A Study on the Improvement Plan for the Practical Use of Inner and Outer-Temporary Housing (실내·외 임시주거시설의 실용성 향상을 위한 개선방안에 관한 연구)

  • Seo, Boongkyo;Yeom, Taejun
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.409-420
    • /
    • 2018
  • Purpose: The purpose of this study is to present improvement measures for enhancing practicality through case analysis of Inner and Outer-Temporary Housing. Method: First, the basic functions and types of Temporary Housing, were discussed through prior research analysis. Second, a practicality problem was derived by analyzing cases of Temporary Housing. Third, improvement measures were proposed to ensure the practicality of Temporary Housing based on the problems identified. Results: Factors such as habitability, economics, construct ability and operation methods that should ultimately be improved in Temporary Housing, and these elements were divided into production, transportation, construction, and storage according to the life cycle, suggesting matters to be improved in order to improve practicality at each stage. Conclusion: The proposed improvements are considered to help develop inner and outer-temporary housing.

A Study on the Analysis of Environment Performances in High-Rise Residential Building Through Green Building Certification System (친환경건축물 인증제도 평가를 통한 고층 주거용 건물의 환경성능 분석)

  • Chae, Mun-Byoung;Cha, Min-Chul;Jae, Seong-Ho;Seok, Ho-Tae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.281-286
    • /
    • 2006
  • In case of Korea, immovable property like location, land prise or investment value is more highly estimated than quality of life of residents for performance and value of apartment house, because of limited land area or high density of population. But the high level of life has recently caused the increasing demand in better life. As there is no cases to provide the house in bulk due to the housing market condition, it is necessary to evaluate performance and value of structure, disaster prevention safety, habitability, antiquated condition of building and equipment, maintenance condition and so on that has importantly influence on resident's life quality. So, this study aims to understand the actual condition of environmental performance for the present apartment by comparing the designated apartment, which is ready to have completed in Daegu, with the mixed use residential building, which gained the best grade for green building certification system. Also by analyzing and evaluating a right to enjoy sunshine, floor impact noise etc. and indoor air quality.

  • PDF

A Numerical Analysis for Fire Spread Mechanism of Residential Building Fire (주거용 건축물의 화염전파 현상에 대한 수치해석적 검토)

  • Ahn, Chan-Sol;Kim, Heung-Youl;You, Yong-Ho;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • This study is intended to present a computational thermal model for a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the fire properties of a residential fire, we made some numerical models of combustibles and residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator (FDS) was used with Large Eddy Simulation (LES) model for turbulence. Consequently, fire-intensity was well predicted and flash-over of rooms were successfully estimated.

A Study on the Evaluation Indicators of Healthy Housing Quality of Multi-Family Housing (공동주택의 건강성능 평가지표 개발에 관한 연구)

  • Cho, Sung-Heui;Kang, Na-Na
    • Journal of the Korean housing association
    • /
    • v.22 no.1
    • /
    • pp.43-55
    • /
    • 2011
  • The purpose this study is to develop indicators that measure the healthy housing condition of multi-family housing. The major findings are as follow: first, healthy housing was defined by physical, mental, social, and management aspects and proposed the conceptual model of hierarchy structure of evaluation of healthy housing by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about both domestic and overseas multi-family housing. The evaluating indicators were identified as a total of 87 evaluating items which were composed of four dimensions and 16 attributes on the basis of the conceptual model. They cover comprehensive scope of the multi-family housing such as unit, building, complex, and site. Third, as the measurement, the 5-point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was developed by AHP method conducted by survey of an expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The level of healthy housing condition may be evaluated by both total evaluation and a specific field of evaluation.

A Study on the Ventilation Performance Estimation of Marketing Ventilation Fan Used in the Apartment House Kitchen (공동주택의 주방에서 사용되는 시판 환풍기의 환기 성능 평가에 관한 연구)

  • 송필동;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.315-320
    • /
    • 2002
  • Marketing ventilation fan 3 kinds been using in kitchen of apartment house into compensation discharge performance of contaminant measure. When propane gas burns by gas table, did waste heat into measurement compensation with carbon dioxide that it happens. In measured all type of exhaust fan, discharge performance of carbon dioxide and waste heat was high there are been much displacement. Among A, B, C three types, performance of A type exhaust fan was most superior and performance of C type exhaust fan was most poor

  • PDF

A Time series Analysis on the Performance Items of the "Housing Performance Grading Indication System" (주택성능등급표시제도 성능항목의 특성 및 시계열분석( I ))

  • Lee, Sung-Ok;Kim, Soo-Am;Shin, Sung-Eun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.213-216
    • /
    • 2009
  • The purpose of this study is analyzing temporal flow about 20 detailed performance items in the "Housing Performance Grading Indication System". This study try to figure out situations according grade in detailed performance item and to analyze change item about 112 cases(2 cases in 2006, 15 cases in 2007, 46 cases in 2008, 49 cases in 2009), from January 9, 2006 which system is undertaken, to October, 2009. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control & ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). Total efficiency about housing can understand systematically of 20 perfomance items though this research.

  • PDF

A Case Study on the Evaluation of Residential Performance for Deteriorated Multi-family Housing (노후공동주택의 거주성능 평가에 관한 사례 연구)

  • Hyun Taek-Soo;Lee Byung-Tae
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.77-85
    • /
    • 2006
  • This study aims to propose the comprehensive evaluation of performance multi-family housing. Most of the existing studies for the reproduction have evaluated by the safety of structure. Therefore those pass over the functional factors which is important for the evaluation of residential qualities. This study represents that the reproduction renovation should not be secured the safety of structure but established the quality of lift. And questionnaire asking expert's opinion also supplemented. As a result, the item for examination and the weight for evaluation are suggested in functional deterioration. The results of this study are summarized as follows: 1. Existent redevelopment criteria are not appropriate to decide the environmental comfort, the vital function of housing and the residential management finance. 2. The future criteria have to evaluate the existing environmental comfort, be reconstructed to put first general deterioration. 3. Evaluation elements was extracted throughout the document research, evaluation elements analysis system was separated in residential area, suburb of dwellings, community, and housing complexity environmental assesment, 4. Each category of influence ratio was extracted to assess total deterioration throughout the expert question survey. 5. Each category analysed (1) $0{\sim}30%$: function is good (unnecessary to improve) (2) $31{\sim}40%$: average (necessary of partial improvement) (3) $41{\sim}59%$: bad (necessary of total improvement) (4) $60{\sim}100%$: the worst (unable to improve throughout the repair)

Application Experiment of Mirror Sunlighting System to House (반사거울형 태양광채광시스템의 주택적용 실험)

  • Jeong, In-Young;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.57-60
    • /
    • 2005
  • 자연채광은 실내공간의 쾌적성을 향상시키며, 재실자의 건강을 증진시킬 뿐만 아니라 에너지 절약적인 측면에서 시너지 효과를 발휘하고 있다. 이에 반사거울형 태양광채광시스템은 도시가 과밀하고 고층화됨에 따라 자연채광의 도입이 어려운 실내공간에 태양광을 도입할 수 있는 자연에너지 활용장치라 할 수 있다. 본 연구는 태양광채광시스템을 이용하여 주거건물 옥상에 1차반사거울을 설치하고, 반지하의 상부에 2차반사거울을 설치하여 거실공간에 태양광을 유입하였다. 시스템 미설치시와 설치시에 대한 거실의 바닥면조도와 외부조도를 동시에 측정하여 외부조도에 대한 내부조도의 비율인 주광조도비를 분석하고, 증감율을 구하여 반사거울형 태양광채광시스템의 성능을 평가하였다. 채광성능평가 결과 채광시스템의 설치로 인한 실내 주광조도비는 평균 $80{\sim}1,400%$정도 증가하는 것으로 나타났으며, 또한 창면부에 비해 실의 후면부가 2배 이상 증가한 것으로 나타나 채광성능이 매우 큰 것으로 나타났다. 따라서 본 연구에서 실험한 반사거울형 태양광 채광시스템은 주거건물에서의 적용이 용이하고 높은 채광성능을 제공할 수 있어 실내 빛환경 향상에 크게 기여할 수 있을 것으로 기대된다.

  • PDF

Exploratory approach to measuring facility performance in public service facilities (공공서비스시설에서의 시설성능 요인에 대한 탐색적 연구)

  • Lee, So-Young;Shin, Hee-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.284-287
    • /
    • 2009
  • In order to plan and manage public facilities effectively and efficiently, it is necessary to diagnose the current status of facilities and decide the objective features. Performance measurement is to provide managers with the information they need to measure competitive advantages. This paper discusses public facility performance in order to establish the conceptual framework for performance measurement for public facilities. In order to develop the measurement of public facility performance, a pilot study was conducted with facilities managers of facilities management corporation of public districts in Seoul. We investigated how public facilities management teams have assessed their performance and collected data regarding financial aspects, service aspects, community aspects, and building aspects. There is no standard format to measure facility performance since building sizes, programs, community needs widely differ. However, it is necessary to have a more consistent system to measure facility performance. In addition, each public municipal district needs to empower each district facilities management corporation to participate in managerial decisions and budget control.

  • PDF