Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series (위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.889-894
    • /
    • 2019
  • Upper gastrointestinal series is an examination that uses X-rays. It is important to defend against exposure to radiation during upper gastrointestinal examination because the organs, such as thyroid gland, lens, breasts, and gonads, with relatively high biological sensitivity to radiation are distributed on the examination area. We have made a whole body phantom that can change the depth of organs. radiation dose of eye, thyroid gland, breast and gonads were measured by the same procedure as the actual upper gastrointestinal examination. When performed only fluoroscopy the mean dose reduction of lens, thyroid gland, breast and gonads was 62.2%. The mean dose reduction of lens, thyroid gland, breast and gonads was 59.0% when both fluoroscopy and spot shoot were performed. Therefore, when performed upper gastrointestinal examination it was confirmed that shielding of the lens, thyroid gland, breast and gonads was effective in decreasing the exposure dose. The manufactured human phantom can be used in measuring radiation dose for deep organ because it can adjust the height corresponding to the organs located in the human body.

Usefulness of Three-Dimensional CT Image in Meningioma Using Contrast Method (조영법을 이용한 뇌수막종에서 3차원 CT영상의 유용성)

  • Lee, Jun-Haeng;Baek, Sung-Eun;Lee, Sang-Bock;Kim, Yong-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2008
  • Because of the reason that the meningioma is enhanced lately, we started the study to maximally enhance the meningioma. we were to know the relation between meningioma and vessels in the skull and compared 3D CT angiography with the conventional angiography. we got the data from 6 patients performed by both 3D CT angiography and there were 5 cases in sphenoidal ridge and 1 case parasagittal sinus. Injecting the contrast media at 3 ml/sec, 120 ml and then the CT number reached 100, we started the study using the medical system Program(smart prep). The scan parameters were HS-Mode(1.25 mm / 7.5 mm) right after being injected all and reconstructed with 0.5 mm interval. We compared the study with the conventional angiography after reconstructing the images required by using 3D-Med software Program(Rapidia). Seeing the consequences, the maximum enhancing time in the menigioma is about 120~180 seconds after injecting the contrast media and we distinguished the relation between vessels and tumors at the time and 1 case showed us the aneurysm with a tumor clearly at the time too. It was very helpful to the operation that the 3D images required by injecting the contrast media to the patients with meningioma distingushed between tumors and vessels dimensionally.

  • PDF

Study on Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique (복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구)

  • Kang, Min;Choi, Namgil;Han, Jaebok;Kim, Wook;Jang, Yeongill;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • The purpose of this study is finding optimum contrast medium quantity during abdominal CT using dual energy technique. The study subjects are 30 patients who had received general single energy abdominal CT and received double energy technique follow-up abdominal CT. dual energy technique abdominal CT images were obtained after setting contrast medium quantities at 30%, 40%, 50%, 60% and 70% of contrast medium quantity at the time of single energy technique. Then the contrast enhancement (Hounsfield Unit; HU) was estimated by setting-up the regions of interest at aorta, inferior vena cava, hepatic portal vein and hepatic parenchymal. The obtained values were compared to the values of the same parts measured during single energy technique abdominal CT. The results of the study were as following. The 60% set up group had HU in aorta : $210.80{\pm}13.609$, IVC : $190.40{\pm}25.215$, hepatic portal vein : $198.40{\pm}21.232$ and hepatic parenchymal : $119.20{\pm}7.98$, The single energy abdomianl CT images had HU in aorta : $205.40{\pm}16.426$, IVC : $188.20{\pm}21.476$, hepatic portal vein : $195.40{\pm}22.744$ and hepatic parenchymal : $121.00{\pm}6.595$. Therefore, it is possible to obtain contrast enhancement by dual energy technique abdominal CT similar to the same by single energy technique abdominal CT by setting-up the quantity of contrast medium at 60% of contrast medium at the time of single energy technique abdominal CT. Based on the result of this study, it is possible to decrease existing quantity of contrast medium by _% and the injection velocity can be also decreased. Accordingly, it is believed that the result of study would be quite useful for patients who have renal function disorder, weak vein or side effect of contrast medium in the past.

Utility of Ultrasonography for Urinary Tract Infections of Infants (소아 요로 감염의 초음파 검사 유용성 검토)

  • Yoon, Chul-Ho;Kim, Yun-Jeong
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • In this study, we investigated utility of ultrasonography for urinary tract infections of infants. The results of the research is as follows : 1. The number of infants under one year old was 100 out of 122 infants who were diagnosed as a unitary infection. The ratio of males to females was 1.7 : 1. Seventy-seven infants who underwent three kinds of radiologic examinations such as kidney sonography (51%), $^{99m}TC$ DMSA-scan (42%), and VCUG (22%). 2. In comparison of correlation between kidney sonography and VCUG, the sensitivity of kidney sonography was 82% while the specificity of kidney sonography was 58%. In comparison of correlation between kidney sonography and $^{99m}TC$ DMSA-scan, the sensitivity of kidney sonography was 66% while the specificity of kidney sonography was 67%. 3. Utility of kidney sonography showed the highest efficiency when we considered pain, discomfort, a sense of shame, psychological stress when infants may undergo at the examination, side-effect of a contrast agent after the examination, and complication of exposure to radiation.

  • PDF

지혜 깊어지는 건강_건강검진이야기: 위장검사 위가 보내는 SOS신호 잡는다

  • Lee, Eun-Jeong
    • 건강소식
    • /
    • v.35 no.6
    • /
    • pp.16-17
    • /
    • 2011
  • 음식물을 받아들여 소화하는 위장. 최대 1,500ml 정도까지 커지는 위장은 식도와 연결된 분문으로 음식물을 받아 소화시키고 잠시 저장한 뒤 유문을 통해 십이지장으로 내려보낸다. 중요한 역할을 하는 만큼 이상이 생기면 소화 불량, 더부룩함, 배탈, 속 쓰림, 설사 등 여러 증상으로 SOS신호를 보내는데, 이 같은 경고를 쉽게 무시해 버리는 게 문제다. 특히 위암은 조기에 발견하면 90% 이상 완치될 수 있으므로 정기적으로 위장을 검사해야 한다. 내시경을 넣는 위내시경검사, 조영제를 마시고 X선 촬영을 진행하는 조영촬영검사가 대표적이다.

  • PDF

The Precaution Duty and the Product Liability for Adverse Reactions to the Contrast Media (조영제 부작용에 대한 주의의무와 제조물책임)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.305-311
    • /
    • 2007
  • Contrast medium is a useful drug for radiological examinations and usability of it gradually increases while it has some inevitable adverse reaction and it is difficult to predict the occurrence and the degree of adverse reactions. Although the patient consented permission for the use of contrast media, the hospital could not be exempted from the responsibility for the adverse contrast media reaction. During radiological contrast media examination, the radiologist and the contrast media producer have the duty of precaution, prediction and avoid adverse results. In addition, they have reliabi lity of patient remedy for neglecting the duty. Since contrast medium are manufactured or processed as movable properties, the manufacturers are bound to the product liability if damages occur due to the defects in pharmaceuticals. In consideration of the characteristics of product liability, it is necessary to demand high degree of duty of care and diligence from producer or to reduce patient's burden of proof in a product liability lawsuit. For securing compensation ability and liability implementation, products compensation liability insurance is required for contrast medium manufacturers. In conclusion, contrast medium producer has legal liability for adverse reactions and the contract concluded with producer and hospital including legal liability will reduce liability of hospital and radiologist, patient.

  • PDF

A study of contrast agent peak time using biomechanics factors experimental contrast medium infusion test using at contrast enhanced magnetic resonance angiography (조영증강검사 시 생체 요인을 이용한 조영제 peak time에 관한 연구)

  • Son, Soon-Yong;Kim, Yoon-Shin;Choi, Kwan-Woo;Seo, Sung-Mi;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.786-792
    • /
    • 2013
  • In this study was explored minimize side effects due to the additional injection of contrast medium and maintaining a high resolution imaging applied to the inspection and analysis of the contrast medium that affect the peak time biomechanics factors. Included 48 patients using the test bolus method, after measuring a patient's biomechanics factors of inspection before and during the test, correlation between contrast medium peak time and learn, matches the regression equation calculated and measured contrast medium peak time was assessed by the Bland Altman plot. Research result, inspections of SBP, HR contrast medium peak time and a significant negative correlation was, step 1, every increase, the contrast medium peak time significantly to -0.018 and -0.159 decreased, a fairly high concordance no difference between the two method. In conclusion, the regression equation using the existing methods, while maintaining excellent image quality that contrast medium is reduced to a patient, it can conclude that the alternative to the existing methods.

Evaluation of Usefulness in New Immobilization Device with 3D CT Angiography for Lower Extremity (전산화단층촬영검사에서 하지의 3D 혈관조영검사를 위한 새로운 고정기구의 유용성 평가)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.184-191
    • /
    • 2007
  • Our objective was to develop and evaluate a non-invasive device for rigid immobilization and surface disease non-contact of the table in the lower extremity during CT angiography. The immobilization device consists of two components. The patient's lower limb device stabilizing elements made of polyethylene resin soft materials, and pelvis parts foam pad is used for non-contact surface. In a Prospective study the lower extremity device was used in patients who underwent a CT angiography of the lower limb. Immobilization with our device was well tolerated by all patients. The quality of the resulting images in the popliteal and infrapopliteal region was rated by five-point scale. The rigid immobilization resulted in a complete absence of motion artifacts. The new device is an effective, well tolerated and easily used immobilization that is suitable of use in 3D lower extremity CT angiography.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.