• Title/Summary/Keyword: 주입공기온도

Search Result 97, Processing Time 0.041 seconds

Study on the Productivity of Microalgae Nannochloropsis sp. Using the Highly Efficient Vertical Photobioractor (수직형 고효율 광배양기를 통한 미세조류 Nannochloropsis sp.의 생장성 연구)

  • Kim, Young-Nam;Chung, Myung-Hee;Kim, Eun-Joo;Karnadi, Vita;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • We have investigated the productivity of microalgae, Nannochloropsis sp., using highly efficient vertical photobioreactor which has been developed by the company IMBiz. This experiment was performed in the field for one month with 2 sets of 2 tons of media under autotrophic cultural mode. In the culture with 0.1% of $CO_2$, the average daily productivity was shown to be up to 0.953g per liter, and 0.574g per liter in the culture with only ambient air. The temperature ranged from $20^{\circ}C$ to $31^{\circ}C$, and it didn't make any differences on the productivity. The light intensity ranged from 5,000 Lux to 40,000 Lux. The light has been appeared to have a very close relationship with the productivity of microalgae. Meanwhile, the harvesting method of pressurefloating attempted in this photobioreactor was found to be very effective.

디젤류가 오염된 토양에서 공기주입법으로 처리한 토양 판별 인자들의 변화

  • Kim, Yeong-Am;No, Jong-Su;Lee, Dong-Seon;Lee, Yong-Hui
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.110-114
    • /
    • 2005
  • 인공적으로 디젤류에 오염시킨 5kg의 토양이 충전된 두 개의 실험 column을 이용해서 외부 온도변화 효과를 최소화하기 위해서 $25^{\circ}C{\pm}2.5$로 유지시켰으며, 유량속도도 10ml/min로 일정하게 유지시켰다. 또한 수분은 활동범위 능력의 $60{\sim}80%$에서 유지시켰다. 따라서 연속식과 간헐 주입식 모드를 운전비용의 감소 및 효율의 향상 측면에서 모드의 평가를 위한 방법으로 이용기간 동안 총세균 수, 유류분해균 수의 변화, 탈수소효소 활성도의 변화 추이 분석을 하였다. 두 venting 모드별로 본 총 종속영양균 수와 유류분해균 수는 모두 대등한 성장률을 보였으며, 반응일 수에 따라 비교된 탈수소효소 활성도 반응 90일 동안 비슷한 활성을 유지 했다.

  • PDF

Brevibacterium sp.에 의한 L-leucine의 생산에 관한 연구

  • 정병하;황두연
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1978.04a
    • /
    • pp.96.3-96
    • /
    • 1978
  • Biotin 요구성 glutamic acid 생산능을 가진 Br-evibacterium sp.의 isoleucine 영양요구성 변이주가 다량의 L-leucine을 생성함을 발견하였다. 본균주에 관한 탄소원, 질소원, 무기염, vitamin, amino acid 등의 영양물질과 온도, 공기주입량, pH등에 관한 실험으로 다음과 같은 결과를 얻었다. 본균주는 탄소원, 질소원으로서 10% glucose와 4% $(NH_4)_2SO_4를$ 공합하여 $30^{\circ}C,$ 88시간 배양시킨 결과, 액중에 21 mg/ml의 L-leucine이 축적되었다. Fe$^{2+}$$Mn^{2+}$의 동시첨가는 L-leucine생성에 효과적이었으며 thiamine 역시 L-leucine 생성에 효과적이었다. 30ι jar fermentor 에서 폐당밀을 주원료로 한 실험결과, 폐당밀, $(NH_4)/SO_4,$ $KH_2PO_4,$ $MgSO_4ㆍ7H_2O로$ 구성된 액체배지에서 $30^{\circ}C,$ 36시간 배양시킨 것이, 27mg/ml의 L-leucine이 축적되었으며 이때의 대당수율은 16%이었다.

  • PDF

A Study of Staged Swirling Combustion of Natural gas (천연가스 다단연소기술 연구)

  • 이진홍;목영일
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.115-125
    • /
    • 1995
  • 본“천연가스 다단연소기술 연구”는, 공업적으로 널리 쓰이는 선회확산 방식으로 천연가스를 연소시킬 때 그 연소 특성과 발생되는 환경오염물질인 일산화탄소(CO)와 질소산화물(NOX)의 저감에 대한 연구로서, 천연가스의 난류확산화염과 선회확산화염의 유동장, 온도장, 농도장을 실험과 수치해석을 통하여 분석하여 각각 연소방식의 화염구조와 특성을 규명하고 해석하였다. 그리고 그 결과를 토대로하여 다단확산 연소실험 장치를 제작 다단확산연소의 중요한 인자인 1차당량비, 2차공기주입위치, 유속, 선회도 등을 변화시켜 질소산화물 저감과 높은 연소효율을 얻을 수 있는 최적의 연소조건을 찾아 내었다. 본고에서는 실험부분만을 간추려 발표하고 수치해석 부분은 다음 기회로 미루고자 한다.

  • PDF

Evaluation of Destratification Efficiency by Combined Effect of Adjacent Plumes through 2-Phase and 3D Hydrodynamic Analysis in a Stratified Fluid (Bubble plume의 중첩효과가 저수지 성층파괴 효율에 미치는 영향에 대한 수리동역학적 2상-3차원 평가)

  • Yum, Kyung-Taek;Park, Hee-Kyung;Ahn, Je-Young
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.3
    • /
    • pp.219-231
    • /
    • 2004
  • The use of air diffuser system to ameliorate the reservoir by breaking stratification is now widespread. This study focuses on the hydrodynamic behavior of bubble plumes, which is the major mechanism of destratification and their combined effect of adjacent plumes on destratification efficiency. By introducing 2-phase Computational Fluid Dynamics(CFD) technique, we could suggest the optimal diffuser spacing having optimal destratification efficiency by simply analyzing the complex destratification procedures varying with the seasonal stratification intensity and bubble flow rate. Lab experiments were also carried out to verify CFD model in thermally stratified fresh water which quite differs from former researches using salts. This study showed that the mixing efficiency strongly depends on the spacing of neighboring plumes. When diffuser spacing is lower than 1.5 times the depth, the combined effect is stronger; as Plume Number(PN) is increased, the efficiency is strongly affected by spacing. If the distance is shorter than the depth of water, the efficiency increases linearly in proportion to PN. Otherwise, the efficiency increases non-linearly. These findings suggest that the combined effect should be more quantitatively taken into consideration for design and operation of air-diffuser destratification system, and recommend that the optimal destratification efficiency will be when plume number is 1000 and the spacing between neighboring diffusers is 1.5 times the depth.

Development of a DMFC-powered humanoid robot (직접 메탄올 연료전지를 이용한 휴머노이드 로봇의 전원시스템 개발)

  • Joh, Han-Ik;Ha, Tae-Jung;Cho, Jae-Hyung;Kim, Jong-Ho;Chae, Seung-Hoon;Whang, Sang-Youp;Moon, Sang-Heup;Ha, Heung-Yong;Cho, Baek-Kyu;Oh, Jun-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.332-335
    • /
    • 2006
  • 전극 전해질 복합체가 하나로 구성된 단위전지는 전기출력이 낮아 원하는 전기출력을 얻기 위하여 단위전지를 여러 장 직렬로 쌓아 스택을 구성하여야 한다. 본 연구에서는 400W급 직접메탄을 연료전지 스택을 제조하여, 운전 조건의 최적화를 위한 실험을 수행하였고, 한국형 휴머노이드 로봇인 Hubo에 적용하여 그 동특성을 평가하였다. 0.8M 메탄을 용액은 260 ml/min의 유량을, 공기는 42LPM을 스택에 주입하여 400W의 성능을 나타내었다. 연료전지 스택의 온도와 전압의 편차는 작았으며 정상 운전시스템의 온도는 약 $70^{\circ}C$를 유지하였다. 로봇의 필요 전력이 높을 경우, 배터리와 연료전지가 동시에 부하 변동에 대응하였다 방전된 배터리는 로봇의 필요 전력이 낮아질 경우, 충전되어 이후의 방전 상황에 대비하였다. 연료전지 시스템 적용 결과 로봇의 성공적인 운전을 확인할 수 있었다.

  • PDF

A Study on Production of Air Pollutants and Combustion Efficiency of Anthracite-Bituminous Coal Blend Combustor Using Fluidized Bed (유동층을 이용한 유,무연탄 혼합 연소로에서 대기오염물질 생성과 연소효율 연구)

  • Cho, Sang-Won;Min, Byoung-Chul
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.517-523
    • /
    • 1997
  • We have been studied that combustion efficiency and the production of air pollution of anthracite-bituminous coal blend in a fluidized bed coal combustor. Also, the reaching time of steady state condition have been studied. This experimental results are presented as follows. As the height of fluidized bed combustor becomes higher, the concentrations of $SO_2$ and NOx mainly increased. Also, as anthracite fraction increased, the emission of $SO_2$ concentration was increased but, the variation of $NO_X$ concentration was negligible according to anthracite fraction. When anthracite fraction ratio was increased, elutriation rate was increased and exit combustible content over feeding combustible content was increased. Regardless of anthracite fraction ratio the uncombustible weight percentage according to average diameter of elutriation particles were approximately high in the case of fine particles. Over bed temperature $850^{\circ}C$ and excess air 20%, the difference of combution at the velocity 0.3m/s, bed temperature $850^{\circ}C$, the excess air 20%.

  • PDF

Geomechanical Stability of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) using Coupled Thermal-Hydraulic-Mechanical Analysis (열-수리-역학적 연계해석을 이용한 복공식 지하 압축공기에너지 저장공동의 역학적 안정성 평가)

  • Kim, Hyung-Mok;Rutqvist, Jonny;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.394-405
    • /
    • 2011
  • In this paper, we applied coupled non-isothermal, multiphase fluid flow and geomechanical numerical modeling using TOUGH-FLAC coupled analysis to study the complex thermodynamic and geomechanical performance of underground lined rock caverns (LRC) for compressed air energy storage (CAES). Mechanical stress in concrete linings as well as pressure and temperature within a storage cavern were examined during initial and long-term operation of the storage cavern for CAES. Our geomechanical analysis showed that effective stresses could decrease due to air penetration pressure, and tangential tensile stress could develop in the linings as a result of the air pressure exerted on the inner surface of the lining, which would result in tensile fracturing. According to the simulation in which the tensile tangential stresses resulted in radial cracks, increment of linings' permeability and air leakage though the linings, tensile fracturing occurred at the top and at the side wall of the cavern, and the permeability could increase to $5.0{\times}10^{-13}m^2$ from initially prescribed $10{\times}10^{-20}m^2$. However, this air leakage was minor (about 0.02% of the daily air injection rate) and did not significantly impact the overall storage pressure that was kept constant thanks to sufficiently air tight surrounding rocks, which supports the validity of the concrete-lined underground caverns for CAES.

Effects of Operating Conditions on NOx Emission in OFA-type Boiler (OFA형 보일러의 운전조건이 NOx 발생에 미치는 영향)

  • Park, Kyoungwoo
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.253-259
    • /
    • 2013
  • In the present study, the characteristics of combustion phenomena and NOx emission in the OFA-type tangentially injected coal-fired boiler have been investigated numerically in order to find the effect of geometrical variation on the performance of the boiler. For these, numerical analyses of turbulent flow, chemical reaction, and radiation heat transfer are performed by using the computational fluid dynamics method. The predicted results clearly show that NOx formation highly depends on the combustion processes, the temperature and species concentrations. In addition, the optimum conditions for both the maximum NOx reduction and highest boiler efficiency can be obtained by considering the amount of supplied air and the injection angle at OFA, and modifying the boiler configuration. It is also found that the variation of supplied air at OFA is more effective than that of the injection angle for reducing the NOx emission, within the present operating conditions.

SCR facility design for the selective catalyst performance of mixed gas

  • Woohyeon, Hwang;Kyung-Ok, Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.1
    • /
    • pp.121-127
    • /
    • 2023
  • In this study, the design conditions and CFD analysis results are compared and reviewed in SCR that can optimally reduce nitrogen compounds. To this end, it was analyzed and compared using CFD to see if the design criteria were satisfied for the shell and tube areas of the boiler. In the SCR system, the analysis area is the gas/air heat exchanger on the shell side, and eight tubes of the gas/air heat exchanger on the tube side. Through CFD analysis, the gas velocity distribution on the primary catalyst side of the SCR system was designed to be 2.4%, and the NH3/NOx molar ratio distribution was 3.7%, which satisfied the design criteria. In addition, the uniformity of the temperature distribution was confirmed and the required condition of 260℃ or higher was satisfied. The angle of the gas entering the catalyst met the design conditions at 2.9 degrees, and the pressure loss that occurred also satisfied the design requirements. Through this CFD analysis, it was confirmed that it was designed and operated by satisfying the design conditions required for each area.