• 제목/요약/키워드: 제하 컴플라이언스

검색결과 21건 처리시간 0.025초

SA508-3재의 제하컴플라이언스법과 하중비해석을 이용한 파괴저항곡선 평가 (J-R Curve Characterization by Load Ratio Analysis and Unloading Compliance Method for SA508 C-3 steel)

  • 임만배;차귀준;윤한기;안원기
    • 한국해양공학회지
    • /
    • 제12권1호
    • /
    • pp.65-75
    • /
    • 1998
  • The fracture resistance curve is one of most important and design techniques employed in nuclear pressure vessel structures. This study is to evaluate the J-R curve characteristics for the SA508C-3 by the unloading compliance method and load rato analysis. The effect of strain aging for the exponential correlation of the J-R curve in this metal are investigated at room temperature, 20$0^{\circ}C$ and 30$0^{\circ}C$. The load ratio analysis method can evaluate the J-R curve by using the simple tension load-displacement curve only without the repeat of the unloading and loading. Therefore, the analysis by the proposed load ratio method has a merit, in comparison with the unloading compliance method, which can measure the crack length without the precision measurement equipment.

  • PDF

혼합모드 하중하에서 제하 컴플라이언스법에 의한 파괴 인성 측정 (Measurement of Fracture Toughness JC Under Mixed Mode Loading Using Unloading Compliance Method)

  • 심재룡;이영숙;김도형;범현규;강기추
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.113-120
    • /
    • 2002
  • Experimental procedure to measure fracture toughness (J$_{c}$) under mixed mode loading using CTS(Compact Tension-Shear) specimens is described. It\`s loading angle ranges from 0$^{\circ}$ to 45$^{\circ}$ with interval of 157. The general outline of experimental procedure is similar to that of ASTM E8l3-89 fur mode I fracture. Equations fur determining J-integral is quoted from the authors' previous works. The relation between unloading compliance and physical crack size was calibrated. As an example, fracture toughness of aluminum alloy 2024p-7361 was measured and some reasonable results of J$_{c}$ with various loading angles were obtained.

제하 컴플라이언스법에 의한 SA533B강의 $J_1C$ 및 J-R 곡선에 미치는 열시효 영향 (Effects of Accelerated Iso-Thermal Aging on Elastic-Plastic Fracture Toughness and Fracture Resistance Curve by Unloading Compliance Method in SA533B Low Alloy Steel)

  • 윤한기;차귀준
    • 한국해양공학회지
    • /
    • 제8권2호
    • /
    • pp.157-165
    • /
    • 1994
  • Effect of an accelerated iso-thermal aging (375 degree C x 66days, 375 degree C x 200days) on elastic-plastic fracture resistance curve were examined in SA533B low alloy steel. Fracture toughness test are conducted by unloading compliance method at room temperature. But the apparent negative crack growth phenomenon, usually arise in partial unloading compliance test. The phenomenon of negative crack growth may be eliminated by the offset technique. There is no effect of aging on J sub(IC) and dJ/da in iso-thermal aged (375 degree C x 66 days) specimen, but there is very little effect in iso-thermal aged (375 degree C x 200 days) specimen.

  • PDF

고주파 전기저항 용접강관의 제하 컴플라이언스법에 의한 파괴인성 평가 (Evaluation on fracture toughness of high frequency electric resistance welded steel pipe by unloading compliance method)

  • 오세욱;윤한기;안광주
    • Journal of Welding and Joining
    • /
    • 제5권2호
    • /
    • pp.44-52
    • /
    • 1987
  • The fracture toughness, $J_{IC}$ of high frequency electric resistance welded steel pipe for smooth and side-grooved CT specimen was evaluated by unloading compliance method. The crack growth, .${\delta}a$ was obtained from the equation of Donald and Saxena & Hudak, and $J_{IC}$ was determined from the curve of J-${\delta}a$ relations. The crack growth on the experiment using unloading compliance method is underestimated as compared with ${\delta}a$ measured directly by the SEM, so the reliability of $J_{IC}$ from saxena & Hudak equation is large than that from Donald. The $J_{IC}$ value of side-grooved CT Specimen is estimated less than that of smooth, and this is the effect of the side-groove, the shear-lip of crack tip and the reduction of crack tunnelling phenomena.

  • PDF

제하 컴플라이언스법 및 직류전위차법을 이용한 Zr-2.5Nb 압력관 휘어진 CT 시편의 균열시작 평가 (Evaluation of the Crack Initiation of Curved Compact Tension Specimens of a Zr-2.5Nb Pressure Tube Using the Unloading Compliance and Direct Current Potential Drop Methods)

  • 정현철;안상복;김영석
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1118-1122
    • /
    • 2005
  • The direct current potential drop (DCPD) method and the unloading compliance (UC) method with a crack opening displacement gauge were applied simultaneously to the Zr-2.5Nb curved compact tension (CCT) specimens to determine which of the two methods can precisely determine the crack initiation point and hence the crack length for evaluation of their fracture toughness. The DCPD method detected the crack initiation at a smaller load-line displacement compared to the UC method. As a verification, a direct observation of the fracture surfaces on the curved compact tension specimens was made on the CCT specimens experiencing either 0.8 to 1.0 mm load line displacement or various loads from $50\%\;to\;80\%$ of the maximum peak load, or $P_{max}$. The DCPD method is concluded to be more precise in determining the crack initiation and fracture toughness, J in Zr-2.5Nb CCT specimens than the UC method.

극저온용 구조재료의 파괴인성평가법에 관한 연구 (A study on the fracture toughness evaluating method for cryogenic structural material)

  • 권일현;정세희
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.64-72
    • /
    • 1998
  • This paper was undertaken to develop the fracture toughness testing method using small and single specimen compared to the conventional method in evaluating elastic-plastic fracture toughness of the superconducting magnet structural material at cryogenic temperature. The elastic-plastic fracture toughness test was conducted by using the unloading compliance method recommended by ASTM E813-89 to accomplish the above purpose. And, the 20% side-grooved 0.5TCT and 1TCT specimens were used to evaluate the fracture toughness by using as possible as miniaturized CT specimen. The unloading compliance method was a very useful method in evaluating elastic-plastic fracture toughness at cryogenic temperature. It could be taken valid fracture toughness values by using 20% side-grooved 0.5TCT specimen recommended by ASTM E813-89.

J적분을 이용한 원자력 압력용기강의 파괴인성치의 결정 (A method of Determination of Fracture Toughness of Reactor Pressure Vessel Steel by J Integral)

  • 오세욱;임만배;김진선
    • 한국해양공학회지
    • /
    • 제9권1호
    • /
    • pp.111-119
    • /
    • 1995
  • The elastic-plastic fracture toughness($J_{IC}$) and fracture resistance (J-R curve) of SA508-3 alloy steel used for nuclear reactor pressure vessel are investigated by using CT-type specimens. Fracture toughness tests are conducted by unloading compliance method and multiple specimen method at room temperature, -2$0^{\circ}C$ and 20$0^{\circ}C$. The apparent negative crack growth phenomenon which usually arises in partial unloading compliance test is well known. The negative crack growth phenomenon in determining J sub(IC) or J-R cure from partial unloading compliance experiments may be eliminated by the offset technique. In this study, the evaluation of $J_{IC}$ multiple specimen method recommended by the JSME gives the most reliable results by using half-size CT(similar-type) specimens.

  • PDF

실배관 시험편의 균열 길이 측정에 관한 연구 (A Study on the Measurement of the Crack Length for the Real Scale Pipe Specimen)

  • 박재실;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.397-402
    • /
    • 2003
  • Fracture resistance curves for concerned materials are required in order to perform elastic-plastic fracture mechanical analyses. Fracture resistance curve is built with J-integral values and crack extension values. The objective of this paper is to apply the load ratio method to the measurement of the crack length for the real scale pipe specimen. For these, the fracture test using the real scale pipe specimen and finite element analyses were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method and the load ratio method was used to measure the crack extension and the length for the real scale pipe test. Finite element analyses about the compliance of the pipe specimen were executed for applying the load ratio method according to the crack length.

  • PDF

탄소강의 탄소성파괴인성 $J_IC$ 평가에 관한 연구 (A Study on the Elasto-Plastic Fracture Toughness $J_IC$ Evaluation of Carbon Steel)

  • 김희송;안병욱
    • 한국정밀공학회지
    • /
    • 제6권3호
    • /
    • pp.90-99
    • /
    • 1989
  • In this study, J-integral values obtained by various methods, i.e, R-Curve, Unloading Compliance, Strectched Zone Width [SZW], and Acoustic Emission [AE] methods are investigated. Elasto-plastic fracture toughness [$J_IC$] estimations by R-curve method are overestimated than those by SZW method, and those by unloading compliance method is around middle value of them. And the difference between them is little. The $J_IC$ value by AE method was almost agreed with that by SZW, and then proved to be useful. Crack propagation mechanism on fractography is a stable ductile fracture. For the identification of ductile fracture, both fractography analysis and AE method were applied to estimate the characteristics more precisely.

  • PDF

가스배관재의 탄소성파괴인성에 미치는 측면홈영향 (Effect of Side Grooved on the Elastic Plastic Fracture Toughness of Gas Piping Meterial)

  • 임만배;차귀준;윤한기;김정호
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.350-356
    • /
    • 2001
  • SG-50 steel is an important material and used for manufacturing a pressure vessel which the gas piping. In this investigation, the elastic plastic fracture toughness of this material is evaluated by the an unloading compliance method according to the ASTM E813-97 and E1152-97 method on the smooth and side groove 1CT specimens. The effect of smooth and side groove is studied on the elastic plastic fracture toughness. The side grooved specimen is very useful in estimation of the J$_{IC}$. Because it is much easier than the smooth specimen to the onset of the ductile tearing by the R curve method. Besides, it improves the accuracy of toughness values, decreases the scattering of them and tunneling and shear lip by the side groove.e.

  • PDF