• Title/Summary/Keyword: 조한구

Search Result 232, Processing Time 0.029 seconds

Analysis of Sheath Induced Voltage and CCPU Operating Characteristic in Underground Transmission Cable (지중송전계통에서 시스유기전압 및 CCPU 동작 특성 해석)

  • Jin, Hye-Young;Lee, Jong-Beom;Kim, Young;Cho, Han-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.494-496
    • /
    • 2001
  • This paper describes sheath induced voltage and operating characteristic of cable cover protection unit(CCPU) in underground transmission cable. Real cable system operating by 154kV XLPE cable was modelled for simulation. Sheath induced voltage and operating characteristic of CCPU were analyzed. In particular, sheath induced voltage was analyzed in case of individual grounding and common grounding, respectively, and operating characteristics of CCPU were compared each other.

  • PDF

Surface Characteristics of Silicone Rubber Processes by Corona Discharges (코로나 방전에 따른 실리콘 고무의 표면 특성)

  • 한동희;조한구;강동필;민경은
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.133-140
    • /
    • 2002
  • This paper aims to investigate the effect of silicone oils as processing agent affecting the loss and recovery of hydrophobicity. The recovery of hydrophobicity was evaluated by the measurement of the surface electrical resistivity and the contact angle on the SIR surface. Two kinds of silicone oils (1 and 2) having different molecular weight were selected under a consideration of hydrophobicity and processability. SIR specimens were exposed to corona discharges in air and the specimens were analyzed with contact angle and surface resistance measurements. It was observed that the contact angle and the surface resistivity of SIR increase gradually with testing time. The fast recovery of hydrophobicity of SIR, expressed by the increment of contact angle and surface resistivity, was showed in SIR2 containing silicone oil 2.

Protection of Insulation Joint Box and Analysis of Overvoltage in Underground Power Cable Systems (지중송전케이블계통에서 절연통 보호대책 및 과전압 해석)

  • Hong, Dong-Suk;Jin, Hye-Young;Jung, Che-Kyun;Lee, Jong-Beom;Cho, Han-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.380-382
    • /
    • 2001
  • This paper describes the protection of insulation joint box in combined transmission line which is connected with the 154kV underground power cables. An actual power cable system was selected to establish modeling and to analyze. Modeling was established in EMTP and ATPDraw. Simulation was carried out according to the buried method of cable and connection method of CCPU. Results presented in this paper will be applied to another power cable systems.

  • PDF

The influence of filler for silicone rubber tracking (실리콘 고무의 트래킹에 미치는 충전재의 영향)

  • 허창수;장기순;조한구
    • Electrical & Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.344-350
    • /
    • 1996
  • Tracking is one of the biggist problems to be overcome in polymeric materials for outdoor insulators. But It can be decreased with the addition of filler such as alumina trihydrate (ATH). In this paper, the tracking of surface and evaluation of insulating ability at silicone rubber is investigated, using the salt fog test. At initial state, the peak leakage current and numbers by dry band arcing is increasing with increasing the filler level, but at aged state decreasing at high concentration filler samples. This is because the roughness of the surface may contribute to the increase in peak leakage cur-rent and numbers. As increasing the filler level, the insulating ability of materials is higher and weight loss is decreased. The mechanism of insulating failure is occurred by the erosion than the tracking and the erosion caused weight loss of 2 g.

  • PDF

Electric Field Analysis of Polymeric ZnO Surge Arrester for loading in Electric Traction (전철 탑재형 ZnO 고분자 피뢰기의 전계해석)

  • Lee, U.Y.;Jang, D.U.;Kang, S.H.;Lim, K.J.;Han, S.W.;Cho, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2293-2295
    • /
    • 1999
  • Polymeric ZnO surge arresters are used to protect the electric traction to limit the overvoltage invading into its inner electrical circuits. We have developed polymeric ZnO surge arresters design and investigated electric field analysis of its by FEM(Finite Element Method).

  • PDF

The Evaluation of Ageing Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring (누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가)

  • Kim, J.H.;Seo, K.S.;Moon, J.S.;Yang, G.J.;Cho, H.G.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2408-2410
    • /
    • 1999
  • The ageing process was checked by leakage current monitoring in Inclined-Plane Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the number of peaks in the ranges of 1-10, 10-20, 20-30, 30-40, 40-50, >50 mA. And, erosion depth was measured to be used as the index of the ageing. So, the results of leakage current components and erosion depth measurement were compared to find one or more components of which trends of changes were similar to that of erosion.

  • PDF

A Simulation on the Displacement Stress of Cement in Porcelain Insulators for Transmission Line (송전용 자기재 애자의 시멘트 변위 응력에 관한 시뮬레이션)

  • Han, S.W.;Cho, H.G.;Woo, B.C.;Jung, G.C.;Lee, D.I.;Choi, I.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.476-479
    • /
    • 2002
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied the effect of cement displacement resulting environmental ageing parameters on porcelain insulator mechanical properties for transmission line by simulation (ANSYS/NASTRAN program) and test methods. These simulation analysis and experimental results show that cement volume growth affects severely to be mechanical failure ageing.

  • PDF

Assessment Technique and Aging Test for EHV Porcelain Insulators (송전용 자기재 애자의 열화시험 평가기술)

  • Han, S.W.;Cho, H.G.;Park, K.H.;Jung, G.C.;Lee, D.I.;Choi, I.H.;Shin, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.480-483
    • /
    • 2002
  • This paper through shift norm of insulator and research by accident prevention countermeasure special skill authoritativeness verification of insulator and Long Term aging factor for power transmission analysis and evaluate and prove quality of insulator wish to. Assessment technique by aging of own porcelain insulator observes ageing factor for reciprocity comparison through several examinations. Through cool and heat accelerated Aging test, can measure the leakage current change amount that ensue to each Cycle. Can confirm own blazing fire factor as distribution freshness that ensue in HRB Test's hardness value.

  • PDF

Mechanical Strength Analysis and Property Test of Post Insulator for Substation and Generation (발.변전용 지지애자의 기계적 강도해석과 특성시험)

  • Park, K.H.;Cho, H.G.;Han, D.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.69-71
    • /
    • 2001
  • FRP has been used very much as high strength core materials for insulators because of its high strength and good insulation properties. In this study cantilever, tension and torsion stress were simulation along to the unidirection glass fiber. In addition, FRP was made by pultrusion method. This paper proposed the procedure of the finite element model updating and pretest using the commerical finite element code MSC.Nastran. To ehance the efficiency of experimental modal analysis. we proposed the process which is the selection of the locations and the number of measurement points for pre-test.

  • PDF

Characteristics of the Surge Protector for Underground Cable (지중케이블의 절연통 보호대책 및 방식층 보호장치의 특성)

  • Kim, S.S.;Cho, H.G.;Park, T.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.72-75
    • /
    • 2001
  • 전력케이블 선로에 가해지는 전압은 상시교류전압이외에 지락 등에 의한 사용주파과전압과 뇌써지와 같은 써지성 과전압이 있다. 써지성 과전압이 케이블 심선에 침입할 경우 종단접속부나 절연접속함의 접속점은 절연통 양단 및 시스와 대지간에 고전압이 발생하여 케이블심선-시스간 시스-대지간의 써지임피던스 비에 따라 과전압이 발생하며, 이와 같이 써지성 과전압이 방식층의 충격내전압치를 초과할 경우 방식층을 보호하기 위한 대책이 필요하며 그 보호장치로 절연통 보호장치를 사용하는 것이 일반적이다. 절연통에 대한 보호대책과, 설계 제작된 절연통 보호장치에 대한 주요시험항목을 실시하여 항목별 그 특성을 검토하고 절연통 보호장치의 지중송전선로에서 사용되는 조건인 열적내량을 검증하는 충격전류시험과 침수에 의한 기밀성능을 검증하는 내수성능시험을 실시함으로써 그 중요성을 인식할 수 있었다.

  • PDF