• Title/Summary/Keyword: 조직등가보상체

Search Result 3, Processing Time 0.016 seconds

Comparison and validation of Brass mesh bolus using tissue equivalent bolus in the breast cancer radiotherapy (유방암 방사선치료시 조직등가보상체와의 비교를 통한 Brass mesh bolus의 유용성 평가)

  • Bong, Juyeon;Kim, Kyungtae;jeon, Mijin;Ha, Jinsook;Shin, Dongbong;Kim, Seijoon;Kim, Jongdae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.93-101
    • /
    • 2017
  • Purpose: In breast cancer radiotherapy, brass mesh bolus has been recently studied to overcome disadvantage of conventional bolus. The purpose of this study is to investigate the stability of first introduced the brass mesh in the country, and evaluate the skin surface dose of that. Materials and Methods: The measurement of skin surface dose was evaluated to verify similar thickness of the Brass mesh bolus that compared conformal tissue equivalent bolus with 5 mm thickness. We used 6 MV photons on an ELEKTA VERSA linear accelerator and optically stimulated luminescent dosimeter (OSLD). In addition, two opposed beam using IMRT phantom was applied to comparative study of brass mesh bolus between tissue equivalent bolus. Results: The results showed that similar thickness of the Brass mesh bolus was 3 mm compared with 5 mm tissue equivalent bolus by measuring the skin surface dose of solid phantom. The surface dose for IMRT thorax phantom using 3 mm brass mesh bolus was about 1.069 times greater than that using tissue equivalent bolus. Conclusion: In this study, we found that the brass mesh bolus improved better reduction of skin sparing effect and dose uniformity than tissue equivalent bolus. However evaluation for various clinic cases should be investigated.

  • PDF

Dose Effect of Tissue Compensator for 6 MV X-Ray (두경부 방사선조사시 3차원조직보상체에 의한 피부선량)

  • Lee, Ho-Jun;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 1992
  • It is ideal thing to compensate tissue deficit without skin contamination in curvatured irradiation field of high energy photon beam. The 3-dimensional compensating technique utilizing tissue equivalent materials to ensure an adequate dose distribution and skin sparing effect was described. This compensator was made of paraffin ($70\%$) and stearin wax ($30\%$) compound. The parameters for evaluation of the effect on skin dose in application of compensator were considered in the size of the field, the thickness of the compensator and the source-to-axis distance. The results are as follows; the skin doses were not changed even though application of the compensator, but depended on the field size and the source-to-axis distance, and the skin doses were only slightly changed within $1\%$ relative errors as increasing the thickness of the compensator in these experiments.

  • PDF

A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray (고에너지 방사선치료용 조직등가보상체에 관한 고찰)

  • CHOI Tae Jin;HONG Young Rak;LIM Charn Soo;JEUNG Ho Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF