• Title/Summary/Keyword: 주택성능

Search Result 600, Processing Time 0.025 seconds

Proposal of PC Core System for Modular Housing (모듈러주택 적용을 위한 PC코어 시스템 제안)

  • Minjun, Kim
    • Land and Housing Review
    • /
    • v.14 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • Modular construction is popular as a smart building system because it can shorten the construction period. This study proposed a precast concrete (PC) core system that can further shorten modular construction time. The system was developed and its structural performance was verified through computational analysis. The proposed PC core system is a complete PC construction method using dry bonding. The results of the study indicated that the proposed PC core system has structural stability and performance suitable for modular housing.

A Study on Evaluation Plan of Fire Safety Performance for Public Building (공동주택의 화재안전성능 평가방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2019
  • From the viewpoint of fire-fighting activities, public building have structural and management problems in fire, so evacuation disturbance and risk of expanding combustion are high. As a result of analyzing various fire fragile factors of public building, The evaluation areas were derived from safety systems, fire-fighting facility, structure safety, general safety and the evaluation factors were presented. Also, the characteristics of domestic and foreign certification systems were analyzed by comparing and analyzing the status of fire safety performance certification system for 6 domestic and overseas apartment houses. In conclusion, the 5 convergence directions of certification system and 22 evaluation items by 4 evaluation fields were derived, and based on this, we have established 3 convergence introduction plans of fire safety performance certification system of public building.

욕실 층상 이중배관 시스템 개발-(주)청완산업

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.11 s.208
    • /
    • pp.78-82
    • /
    • 2007
  • 내년 1월부터 2,000세대 이상 공동주택을 건설하는 사업주는 입주자 모집공고안에 주택에 대한 성능등급(주택의 소음, 구조, 환경, 생활환경 등급, 평가 항목에 따라 1-5등급으로 구분)을 미리 표시해야 한다. 이에 따라 건설업체는 성능등급을 받은 자재를 선호할 것으로 보여져 성능등급을 받은 자재에 대한 관심이 높아질 전망이다. (주)청완산업이 새로 개발한 Double Up System은 화장실 소음 1등급과 구조부문 수리용이성 1등급을 획득, 건설업계의 러브콜이 예상된다. 또한 욕실 배관을 층상배관으로 시공 함으로써 시공의 용이성과 함께 소음걱정 해소, 쾌적한 환경 및 다양한 인테리어가 기대된다.

  • PDF

주택성능등급 표시제도

  • Kim, Yong-In
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.36 no.4
    • /
    • pp.23-33
    • /
    • 2007
  • 2006년 1월부터 실시되고 있는 주택성능등급 표시제도에 대하여 알아보고자 한다.

  • PDF

A Study for Standard of Performance Evaluation of Remodeling Apartments House -Focused on Comparative Analysis of Performance Evaluation Criteria between korea and Japan- (리모델링 공동주택의 성능평가 기준 마련을 위한 이론 고찰 -한국과 일본의 성능평가 기준 비교.분석을 중심으로-)

  • Lee, Yong-Hyun;Lee, Jong-Sik;Lee, Jea-Sauk;Chun, Jae-Youl
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.868-871
    • /
    • 2008
  • Remodeling is an architectural activity that transforms the existing state of specific building which has been aged and clichedinto new state overcoming those aged and cliched state. Remodeling can be a means to increase building's physical lifecycle and also a countermeasure to cope with the changes in use that are from social demand, use and technical development. The performance evaluation on the remodeling tenement shall be done by understanding the performance and state of the building before and after remodeling and then it shall represent the improvement in performance objectively by comparing the differences before and after remodeling. In this aspect, we performed basic research to conduct performance evaluation on the remodeling tenement by comparing and analyzing the performance evaluation and performance certificate systems of Korea and Japan in order to suggest objective evaluation system on the change of tenement building before and after remodeling.

  • PDF

The Analysis on Energy Performance Index of the Green Building Certified Apartment Buildings in Korea (공동주택 친환경인증단지의 에너지성능지표 비교분석 연구)

  • Kim, Jong-Yeob;Jung, Yoon-Hye;Paik, Hae-Sun
    • Land and Housing Review
    • /
    • v.4 no.4
    • /
    • pp.407-415
    • /
    • 2013
  • Although many certification works have been carried out since Green Building Certification was enforced in 2002, analyses of the effects and efforts to improve this system are still poor. In the certification system, the energy performance was usually assessed by Energy Performance Index(EPI) of the Energy Saving Design Standards for Buildings. However, due to the inadequacy of analyses on current situation of the Index, there are difficulties to reform it. In this research of green-certified apartments, the author examined correlations between energy performance indexes and aimed to improve the Index by analyzing the scores based on point distribution of respective fields. The average EPI score of green-certified apartments was 74.68, and there was wide variations in min 63.4 and max 90. Furthermore, the average score of energy consumption, which was allotted the most points, was 7.04 out of 12. Therefore, betterments in the Index such as reinforcement in grade ranges and adjustment of the calculation method are necessary.

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.

제도 & 시행 (1) - 노후 공공임대주택 그린홈으로 리모델링

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.239
    • /
    • pp.24-25
    • /
    • 2010
  • 국토해양부(장관 정종환)는 한국토지주택공사(LH)의 노후 영구임대주택 중 7개 단지, 8,808세대를 대상으로 지난 4월 23일부터 그린홈 시범사업(120억)에 들어갔다. 2025년까지 제로에너지 주택건설을 목표로 한 저탄소 녹색성장을 위한 그린홈 건설추진 사업의 일환으로 지난 해 10월 신규 공동주택(20세대 이상)에 대해 그린홈 건설을 의무화[("친환경 주택 건설기준 및 성능"('09.10월 국토해양부 고시)] 하는 건설기준이 마련되었다. 이에 따라 국토부는 기존주택의 그린홈화를 위해 금년부터 우선적으로 공공부문의 노후화된 영구임대주택을 그린홈 개선 시범사업으로 개보수 시행에 들어간다고 밝혔다.

  • PDF

Insulation Performance Analysis of Vulnerable Parts of Thermal Bridge and Condensation in Modular Buildings (모듈러 주택의 열교 및 결로 취약부위별 단열성능 분석)

  • Kim, Miyeon;Kim, Hyunggeun;Park, Jinchul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.3
    • /
    • pp.31-39
    • /
    • 2021
  • The modular construction method is an off-site construction method using built-in structures from the manufacturing facilities. Modular construction is commonly applied to buildings which have relatively smaller and simpler structures than other types of buildings. Although modular building has emerged in the domestic construction industry as an alternative building strategy, previous researches on the environmental characteristics of modular building has not been comprehensively studied. Thus, this study empirically analyzed the insulation performance of thermal bridge and condensation parts of the modular buildings by using IR image analysis, Air-Surface Temperature Ratio method, and temperature difference ratio. The insulation performance analysis was conducted by comparing a modular building and a RC building in Seoul. The results shows that there was no significant difference between insulation performances of RC building and modular building. Furthermore