• Title/Summary/Keyword: 조도 측정

Search Result 3,163, Processing Time 0.034 seconds

An Analysis of Classroom Illuminance with Simulation Program and Improvement of Classroom Illumination (시뮬레이션프로그램을 활용한 교실조도 분석 및 개선방안)

  • Shin, Hyun-Man;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.129-134
    • /
    • 2009
  • The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance state was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local illumination. As a result of conducting a simulation based on the mesurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and the kind of design considered illumination maintenance was called for.

  • PDF

An Analysis of Classroom Illuminance with Simulation Program end Improvement of Classroom Illumination (시뮬레이션 프로그램을 활용한 교실조도 분식 및 개선안)

  • Shin, Hyun-Man;Jang, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.14-23
    • /
    • 2009
  • The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local lighting. As a result of conducting a simulation based on the measurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and a design considering illumination maintenance was called for.

Variation of the Drag Force Acting on Vegetation Model Elements (식생 모형 요소를 이용한 항력 변화 검토)

  • Rhee, Dong-Sop;Lee, Du-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.665-665
    • /
    • 2012
  • 식생의 물리적 특성에 따라 조도의 관점에서 식생이 흐름에 미치는 영향도 많이 달라지게 된다. 일반적인 식생 조도 실험은 초본류를 대상으로 하고 있지만, 초본류 식생은 매우 유연하기 때문에 단일 개채가 흐름에 미치는 영향을 정량적으로 파악하는 것이 매우 힘들다. 따라서 단일 개체에 의한 조도 특성 보다는 식생군에 의한 조도계수 변화 특성을 알아내는 것이 보통 중요해진다. 하지만 조도의 관점에서 초본류와 달리 목본류는 삭생의 강성이 매우 크기 때문에 식생군의 군집으로서 특징보다는 개별 식생의 형상이 큰 역할을 수행하게 된다. 일반적으로 목본류는 수심에 따라 흐름에 영향을 주는 생체량(biosmass)이 수심에 따라 변화하지만, 줄기(trunk)의 경우 수심에 따라 생체량의 변화가 거의 없으며, 줄기의 강성 및 단면 모양이 큰 역할을 하게 된다. 또한 목본류는 실험 수로에 고밀도의 수목군을 형성하여 실험을 수행하는 것이 쉽지 않으므로 개별 식생이나 소규모 군체에 대하여 항력을 측정하여 조도를 평가하는 것이 일반적이다. 따라서 본 연구에서는 목본류의 줄기 부분이 흐름에 미치는 영향을 파악하기 위한 기초 연구로서 원기둥이나 사각기둥과 같은 식생 모형 요소를 이용하여 식생 줄기를 구현하였고, 식생 형상 및 식생 직경 등을 달리하여 침수 조건 변화에 따른 항력 변화 특성을 검토하였다.

  • PDF

타원계측을 이용한 나노바이오 융합기술

  • 조현모;조용재;제갈원
    • Journal of the KSME
    • /
    • v.44 no.10
    • /
    • pp.57-61
    • /
    • 2004
  • 이 글에서는 편광을 이용한 광학계측기술인 타원계측방법의 나노측정기술과 나노바이오 측정기술로의 응용에 대하여 소개한다.

  • PDF

Development of a Tensile Force Measurement Device of Long Duration (인장력 상시 측정장치 개발에 관한 연구)

  • Shin, Kyung Jae;Hwang, Yun Ha
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.435-445
    • /
    • 2003
  • Tension member is one of the most important elements in tension structure. An economical and reliable measurement method of a member's tensile force has yet to be developed, however. Several conventional measurement methods have some disadvantages when used for long-term, on-site measurement. A new tension-force measurement device was proposed to resolve measuring problems. Its principle was to use the bending part of the device as an elastic spring. The lateral deformation of the bending part due to tensile force can be measured to monitor the tensile force. This device was inserted in the tension member like a turn-buckle. Lateral deformation may be measured in the field at any time for the purpose of maintaining structures. Finite element analysis was used to design the shape and parametric study. Six specimens were tested within the elastic range. The test result showed that the elastic behavior or the bending part was consistent with the analysis' results.

A noncontact optical roughness measurement technique of ground surface by light scattering (광산란을 이용한 연삭표면의 비접촉식 광학적 조도측정기술)

  • 임동열;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1303-1311
    • /
    • 1988
  • Described is method for development of an optical roughness measurement sensor for in-subequality assurance in the precision grinding. Main approach is made based upon the Brckmann's light scattering theory, in which general solutions of the optical scattering behaviour are given under many simplifying assumptions on the model of the surfaces illuminated. For the ground surface, the assumptions are verified through computer simulation and experimental work in order to examine the validity of Beckmann's theory on predicting the optical responses according to the roughness variation. As a result, an optical monitoring strategy is derived which can evaluate the roughness value of the ground surface by statistically detecting the pattern of intensity distribution of the scattered light. Finally, the strategy is proven by comparing with the results using the stylus method.

A Study of the Velocity Distribution and Vorticity Measurement in the Pump Sump Using PIV (PIV를 이용한 흡수조 내 유속분포 및 와류강도 측정에 대한 연구)

  • Byeon, Hyun Hyuk;Kim, Seo Jun;Yoon, Byung Man
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.145-156
    • /
    • 2020
  • The climate change occurring all over the world increases the risk, specially in urban area, Accordingly, rainwater pumping station expansion is required than before. In order to increase the efficiency of the rainwater pumping station, the analysis of flow characteristics in the pump sump is needed for vortex control. Many efforts have been made to illuminate the vortex behavior using PIV, but any reliable results have not been obtained yet, because of the limitations in image capturing and dependency of measured velocity values on the interrogation area and time interval used for velocity calculation. In this study, therefore, experiments were carried out to find out the limitation of PIV and estimate the validation of the velocity values associated with the analysis parameters such as interrogation area, time interval, grid size. For the experimental condition used in this study, the limitation of PIV and the effects of parameters on the velocity estimation are presented.