this connection, a ship must be a member of the network with its IP address assigned. This paper proposes a SANET-CC protocol that allows ships to be assigned their own IP address. SANET-CC propagates several non-overlapping IP addresses through the entire network from land base stations to ships in the form of the tree. Ships allocate their own IP addresses through the exchange of simple requests and response messages with land base stations or M-ships that can allocate IP addresses. Therefore, SANET-CC can eliminate the IP collision prevention (Duplicate Address Detection) process and the process of network separation or integration caused by the movement of the ship. Various simulations were performed to verify the applicability of this protocol to SANET. The outcome of such simulations shows us the following. First, using SANET-CC, about 91% of the ships in the network were able to receive IP addresses under any circumstances. It is 6% higher than the existing studies. And it suggests that if variables are adjusted to each port's environment, it may show further improved results. Second, this work shows us that it takes all vessels an average of 10 seconds to receive IP addresses regardless of conditions. It represents a 50% decrease in time compared to the average of 20 seconds in the previous study. Also Besides, taking it into account that when existing studies were on 50 to 200 vessels, this study on 100 to 400 vessels, the efficiency can be much higher. Third, existing studies have not been able to derive optimal values according to variables. This is because it does not have a consistent pattern depending on the variable. This means that optimal variables values cannot be set for each port under diverse environments. This paper, however, shows us that the result values from the variables exhibit a consistent pattern. This is significant in that it can be applied to each port by adjusting the variable values. It was also confirmed that regardless of the number of ships, the IP allocation ratio was the most efficient at about 96 percent if the waiting time after the IP request was 75ms, and that the tree structure could maintain a stable network configuration when the number of IPs was over 30000. Fourth, this study can be used to design a network for supporting intelligent maritime control systems and services offshore, instead of satellite communication. And if LTE-M is set up, it is possible to use it for various intelligent services.

GPR Development for Landmine Detection (지뢰탐지를 위한 GPR 시스템의 개발)

  • Sato, Motoyuki;Fujiwara, Jun;Feng, Xuan;Zhou, Zheng-Shu;Kobayashi, Takao
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.270-279
    • /
    • 2005
  • Under the research project supported by Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT), we have conducted the development of GPR systems for landmine detection. Until 2005, we have finished development of two prototype GPR systems, namely ALIS (Advanced Landmine Imaging System) and SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar). ALIS is a novel landmine detection sensor system combined with a metal detector and GPR. This is a hand-held equipment, which has a sensor position tracking system, and can visualize the sensor output in real time. In order to achieve the sensor tracking system, ALIS needs only one CCD camera attached on the sensor handle. The CCD image is superimposed with the GPR and metal detector signal, and the detection and identification of buried targets is quite easy and reliable. Field evaluation test of ALIS was conducted in December 2004 in Afghanistan, and we demonstrated that it can detect buried antipersonnel landmines, and can also discriminate metal fragments from landmines. SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar) is a machine mounted sensor system composed of B GPR and a metal detector. The GPR employs an array antenna for advanced signal processing for better subsurface imaging. SAR-GPR combined with synthetic aperture radar algorithm, can suppress clutter and can image buried objects in strongly inhomogeneous material. SAR-GPR is a stepped frequency radar system, whose RF component is a newly developed compact vector network analyzers. The size of the system is 30cm x 30cm x 30 cm, composed from six Vivaldi antennas and three vector network analyzers. The weight of the system is 17 kg, and it can be mounted on a robotic arm on a small unmanned vehicle. The field test of this system was carried out in March 2005 in Japan.

Heart Rate Variability and Parenting Stress Index in Children with Attention-Deficit/Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서의 심박 변이도와 양육 스트레스)

  • Kim, Soo-Young;Lee, Moon-Soo;Yang, Jae-Won;Jung, In-Kwa
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.19 no.2
    • /
    • pp.74-82
    • /
    • 2011
  • Objective:The aim of this study was to evaluate the relationship between sustained attention deficits in Attention-Deficit/Hyperactivity Disorder(ADHD) children and short-term Heart Rate Variability(HRV) parameters. In addition, we evaluate the relationship between The ADHD rating scale(ARS), the computerized ADHD diagnostic system(ADS) and Parenting stress index- short form(PSI-SF). Methods:This study was performed in the department of children and Adolescent psychiatry, Korea university Guro hospital from august 2008 to January 2009. We evaluated HRV parameters by short-term recordings of 5 minutes. K-ARS and ADS are used for screening and identifying ADHD children. Intelligence was measured using Korean educational Developmental Institute-wechsler Intelligence Scale for Children. The caregivers Complete Parenting Stress Index scale for evaluation parent stress. Results:The low frequency(LF) was significantly correlated with response variability of ADS. However, the other variables of ARS and ADS were not significantly correlated with LF. Hyperactivity subscale of ARS was significantly correlated with parental distress subscale and difficult child subscale of PSI-SF and inattention subscale of ARS was also significantly correlated with dysfunctional interaction and difficult child subscale of PSI-SF. Conclusion:The LF, 0.10-Hz component of HRV is known to measure effort allocation. This study shows that the LF component of HRV is significantly correlated with the response variability of ADS. This means that more severe symptoms of ADHD were correlated with the increase in the LF that means decreased effort allocation. These results also support the clinical usability of HRV in the assessment of ADHD. Furthermore, PSI-SF is correlated with hyperactivity and inattention variables of ARS.

  • PDF

The Change of Heart Rate Variability in Anxiety Disorder after Given Physical or Psychological Stress (불안장애 환자에서 육체적 및 정신적 스트레스 시 심박변이도의 변화)

  • Cho, Min-Kyung;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • Objectives: This study was designed to assess the change of heart rate variability (HRV) at resting, upright, and psychological stress in anxiety disorder patients. Methods: HRV was measured at resting, upright, and psychological stress states in 60 anxiety disorder patients. We used visual analogue scale (VAS) score to assess tension and stress severity. Beck depression inventory (BDI) and state trait anxiety inventories I and II (STAI-I and II) were used to assess depression and anxiety severity. Differences between HRV indices were evaluated using paired t-tests. Gender difference analysis was accomplished with ANCOVA. Results: SDNN (Standard deviation of normal RR intervals) and low frequency/high frequency (LF/HF) were significantly increased, while NN50, pNN50, and normalized HF (nHF) were significantly decreased in the upright position compared to resting state (p < 0.01). SDNN, root mean square of the differences of successive normal to normal intervals, and LF/HF were significantly increased, while nHF was significantly decreased in the psychological stress state compared to resting state (p < 0.01). SDNN, NN50, pNN50 were significantly lower in upright position compared to psychological stress and nVLF, nLF, nHF, and LF/HF showed no significant differences between them. Conclusion: The LF/HF ratio was significantly increased after both physical and psychological stress in anxiety disorder, but did not show a significant difference between these two stresses. Significant differences of SDNN, NN50, and pNN50 without any differences of nVLF, nLF, nHF, and LF/HF between two stresses might suggest that frequency domain analysis is more specific than time domain analysis.

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • Park, Jung Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.8-8
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100μm and 11mm/sec, and were the smallest at the compass deck with 3μm and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).