• Title/Summary/Keyword: 젤 영상 분석

Search Result 13, Processing Time 0.027 seconds

Gel Image Matching Using Hopfield Neural Network (홉필드 신경망을 이용한 젤 영상 정합)

  • Ankhbayar Yukhuu;Hwang Suk-Hyung;Hwang Young-Sup
    • The KIPS Transactions:PartB
    • /
    • v.13B no.3 s.106
    • /
    • pp.323-328
    • /
    • 2006
  • Proteins in a cell appear as spots in a two dimensional gel image which is used in protein analysis. The spots from the same protein are in near position when comparing two gel images. Finding out the different proteins between a normal tissue and a cancer one is important information in drug development. Automatic matching of gel images is difficult because they are made from biological experimental processes. This matching problem is known to be NP-hard. Neural networks are usually used to solve such NP-hard problems. Hopfield neural network is selected since it is appropriate to solve the gel matching. An energy function with location and distance parameters is defined. The two spots which make the energy function minimum are matching spots and they came from the same protein. The energy function is designed to reflect the topology of spots by examining not only the given spot but also neighborhood spots.

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF

Automated System on Extracting Digital Pattern for TDGS Image Analysis (TDGS 영상 분석을 통한 자동적 디지털 패턴의 추출)

  • Chang, Hwan;Park, You-Na;Lee, Bog-Ju
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05a
    • /
    • pp.707-710
    • /
    • 2003
  • 본 논문은 2차원 전기영동에 의해 나타나는 TOGS 영상을 분석하기 위한 시스템으로 실험적인 특성상 젤 위에 나타나는 반점들의 불규칙한 요소들이 많고 영상의 상태가 좋지 않은 경우 명암도가 떨어지는 반점들의 구분이 힘들게 된다. 기존의 전문가의 육안에 의한 TDGS 영상 분석은 그러한 불안적 요소들에 대해 유연하게 대처할 수 있는 능력이 있었다. 하지만, 그러한 예외적인 경우를 컴퓨터가 처리하기 위해서는 영상의 지역적 상태에 맞는 융통성 있는 영상처리 과정이 필요하고, 실제 분석에 사용되지 않는 반정들을 제외한 유효한 디지털 패턴의 판별이 요구된다. 이에 본 논문에서는 영상의 지역적 특성을 효과적으로 반영한 동적 이진화 방법을 통해 후보 패턴들을 추출하고, 모든 샘플들의 기준이 되는 Reference 패턴과 후보 패턴의 point matching 과정을 통해 디지털 패턴을 추출한다.

  • PDF

The Algorithm of Protein Spots Segmentation using Watersheds-based Hierarchical Threshold (Watersheds 기반 계층적 이진화를 이용한 단백질 반점 분할 알고리즘)

  • Kim Youngho;Kim JungJa;Kim Daehyun;Won Yonggwan
    • The KIPS Transactions:PartB
    • /
    • v.12B no.3 s.99
    • /
    • pp.239-246
    • /
    • 2005
  • Biologist must have to do 2DGE biological experiment for Protein Search and Analysis. This experiment coming into being 2 dimensional image. 2DGE (2D Gel Electrophoresis : two dimensional gel electrophoresis) image is the most widely used method for isolating of the objective protein by comparative analysis of the protein spot pattern in the gel plane. The process of protein spot analysis, firstly segment protein spots that are spread in 2D gel plane by image processing and can find important protein spots through comparative analysis with protein pattern of contrast group. In the algorithm which detect protein spots, previous 2DGE image analysis is applies gaussian fitting, however recently Watersheds region based segmentation algorithm, which is based on morphological segmentation is applied. Watersheds has the benefit that segment rapidly needed field in big sized image, however has under-segmentation and over-segmentation of spot area when gray level is continuous. The drawback was somewhat solved by marker point institution, but needs the split and merge process. This paper introduces a novel marker search of protein spots by watersheds-based hierarchical threshold, which can resolve the problem of marker-driven watersheds.

(Image Analysis of Electrophoresis Gels by using Region Growing with Multiple Peaks) (다중 피크의 영역 성장 기법에 의한 전기영동 젤의 영상 분석)

  • 김영원;전병환
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.5_6
    • /
    • pp.444-453
    • /
    • 2003
  • Recently, a great interest of bio-technology(BT) is concentrated and the image analysis technique for electrophoresis gels is highly requested to analyze genetic information or to look for some new bio-activation materials. For this purpose, the location and quantity of each band in a lane should be measured. In most of existing techniques, the approach of peak searching in a profile of a lane is used. But this peak is improper as the representative of a band, because its location does not correspond to that of the brightest pixel or the center of gravity. Also, it is improper to measure band quantity in most of these approaches because various enhancement processes are commonly applied to original images to extract peaks easily. In this paper, we adopt an approach to measure accumulated brightness as a band quantity in each band region, which Is extracted by not using any process of changing relative brightness, and the gravity center of the region is calculated as a band location. Actually, we first extract lanes with an entropy-based threshold calculated on a gel-image histogram. And then, three other methods are proposed and applied to extract bands. In the MER method, peaks and valleys are searched on a vertical search line by which each lane is bisected. And the minimum enclosing rectangle of each band is set between successive two valleys. On the other hand, in the RG-1 method, each band is extracted by using region growing with a peak as a seed, separating overlapped neighbor bands. In the RG-2 method, peaks and valleys are searched on two vertical lines by which each lane is trisected, and the left and right peaks nay be paired up if they seem to belong to the same band, and then each band region is grown up with a peak or both peaks if exist. To compare above three methods, we have measured the location and amount of bands. As a result, the average errors in band location of MER, RG-1, and RG-2 were 6%, 3%, and 1%, respectively, when the lane length is normalized to a unit value. And the average errors in band amount were 8%, 5%, and 2%, respectively, when the sum of band amount is normalized to a unit value. In conclusion, RG-2 was shown to be more reliable in the accuracy of measuring the location and amount of bands.

Diagnostic Performance of Rectal CT for Staging Rectal Cancer: Comparison with Rectal MRI and Histopathology (직장암 병기결정에서 직장 CT의 진단능: 직장 MRI 및 병리결과와의 비교분석)

  • Seok Yoon Son;Yun Seok Seo;Jeong Hee Yoon;Bo Yun Hur;Jae Seok Bae;Se Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1290-1308
    • /
    • 2023
  • Purpose To compare the diagnostic performance of rectal CT with that of high-resolution rectal MRI and histopathology in assessing rectal cancer. Materials and Methods Sixty-seven patients with rectal cancer who underwent rectal CT with rectal distension using sonographic gel and high-resolution MRI were enrolled in this study. The distance from the anal verge/anorectal junction, distance to the mesorectal fascia (MRF), extramural depth (EMD), extramesorectal lymph node (LN) involvement, extramural venous invasion (EMVI), and T/N stages in rectal CT/MRI were analyzed by two gastrointestinal radiologists. The CT findings of 20 patients who underwent radical surgery without concurrent chemoradiotherapy were compared using histopathology. Interclass correlations and kappa statistics were used. Results The distance from the anal verge/anorectal junction showed an excellent intraclass correlation between CT and MRI for both reviewers. For EMD, the distance to the MRF, presence of LNs, extramesorectal LN metastasis, EMVI, T stage, and intermodality kappa or weighted kappa values between CT and MRI showed excellent agreement. Among the 20 patients who underwent radical surgery, T staging, circumferential resection margin involvement, EMVI, and LN metastasis on rectal CT showed acceptable concordance rates with histopathology. Conclusion Dedicated rectal CT may be on par with rectal MRI in providing critical information to patients with rectal cancer.

A Study on the Analysis of Gel Images of Genes and Molecules (유전자 및 물질의 젤 영상 분석에 관한 연구)

  • 김영원;전병환
    • Proceedings of the IEEK Conference
    • /
    • 2001.06c
    • /
    • pp.33-36
    • /
    • 2001
  • With all the researches to define human genom and to look for some new bio-activated material in the bio-technology field recently, it is more highly needed to analyse DNA or so called Material than ever before. First, the lanes are extracted based on histogram analysis and projection technique. And then three other approaches are applied for band extraction: SB, RG-1, and RG-2. In SB method, a search line is set dividing each lane equally and vertically to find peaks and valleys. And according to them, minimum enclosing rectangle of each band is determined. In RC-1 approach, on the other hand, band areas are extracted by region growing with the peaks as seeds, avoiding the overlap with the neighboring bands. In RC-2 approach, peaks and valleys are searched in two lines that trisect the lane vertically, and the pair of peaks in the same band are determined, and then used to grow the region. To compare the accuracy of the three suggested methods, we measure the location and amount of bands. The result shows that the mean deviation of the location is 0.06, 0.03, and 0.01 for SB, RG-1, and RC-2 respectively. And the mean deviation of the amount of bands is 0.08, 0.05, and 0.02 for SB, RG-1, and RG-2 respectively. In conclusion, the RG-2 method suggested in this paper appears to be the most reliable on the degree of the accuracy in measuring the location and amount of bands

  • PDF

Signal Change of Normal Saline by Oxygen Injection in FLAIR Image (산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.

Measurements of $T_1$-and $T_2$-relaxation Time Changes According to the Morphological Characteristics of Gold Nanoparticles (GNPs) (금 나노 입자의 형태적 특성에 따른 $T_1$, $T_2$ 이완 시간의 변화 측정)

  • Jang, M.Y.;Han, Y.H.;Mun, C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.48-56
    • /
    • 2011
  • Purpose : The aim of this study is to measure the typical MR variables such as $T_1$- and $T_2$-relaxation times according to morphological characteristics of gold nanopartides as a preliminary study to perform theragnosis using local heating by gold nanopartides. Materials and Methods : Two types of gold nanoparticles were used. Spheres were synthesized by various methods and stirring speed. Rods were synthesized by adding various concentrations of sphere nanopartides. Gold nanopartides were mixed with 2% agarose gel at 1:1 ratio and then signals were acquired using a 1.5T MRI. For the measurements of $T_1$-and $T_2$-relaxation times, TR and TE were varied, respectively. The results were acquired through $T_1$ and $T_2$ curves based on the intensities of MR image using self-developed software. And Statistical analysis was performed. Results : $T_1$ times were measured 1.86 sec and 2.08 sec for sphere and rod, respectively. On the other hands, $T_2$ times were measured 57 ms and 35.45 ms for sphere and rod. Conclusion : The changes of the MR variables according to the morphological characteristics of the gold nanopartides were confirmed. Optimal MR imaging conditions can be obtained by choosing proper TR and TE according to the type of nanoparticles.

The Creative Usage of Colors in Films (영화에 있어서 색상의 창의적인 사용)

  • Park, Jaehong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • We will analyze how color is used creatively in essential work, Red Deser, directed by Michelangelo Antoioni, one of the most unique film director in film history. in Red Desert, Antonioni especially tried to focus on the use of color to develop the narrative. Therefore, through the analysis of the Red Desert, this paper will endeavor to support the perspective that the role of color is not only a mere backdrop but has the primary funtion of storytelling in this film.