• Title/Summary/Keyword: 주요 손상

Search Result 2,406, Processing Time 0.034 seconds

Analysis and Prediction of Highway Bridge Deck Slab Deterioration (고속도로 교량 바닥판 열화분석 및 추정)

  • Lee, Il-Keun;Kim, Woo-Seok;Kang, Hyeong-Taek;Seo, Jung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.68-75
    • /
    • 2015
  • This study established key factors causing deck slab deterioration based on GPR database of 747 highway bridges, and predicted deck slab damage rates with respect to bridge service life. To minimize the influence of bridge service life on deck slab deterioration, the deck slab damage rate database was corrected based on a linear regression model of bridge service life vs. deck slab damage rate. The corrected deck slab damage rates were analyzed to determine correlation considering the number of snowy days, the amount of snowfalls, the number of freeze-thaw days, average winter temperature, altitude, the amount of deicing chemicals and equivalent traffic volume, and then both the number of freeze-thaw days and the amount of deicing chemicals were determined to be key factors causing deck slab deterioration. The complex deterioration considering both key factors was represented deck slab damage rate charts, and the average deck slab life was derived. The results of this study will be used as a guideline for highway bridge maintenance to identify the progress of deck slab deterioration for a given bridge and predict the time required deck slab rehabilitation.

Nonthermal Sterilization of Pathogenic Escherichia coli by Intense Pulsed Light Using a Batch System (회분식 광펄스 처리에 의한 병원성 대장균의 비가열 살균)

  • Kim, Ae-Jin;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • Intense pulsed light (IPL), a nonthermal technology, has attracted increasing interest as a food processing technology. However, its efficacy in inactivating microorganisms has not been evaluated thoroughly. In this study, we investigated the influence of IPL treatment on the inactivation of Escherichia coli O157:H7 depending on light intensity, treatment time, and pulse number. Increased light intensity from 500 V to 1,000 V, raised the inactivation rate at room temperature. At 1000 V, the cell numbers were reduced by 7.1 log cycles within 120 s. In addition, increased pulse number or decreased distance between the light source and sample surface also led to an increase in the inactivation rate. IPL exposure caused a significant increase in the absorption at 260 nm of the suspending agent used in our experiments. This indicates that IPL-treated cells were damaged, consequently releasing intracellular materials. The growth of IPL-irradiated cells were delayed by about 5 h. The degree of damage to the cells after IPL treatment was confimed by transmission electron microscopy.

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF

Podocytopathy and Morphologic Changes in Focal Segmental Glomerulosclerosis (초점분절사구체경화증에서 발세포병증과 형태 변화)

  • Jeong, Hyeon Joo
    • Childhood Kidney Diseases
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2013
  • Podocytopathy is glomerular lesions characterized by podocyte injury. It is observed in various glomerular diseases, but minimal change disease and focal segmental glomerulosclerosis (FSGS) are the prototypes. In this review, morphologic features of podocyte injury and subtypes of FSGS will be reviewed briefly. Effacement of podocyte foot processes is the most common feature of podocyte injury. As podocytic injury progresses, intracytoplasmic vacuoles, subpodocytic cyst, detachment of podocytes from the glomerular basement membrane and apoptosis develop. Glomerular capillary loops in epithelium-denuded area undergo capillary collapse. Synechia and hyalinosis may accompany this lesion. To manifest segmental sclerosis, podocyte loss above a threshold level may be required. Injured podocytes can injure neighboring intact podocytes, and thereby spread injury within the same lobule. FSGS can be categorized into five subtypes by morphologic characteristics; not otherwise specified (NOS), perihilar, cellular, tip, and collapsing types. Each subtype has been reported to show different clinical courses and associated conditions, but there are controversies on its significance. With recent progress in the discovery of genetic abnormalities causing FSGS and plasma permeability factors, we expect to unravel pathophysiology of FSGS and to understand histological sequences leading to FSGS in near future.

Study on Creep Damage Model of 1Cr1Mo1/4V Steel for Turbine Rotor (1Cr1Mo1/4V 터빈 로터강의 크리프 손상 모델에 관한 연구)

  • Choi, Woo-Sung;Fleury, Eric;Song, Gee-Wook;Kim, Bum-Shin;Chang, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.447-452
    • /
    • 2011
  • It is well known that the dominant damage mechanisms in high-temperature steam turbine facilities such as rotor and casing are creep and fatigue damages. Even though coupling of creep and fatigue should be considered while predicting the life of turbine facilities, the remaining life of large steam turbine facilities is generally determined on the basis of creep damage because the turbines must generate stable base-load power and because they are operated at a high temperature and pressure for a long time. Almost every large steam turbine in Korea has been operated for more than 20 years and is made of steel containing various amounts of principal alloying elements nickel, chromium, molybdenum, and vanadium. In this study, creep damage model of 1Cr1Mo1/4V steel for turbine rotor is proposed and that can assess the high temperature creep life of large steam turbine facilities is proposed.

Damage Diagnosis of Drill Bit while Drilling using Wavelet Transform Analysis (웨이블릿 변환 분석을 이용한 천공 중 드릴 비트의 손상 진단)

  • Jang, Hyongdoo
    • Explosives and Blasting
    • /
    • v.38 no.1
    • /
    • pp.14-22
    • /
    • 2020
  • Bit damage is one of the primary causes of decreasing drilling efficacy. Nevertheless the management of bit ware and failure are often left for field engineers' experience. Thus it is imperative to establish a proper system to predict and manage the bit damage during the rock drilling process. In this study, the drilling sound signal has been recorded and analyzed using wavelet transform analysis to identify the exact moment of bit failure. Through the analysis wavelet time-frequency spectrums have been constructed and an abnormal point has been identified with 0.9 of wavelet transform value at the 652.8s on a frequency band around 500Hz. Furthermore it is also observed that the penetration rate of the damaged bit has been decreased to 23mm/s which is 9mm/sec lower than the average of undamaged bit. The study verifies that wavelet transform analysis can be used to build a system to diagnose the bit damage while drilling.

Structural Restoration for the Electric Power Transmission Tower Damaged by Foundation Settlements (기초침하에 의해 손상된 송전철탑 구조물의 구조성능개선)

  • Lee, Ho Beom;Park, Jong Kwon;Kim, Il Soo;Jang, Il Young;Song, Jae Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.83-93
    • /
    • 2013
  • Generally the capacities of electric power transmission tower's members are improved by increasing their stiffness nature through injection of grout or attachment of other structural stiffeners. Those are for upgrading their axial strength by fulfillment of proper materials into pipe members, increment of member dimension by addition of section, or a combination of the two. However the use of innovative and unusual procedures would be positively recommended for getting more stable state. It is that buckled members are replaced with lengthened and strengthened members. In providing the structural restoration procedures for the existing electric power transform tower whose main members have been damaged due to unequal foundation settlement, structural damage inspection works and numerical analyses for the damaged one and the restored one were done in detail at first. secondarily member-exchanging works using a newly-generated jacking system and strengthened members were achieved. This figures are to point clearly to inherent advantages attending the management of the towers.

Research on Advanced Methods for Data Extraction from Corrupted OOXML Files (손상된 OOXML 파일에서의 데이터 추출 고도화 방안 연구)

  • Jiyun Kim;Minsoo Kim;Woobeen Park;Doowon Jeong
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.34 no.2
    • /
    • pp.193-206
    • /
    • 2024
  • In tandem with the advancements in the digital era, the significance of digital data has escalated, necessitating an increased focus on digital forensics investigations. However, the process of collecting and analyzing digital evidence faces significant challenges, such as the unidentifiability of damaged files due to issues like media corruption and anti-forensic techniques. Moreover, the technological limitations of existing tools hinder the recovery of damaged files, posing difficulties in the evidence collection process. This paper aims to propose solutions for the recovery of corrupted MS Office files commonly used in digital data creation. To achieve this, we analyze the structure of MS Office files in the OOXML format and present a novel approach to overcome the limitations of current recovery tools. Through these efforts, we aim to contribute to enhancing the quality of evidence collection in the field of digital forensics by efficiently recovering and identifying damaged data.

A Study on the Reinforcement Performance of Carbon Fiber Plate(CFP) for Demaged Reinforced Concrete Beam (손상된 철근콘크리트보에 있어서 탄소섬유판의 보강 성능에 관한 연구)

  • Kim, Cheol-Hwan;Ham, Young-Duck;Kim, Ku-Jin
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.3 s.17
    • /
    • pp.109-115
    • /
    • 2005
  • The experimental work was performed to investigate the effect influenced to the hystresis and the flexural strength improvement of RC beam using carbon fiber plates. Major parameters of this experimental program were the section size of carbon fiber plates and the damage level of RC beam before reinforcement. Particularly, the damage level of beam is for the cases damaged by overloads. The damage level is for 30%, 60%, and 100% of flexural strength, and no damaged beams were also tested for comparison with the damaged one. from the test results, it showed that the beams reinforced by carbon fiber plates had the higher strength and lower deformation capacity than the general beams and that it had the same ductility ratio of the general beams.

  • PDF

Damages of Chuteway Slabs of Spillway by Water Release (수문방류에 따른 여수로 바닥슬래브의 손상 발생)

  • Shin, Dong-Hoon;Jung, Woo-Sung;Yoo, Hyung Ju;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.64-64
    • /
    • 2021
  • 댐의 중요 구성요소 중 하나인 여수로 구조물은 관행적으로 단위길이당 100m3/s 정도의 유량이 흐를 수 있도록 설계를 하고, 이를 초과할 때는 여수로 구조물에 피해가 가지 않도록 공기혼입 장치를 설치하거나 콘크리트의 설계강도를 증가시키는 대책을 사용하는 것이 일반적이다(댐설계 기준·해설, 2011) 그러나 건설된 지 오래된 댐의 경우 여수로 콘크리트 구조물의 설계강도가 낮고(최저 16.7MPa) 수문방류 횟수가 많아 최근에 건설된 댐 여수로 보다 상대적으로 많은 손상이 발생되어 있어 잦은 보수보강이 요구되고, 점차 유지관리 비용이 증대되고 있어 노후된 여수로 구조물일수록 기능을 유지하면서도 유지관리 비용을 절감할 수 있는 방안의 수립이 요구되고 있다. 이에 본 연구에서는 𐩒𐩒𐩒댐 여수로를 대상으로 2020년 홍수기 전·후의 여수로 바닥슬래브의 손상상태를 3D드론 매핑, 육안조사 및 내구성 조사결과 등을 이용한 정밀분석을 통해 수문방류시 여수로 바닥슬래브에 가장 큰 손상을 일으키는 손상메커니즘으로 유수에 의한 부상(uplift)에 의한 파손 메커니즘(Flow-driven uplift failure mechanism)을 제시하였으며, 여수로 바닥슬래브의 가장 일반적 손상원인으로 간주되고 있는 공동현상(cavitation)이 공동지수(cavitation index)가 0.3이상인 경우에도 발생할 수 있음을 확인하였다. 이와 같은 관찰 및 분석결과는 보다 많은 사례를 통하여 보완될 경우 향후 여수로 구조물의 설계 뿐만 아니라 보수보강 방법이나 유지관리, 더나아가서는 종합적 댐시설물 자산관리 계획을 수립하는데 매우 유용한 자산이 될 수 있다.

  • PDF