• Title/Summary/Keyword: 주사기

Search Result 1,122, Processing Time 0.027 seconds

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.

Receiver-Centric Spectrum Sensing for Cognitive Radio Systems (무선인지 시스템을 위한 수신기 중심 스펙트럼 센싱 기술)

  • Shin, Oh-Soon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.2
    • /
    • pp.43-48
    • /
    • 2011
  • Cognitive radio is accepted as an effective and promising approach for resolving the spectrum scarcity problem by allowing secondary users to borrow unused spectrum from primary users. A method of identifying busy and empty spectrum at the given time and space, which is called spectrum sensing, constitutes an essential element of the cognitive radio. In this paper, we propose a receiver-centric spectrum sensing scheme which attempts to detect the primary receiver rather than the primary transmitter. It is shown that the proposed receiver-centric sensing approach results in more efficient spectrum utilization than the conventional transmitter-centric sensing.

Analysis of Frequency Response of Piezo Stages and Scanning Path Monitoring/Compensation for Scanning Laser Optical Tweezers (주사 레이저 광집게를 위한 압전 구동기 주파수 특성 분석과 주사 경로 추적 및 보상)

  • Hwang, Sun-Uk;Lee, Song-Woo;Lee, Yong-Gu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.132-139
    • /
    • 2008
  • In scanning laser optical tweezers, high speed scanning stages are used to manipulate a laser beam spot. Due to the inertia of the stage, the output scanning signal decreases with increased frequency of the input signal. This discrepancy in the signals is difficult to observe since most of the energy from the laser beam is blocked out to avoid CCD damage. In this paper, we propose two methods to alleviate these problems. Firstly, frequency responses of piezo stages are measured to analyze the signal drops and the input signal is compensated accordingly. Secondly, an overlay of the scanning path is drawn on the live monitoring screen to enhance the visibility of the scanning path. The result is a drop-compensated scanning with clear path view.

Spatio-Temporal Video De-interlacing Algorithm Based on MAP Estimation (MAP 예측기 기반의 시공간 동영상 순차주사화 알고리즘)

  • Lee, Ho-Taek;Song, Byung-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.69-75
    • /
    • 2012
  • This paper presents a novel de-interlacing algorithm that can make up motion compensation errors by using maximum a posteriori (MAP) estimator. First, a proper registration is performed between a current field and its adjacent fields, and the progressive frame corresponding to the current field is found via MAP estimator based on the computed registration information. Here, in order to obtain a stable solution, well-known bilateral total variation (BTV)-based regularization is employed. Next, so-called feathering artifacts are detected on a block basis effectively. So, edge-directional interpolation is applied to the pixels where feathering artifact may happen, instead of the above-mentioned temporal de-interlacing. Experimental results show that the PSNR of the proposed algorithm is on average 4dB higher than that of previous studies and provides the better subjective quality than the previous works.

그람 양성균 감염증에서 Vancomycin 과 Teicoplanin 의 임상효과의 비교 연구

  • 최강원;오명돈;배현주
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.331-331
    • /
    • 1994
  • 최근 개발된 Teicoplanin은 glycopeptide계의 항생제로서 vancomycin과 그 작용 기전이 비슷하지만, 근육 주사가 가능하고, 반감기가 길어서 하루 한번 주사하여도 되며, 빨리 주입하더라도 red man syndrome이생기지 않는 장점이 있다. 이 연구의 목적은 그람 양성균에 의한 감염증을 치료하는데 teicoplanin이 효과적이고 안전한지를 vancomycin과 비교하는 것이다. 대상 환자 및 방법: 서울대학교병원에 입원하여 그람 양성균 감염증이 확인되거나 강력히 의심되는 환자를 대상으로 하였다. 감염증의 종류는 패혈증, 골수염, 하기도 감염증, 감염성 관절염, 피부 및 연조직 감염증, 요로 감염증으로 하였다. 대상 환자를 무작위로 teicoplanin또는 vancomycin군에 무작위 배정하였다. Teinoplanin은 처음에 loading을 위하여 400mg씩 12시간마다 3회 주사하고 이후에는 증증 감염이면 하루에 400mg, 중등중이면 200mg씩을 주사하였다. Vancomycin은 500mg을 6시간마다 또는 1. 0g을 12시간마다 정맥주사하였다. 치료 기간은 요로 감염증 5-10일, 하기도 감염증 5-10일, 패혈증 14-21일, 골수염 21-42일, 세균성 관절염 21-42일, 피부 및 연조직 감염증 5-10일로 하였다.

  • PDF

주사형 정전용량 현미경(SCaM)의 개발

  • 김응규
    • 전기의세계
    • /
    • v.42 no.9
    • /
    • pp.6-11
    • /
    • 1993
  • 미소탐침을 STM과 같이 PZT등의 압전액튜에이터로 대상물을 2차원 또는 2.5차원 주사해서 그 정전량을 화상화하는 주사형 정전용량 현미경(SCaM)의 개발에 대해서 기술했다. 광학현미경과 레이저현미경은 빛을 이용하기 때문에 파장의 제약을 받아 그 분해능의 한계는 0.3[.nu.m]정도이다. 이것에 대해 SCaM은 광학방식가 같은 분해능의 원리적 한계가 없고, 또한 광학상과는 다른 유전율상의 특성화상이 얻어진다. 이와같은 특징에 의해, 최종적으로 0.01[.mu.m]레벨의 분해능을 얻을 수 있는 실용레벨의 현미경을 시험제작함을 목적으로 하고 있다. 본 연구에서는 탐침과 시료표면간의 거리를 진동에 의해 미소로 변화시켰을 때의 정전용량의 변화를 포착하는 미분용량법을 이용했으며, 탐침높이 및 주사시에 있어서의 검출기 출력의 재현성, 즉 신호 검출방식으로서의 S/N이 양호한 동기검파를 이용했을 대해서 실험적 검토를 하였다. 이와같은 검파방식에 의해 잡음, 히스테리시스 등의 영향에 대해 개선이 되고, 분해능도 향상되었다. 더욱이 2.5차원 탐침 주사방식 미분용량형 정전용량 현미경에 의해 칼날 부분 선단부의 확대화상이 명료하게 얻어졌다. 그러나 실용적으로는 아직 불충분하다.

  • PDF

글루코스 옥시다제가 고정화된 Composite Poly(vinyl Alcohol)/Chitosan Blend막을 통한 약물의 방출조절

  • 김진홍;이영무
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.04a
    • /
    • pp.56-57
    • /
    • 1992
  • 만성대사 질환인 당뇨병 치료제로서 인슐린은 가장 널리 상용되는 약가운데 한가지 이다. 그러나 인슐린은 생물학적 반감기가 매우 짧아서 효과적으로 투여하기가 매우 어려워 현재까지 주사를 이용하여 투여하고 있으며 이에 따른 환자의 고통, 주사에 따른 불편함 및 과량의 인슐린이 투여 될 경우에 생기는 저혈당증등 여러가지 부작용을 수반하게 된다.

  • PDF

2001 AIDS (2001년과 에이즈 - 국내 -)

  • 대한에이즈예방협회
    • RED RIBBON
    • /
    • s.43
    • /
    • pp.28-29
    • /
    • 2001
  • 실제 감염인은 2명 이상임을 의미하고 마약사용자들간에도 상당수의 감염인이 있을 수 있음을 의미한다. 이는 과거에 비해 에이즈가 전파될 수 있는 감염경로는 훨씬 다양해졌음을 의미한다. 즉 마약사용 주사기뿐만 아니라 인터넷을 통한 번개섹스, 청소년 매매춘(원조교제), 노래방, 증기탕 등을 통한 주부매춘, 노인 매매춘 등으로 감염경로가 넓어졌다.

  • PDF

일부 주사기 제조업과 병원 종사자의 에틸렌옥사이드 노출수준 비교

  • An, Seon-Hui;Sin, Jeong-A;Kim, Gang-Yun;Choe, Ho-Chun
    • 월간산업보건
    • /
    • s.186
    • /
    • pp.27-35
    • /
    • 2003
  • 본 분석기법은 유해인자별 작업환경측정 및 특수건강진단 시료를 분석할 때 간편하게 활용할수 있는 방법으로 산업보건관련 유관기관에 실질적인 도움을 주고자 합니다. 이 분석기법들 중에는 공식적으로 검증, 채택되지 아니한 기법이 있음을 알립니다.

  • PDF

난황형성기 모체내 3,5,3'-triiodo-L-thyronine ($T_{3}$) 주사에 의한 조피볼락 자치어의 성장과 생존율 향상

  • 강덕영
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 1998.07a
    • /
    • pp.66-67
    • /
    • 1998
  • 난황형성기의 난소를 가진 암컷 어미에게 갑상선 호르몬인 3,5,3'-triiodo-L-thyronine ($T_{3}$)를 20 mg $T_{3}$/kg체중으로 주사하여 출산된 조피볼락 자어를 대조구 자어와 함께 30일간 사육하면서 성장과 생존율을 비교하였고, 실험종료시인 전어체를 갈아 체성분 조성을 파악하였다. 출산자어의 성장은 대조구에 비해 $T_{3}$구에서 유의하게 빨랐으며, 생존율 역시 $T_{3}$구가 대조구보다 유의하게 높았다. 실험종료시 치어의 비만도는 대조구가 $T_{3}$구에 비해 높게 나타났다. 실험종료시 $T_{3}$구의 어체내 수분과 회분함량은 대조구의 결과와 유의한 차이를 보이지 않았으나, 단백질 함량은 $T_{3}$구에서 대조구 보다 높았으며, 지질은 $T_{3}$에서 오히려 낮았다. 이상의 결과로 조피볼락에 대한 $T_{3}$의 모체주사는 출산자어의 성장과 생존율 향상에 도움을 주는 것으로 평가되었다.

  • PDF