• Title/Summary/Keyword: 주위환경 열화

Search Result 13, Processing Time 0.024 seconds

Analysis of Properties according to Degradation in Transmission Line (송전선로의 열화에 따른 특성 분석)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.341-342
    • /
    • 2019
  • 송전선로에 널리 사용되고 있는 강심알루미늄연선(Aluminum Conductors Steel Reinforced, ACSR)은 스페이서와 같은 접속 부위에서 열화가 상당히 빠르게 진행된다. 그런데 현재와 같은 내용연한을 획일적으로 적용할 수 없기 때문에 설치된 송전선로의 주위 환경, 사용되는 부하 조건 등을 고려하여 합리적으로 송전선로를 운용하는 것이 필수적이므로 본 논문에서는 송전선로의 열화에 따른 특성 분석을 위한 연구를 수행하였다.

  • PDF

Evaluation on Termite Damage of the Traditional Wooden Building by Non-destructive Methods (비파괴 검사에 의한 전통목조건축물의 흰개미 열화 특성 조사)

  • Son, Dong-Won;Lee, Dong-heub
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.21-29
    • /
    • 2008
  • The deterioration of Korean traditional wooden house located in seoul was estimated. This house was attacked by termite. To estimate damage status of buildings, non-destructive methods were applied. Some of the post needed to be replaced due to low strength, estimated by nondestructive methods. The house was installed with boiler heating facility, to use office and public education. This kind of heating system changed the environmental condition of the wooden house. The termite which attacked the house was classified as Reticulitermes speratus. Because of durability of wooden house effected by environment, control of the environmental condition is essential for maintaining the wooden house. The installation of modern facility to traditional wooden house should not change the traditional structure and do not effect to durability of wooden house.

The aging characteristics of composite insulating materials due to high-temperature and high-moisture (고온 다습하에서 복합절연재료의 열화특성)

  • 이종호;이규철;김순태;박홍태
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 1994
  • For increasing the insulating proper-ties and the reliability of composite materials due to environmental aging, the electrical and mechanical characteristics of moisture absortion specimens and moisture desorption specimens were investigated. After moisture absorption wt% and moisture desorption wt% increased with time, a state of saturation arrived subsequent to a constant time. Moisture absorption constants with the layers of glass fiber showed 0.0117 in 1 layer, 0.0123 in 2 layers and 0.0152 in 3 layers. Electrical and mechanical characteristics dropped significantly with moisture absorbing in composite materials. Although moisture dried completly at 70.deg. C, it is impossible to obtain the electrical and mechanical characteristics before moisture absorption. Many defaults by moisture in composite materials exist at interface between epoxy matrix and filler.

  • PDF

HFPD Charasteristic Analysis of Power Transformer in Oxygen Plant (산소 공장 전력용 변압기에서의 HFPD 특성분석)

  • 유권종;김서영;김이곤
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.673-676
    • /
    • 2000
  • 변압기에서 발생되는 부분방전은 변압기의 운전중 절연열화에 대한 정보를 가장 잘 나타내고있으나, 현장에서 부분방전을 측정하는데 주변 환경적인 문제인 노이즈로 인해 측정의 어려움과 측정된 데이터의 정확한 판단에 어려움이 따른다. 이에 본 연구에서는 노이즈를 완전히 해결하지 못하는 기존방식을 벗어나 높은 영역에서 주위의 노이즈를 덜 받는 HFPD 측정법을 적용하여 광양제철 산소공장에서 데이터를 취득하여 부분방전을 분석하였다. 본 논문에서는 HFPD의 변압기적용과 강인한 현장환경에 따른 영향을 최소화하여 제안한 방법이 변압기의 부분방전 시험에 유용하게 사용할 수 있음을 보였다.

  • PDF

Development of Dissolved Gas Analysis/Diagnosis System with Transformer Fault Test Chamber (I) (변압기 내부 결함 모의시험장치를 통한 유중가스 분석/진단 시스템 개발(I))

  • Kim, Sung-Jik;Seo, Hwang-Dong;Kim, Young-Min;Jung, Jae-Ryong;Yang, Hang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1554-1555
    • /
    • 2011
  • 안정적인 전력공급을 위해 전력설비 진단이 중요시 되고 있고 이를 위해 변전기기인 변압기의 초기고장 검출을 통한 예방진단 기술을 필요로 하고 있다. 변압기 예방진단 기술 중에서도 유중가스진단은 가장 오래되고 신뢰성이 입증된 기술이다. 기존의 유중가스진단법들은 가스비분석법을 이용하고 있는데 대상 가스들이 절연유에의 열화에 의해 발생하는 가스들이고 주위 운전환경에 대한 고려가 부족하여 진단이 불가능하거나 진단오류가 발생한다. 본 연구에서는 절연유뿐만 아니라 고체절연물에 대한 열화를 고려하기 위하여 변압기 내부 결함 모의 시험 쳄버를 제작하고 시험 결과를 바탕으로 진단 알고리즘을 개발하고자 한다.

  • PDF

Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station (발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2017
  • The only method used in the power stations in order to deliver generated electric power is 6 kV XLPE (or CV) single core cables. Among many kinds of accidents happening in the power stations, the outbreak of fire due to the deterioration of live cables causes enormous socioeconomic losses. From the installation of the cables, the management and diagnose should be thoroughly made. Even though it differs depending on the installations and usage conditions, the cross-sectional area of cables is in shortage. The excessive allowable temperature caused from the current causes the deterioration of cables. In order to prevent an unexpected breakdown of live cables, we have invented a device to monitor and diagnose the status of cables. We have installed our device in the Korea Western Power Co., Ltd.. In this paper, we present our research results in situ that we have obtained by measuring the temperature of sheath, changing with the surrounding circumstances, especially ambient temperatures. We also show our study results of characteristics for temperature of sheath surface and load current at the ambient temperatures of $40^{\circ}C-10^{\circ}C$.

TTFF 감소를 위한 GPS 코드 기반의 개략 위치 추정 기법 설계

  • Yu, Won-Jae;Choe, Gwang-Ho;So, Hyeong-Min;Lee, Hyeong-Geun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.22-25
    • /
    • 2016
  • 해상에서의 선박 항해에 있어서 GPS와 같은 위성항법시스템에 대한 의존도가 매우 높다. 하지만 전파 교란 등과 같은 열악한 환경이 선박 주위에 가해질 경우 선박에 탑재된 GPS 수신기에서 위치를 추정할 수 없기 때문에 정상적인 항해가 어렵게 된다. 본 논문에서는 위와 같은 약한 전파 교란 환경을 가정하여 열악한 환경 내에서 GPS 수신기가 위치 추정 정확도는 열화되더라도 자신의 위치를 처음 파악하는 데 걸리는 시간인 TTFF(Time To First Fix)를 감소시켜 선박의 신속한 위치 계산을 위한 개략 위치 추정 기법을 설계하였다. 또한 열악한 신호 환경을 가정하여 진행된 실험에서 기존 GPS TTFF와의 비교를 통해 설계된 기법을 검증하였다.

  • PDF

Safety Analysis for Petrochemical Plant by Nondestructive Test (비파괴검사에 의한 석유화학설비의 안전진단)

  • 이주석
    • Journal of the KSME
    • /
    • v.34 no.11
    • /
    • pp.859-866
    • /
    • 1994
  • 석유화학플랜트에서 운용되는 반응로, 저장탱크, 열교환기 등의 압력용기 그리고 배관 등의 시 설물은 장기간 사용함에 따라 고온, 고압, 부식성 분위기, 열응력, 피로 등 여러 가지 요인으로 경년열화되어 노후화 된다. 일반적으로 이들 설비들에서 작용하는 유체나 가스의 누출은 화재나 폭발과 같은 재해 뿐만아니라 주위 환경을 오염시켜 공해를 유발하게 되며, 이들 시설물에 대한 신뢰성 및 안전성 확보는 국가기간 산업에서 매우 중요하며 이와 관련된 장치의 설계, 시공 뿐만 아니라 시험검사 및 평가기술 측면에서도 중요시되고 있다. 플랜트 시설물에 대한 가동중 주기적인 안전진단은 현상의 파악 뿐만 아니라 인명과 재산의 손실을 미연에 예방하고 경제적 이고 효율적인 운영계획 수립에 필수적인 것이다. 이 글에서는 국내 석유화학플랜트의 검사현 황을 알아보고 앞으로 플랜트의 효율적 운영 및 안전 운전을 위한 가동중검사 기술 및 개선대 책에 대하여 기술하고자 한다.

  • PDF

Reliability Evaluation through Failure Analysis and Degradation Characteristics of Ag External Electrodes. (Ag 외부전극재의 열화특성 및 고장해석을 통한신뢰성평가)

  • 김은미;박영식;이의종;김용남;최덕균;송준광;이희수
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.227-227
    • /
    • 2003
  • 캐패시터, 인덕터 등의 전자부품들은 적층기술 및 표면 실장 기술 등을 이용하여 적층형 칩형태로 제작되고 있다. 적층형 칩형태의 전자부품들은 전자기적 특성을 부여하는 세라믹스와 전극역할을 하는 금속으로 구성되어 있으며, 전극 부분은 크게 내부전극과 외부전극으로 구분된다. 고장이 발생하게 되면 고장의 형태를 의미하는 고장모드(failure mode)와 제품을 고장에 이르게하는 물리, 화학적, 기계적 과정을 의미하는 고장기구(failure mechanism)을 조사하게 된다. 전자부품에서 고장이 발생하였을 경우, 1차적인 분석대상은 전극재인데 전극재에 기인한 고장으로는 세라믹스와 전극재 사이의 열팽창계수 차이에 기인한 박리현상(Delamination), 인쇄불량에 의한 단락 및 두께 불량, 세라믹스와 전극재 사이의 반응, 산화에 의한 부식 등이 있다. 이러한 고장은 급격한 주위 환경의 변화에 의한 것보다는 일정수준의 스트레스가 축적되어 발생하며, 수명을 예측하기 위해서는 고장의 원인을 규명하고 그 원인에 의한 가속 시험을 수행하는 것이 일반적인 방법이다. 본 연구에서는 Ag 외부 전극재의 수명을 예측하고자 가속시험을 수행하였고, 고장 분석 통하여 Ag외부 전극재의 특성 및 문제점 등을 정확히 파악하기 위한 연구를 하였다.

  • PDF

The effect of air quality and humidity on aged characteristics of beeswax-treated paper during artificial aging (인공열화 시 공기질 및 습도가 밀랍지의 열화에 미치는 영향)

  • Yang, Eun Jeong;Choi, Kyoung Hwa;Kang, Yeong Seok;Cho, Jung hye;Jeong, Hye Young
    • 보존과학연구
    • /
    • s.33
    • /
    • pp.45-55
    • /
    • 2012
  • A beeswax-treated paper has no air permeability but has the water repellency compared with a general Hanji. Because of these properties, the differences of the aging factors and mechanisms between the outer partition of beeswax-treated paper that is affected by the surrounding conservation environment and the inner partition of it that is not affected are bigger than general books. In this research, we analyzed and compared the aging characteristics through the accelerated aging of the beeswax-treated paper by some air and humidity conditions. The results of the physical and optical analysis after the artificial aging, it was shown that the oxygen accelerates the aging of the beeswax-treated paper and the condition with the humidity 50% RH is more stable than the condition with the humidity 0% RH. The results of the CG/MS analysis that was conducted to figure out the decomposition charateristics of the beeswax according to the air quality and the humidity, a low molecular weight compound that the number of carbon is C9-C20 including a fatty acid such as a palmitic acid was increased as the aging was progressed. However, under the same environment, a compound that the number of carbon is C21-C36 including a hydrocarbon and a aliphatic alcohol and a high molecular weight compound that the number of carbon is more than C34 including a wax ester were decreased. A rate of change according to the air quality and the humidity was similar to the beeswax-treated papers.

  • PDF