• Title/Summary/Keyword: 제진형

Search Result 93, Processing Time 0.024 seconds

Implementation of IoT System for Wireless Acquisition of Vibration and Environmental Data in Distributing Board (제진형 배전반의 진동 및 환경 데이터수집을 위한 IoT 시스템 구현)

  • Lee, Byeong-Yeong;Lee, Young-Dong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.199-205
    • /
    • 2021
  • The distributing board in directly installed on the ground or the bottom surface of the building, and when vibrations such as earthquakes or external shocks occur, the possibility of damage or malfunction of electric components such as internal power devices, wiring, and protection relays increases. Recently, the need for a seismic type distributing board is increasing, and research and development of a distributing board having a vibration damping function and product launch are being conducted. In this paper, an IoT-based data collection device system capable of measuring vibration and environmental data of distributing board was designed and implemented. When vibration occurred on the distributing board, data was stored and visualized in the MySQL DB through Node-RED for monitoring and data storage using the MQTT protocol for reliable messaging transmission. The test was conducted by attaching the IoT device of the distributing board, and data was collected in real-time and monitored through Node-RED.

레버 링키지를 이용한 능동형 제진 시스템 개발

  • 문준희;박희재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.50-50
    • /
    • 2004
  • 능동형 제진 시스템은 전기 등의 에너지 공급을 받아 주변의 진동을 차단하는 시스템이다. 일반적으로 이러한 시스템을 위해서는 압전 소자 등의 높은 힘과 강성을 가지며 분해능이 좋은 구동기를 사용한다. 이러한 구동기 자체의 크기로 인해서 가이드의 길이가 커져 강성이 낮아지는 점과 압전 소자의 구동 거리가 짧은 점을 보완할 수 있는 레버 링키지와 정밀 스테이지를 이용한 능동형 제진 시스템을 개발하였다.(중략)

  • PDF

Integrated Analysis and Design Technologies for a Structure with Control Devices (구조물-제진장치 통합 해석 및 설계 기술)

  • Lee, Sang-Hyun;Chung, Lan;Kang, Kyung-Soo;Hwang, Jae-Seung;Park, Ji-Hun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.388-391
    • /
    • 2010
  • 본 논문에서는 풍하중을 받는 구조물의 응답을 보다 적극적으로 저감시킴으로써 구조물의 안정성과 사용성을 개선하기위한 능동제어 알고리즘을 송도 자유무역 지구에 건설중인 포스코건설 사옥에 수치해석을 통해 적용하여 그 효과를 검증하였다. 수치해석에 의한 시뮬레이션 결과를 보면 최대 제어력이 제한이 된 비선형 제어기가 LQR 제어기와 등등한 제어효과를 가지고 있는 것으로 나타났으며, 제어력의 측면에서 본다면 비선형 제어기법이 더욱 유리한 것을 알 수 있다. 또한, 본 연구에서는 구조물과 질량형 제진장치의 상호작용을 고려하여 통합적으로 제진효과를 해석하고, 이를 바탕으로 제진장치를 설계할 수 있는 소프트웨어를 개발하였다. 구조물의 모드정보에 기초한 축소모델을 구축하고 제진장치의 설계 및 제진성능 평가를 수행하고 사용성을 평가하게 된다. 전체 소프트웨어는 질량형 제진장치의 설계프로그램과 질량형 제진장치의 종류별 대안설계결과를 등가감쇠비로 표현하여 비교평가하는 두 개의 모듈로 이루어져 있으며 전자는 비제어구조물 해석 모듈 및 TMD, TLD, TLCD, AMD를 대상으로 해석 및 설계를 수행하는 총 5개의 하부 모듈로 구성된다. 본 소프트웨어를 현재 TLCD가 설치되어 있는 인천 송도 국제업무지구의 주상복합건물에 적용하여 TMD, TLD, TLCD, AMD의 대안설계를 실시하였다.

  • PDF

Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test (유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가)

  • Heur, Moo-Won;Chun, Young-Soo;Hwang, Jae-Seung;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.23-34
    • /
    • 2015
  • Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.

A Study on Optimum Design of an Unconstrained Damping Steel Plate by Using Viscoelastic Damping Material (점탄성 제진재를 이용한 비구속형 제진강판의 최적설계에 관한 연구)

  • 유영훈;양보석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.292-297
    • /
    • 1995
  • 본 연구에서는 점탄성 제진층이 탄성기판의 한 면에 피복된 2층 제진강파느이 모달 손실계수의 관점으로부터 부분도포에 의한 최적설계의 가능성을 검토하였다. 즉, 일정한 두께로 전면 도포되어 있는 2층의 제진층을 작은 크기의 조각(piece)으로 분할한 경우, 각각의 조각이 손실계수에 미치는 영향을 손실계수의 증감율로써 평가하고, 최소 영향부위의 조각을 최대 영향부위에 이동하여, 동일 질랴의 제진재로 최대의 제진효과를 얻을 수 있는 제진재의 최적 설계법을 제안한다. 수치계산은 주변고정 평판의 (1,1)(1,2)(1,3) 모드 성분에 대해 수행하여 최적설계에 의한 손실계수의 증가와 그때 제진재의 배열형상을 조사하였다. 본 수법에 의해 얻어진 결과는 실험결과와 비교 검토하여 본 최적화 수법의 타당성을 확인하였다. 또한, 제진재의 전면도포의 경우는 Ross-Ungar-Kerwin모델에서도 계산을 수행하여 본 수법의 결과와 비교하였다.

  • PDF

Applicability of the Hysteretic Steel Dampers to the Shear-wall Dominant Apartment Buildings (벽식구조 아파트건물의 강재이력형 댐퍼 적용성 평가)

  • Chun, Young-Soo;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.407-413
    • /
    • 2012
  • In this study, the possibility of applying the damping devices to shear-wall dominant apartment buildings(SDA) was examined. In order to achieve research objectives, ASCE/SEI 7-10 design procedure for structures with damping systems applied to four representative apartment buildings which are under design or previously designed with the shear-wall dominant system, and the performances of damping devices were investigated. It is shown that in order to secure the seismic performance of SDA by using dampers, the stiffness of the dampers should be very large because of the effects of shear walls with the high elastic stiffness. But since this large stiffness is highly difficult to implement in reality, prudent decisions have to be made in designing the SDA with damping system and friction dampers with the high initial stiffness are more effective than hysteretic steel dampers.

Test of RC Structures with Friction Damper (마찰형 댐퍼가 있는 RC 구조물에 관한 실험적 연구)

  • Kim, Young Ju;Ahn, Tae Sang;Lee, Chang Hwan;Kim, Sang Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • 국내의 내진설계 기준은 1988년에 처음 도입되었으며, 최근 점차 강화되고 있는 실정이다. 공동주택에 주로 적용되는 전단벽식 구조시스템에서 증가된 지진력에 저항하기 위해서는 벽량과 철근이 증가하게 되어 공사비가 상승하게 된다. 이러한 단점을 보완하기 위한 제진설계의 필요성이 대두되고 있는 실정인데, 기존의 제진장치는 주로 가새형 또는 벽체형을 대부분이라 평면계획에 제약이 있다. 따라서 전단벽식 구조의 공동주택의 제진설계 시에는 우리나라와 같은 중 약진 지역에 적합하고 저렴한 비용으로 충분한 내진성능과 평면의 가변성을 확보할 수 있는 댐퍼의 선택이 필요하다. 본 연구의 목적은 기존의 가새형 및 벽체형 제진장치의 국내 공동주택 적용시의 문제점인 평면의 가변성 확보에 유리하고, 수동형 제진장치의 장점을 추구할 수 있는 마찰댐퍼를 삽입한 커플링보 제진시스템의 내진성능을 조사하는 것이다. 내진성능을 평가하기 위해서 실대형 커플링보 실험체를 계획하고 제작하였다. 실험체는 2개로 구성되어 있으며, 하나는 기존의 철근배근 상세를 갖는 철근콘크리트 커플링보 실험체와 커플링보에 마찰댐퍼가 삽입된 실험체이다. 횡하중에 대한 성능을 평가하기 위해서 유사정적 반복가력실험을 실시하였다. 엑츄에이터로부터 실험체 상보의 가력지그를 통해 하중이 전달되도록 하였으며, 가력은 최초 0.25%의 층간변형각부터 변위제어를 통해 목표 층간변형각인 1.5% 이상까지 진행되도록 하였다. 실험결과, 두 실험체의 이력곡선과 에너지 흡수능력을 평가하였다. RC 실험체는 핀칭현상이 관찰되었고, 가력이 진행됨에 따라 커플링보와 벽체에서의 균열이 확산되어 종국적으로 취성적인 커플링보의 전단파괴가 발생하였다. 마찰댐퍼를 삽입한 실험체는 계획된 마찰거동이 잘 발휘되어 목표 층간변형각인 1.5%까지 이선형거동이 잘 나타났다. 최대 내력은 RC 실험체가 3배 이상 크지만, 누적층간변형각에 따른 에너지 흡수능력은 마찰댐퍼 실험체가 2배 이상 우수한 결과를 보였으며, 커플링보 및 벽체에서의 균열이 매우 저감되었다.

  • PDF

Structural Analysis using Equivalent Models of Active Control Devices (능동형 제진장치의 등가모델을 이용한 구조해석)

  • Park, Ji-Hun;Yun, Soo-Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.339-346
    • /
    • 2012
  • In this paper, equivalent models for active control devices are proposed so that building structures with such devices are analyzed using commercial structural analysis programs for the assessment of the structural members under active vibration control. Equivalent link models represent active control device with a virtual linear spring and dashpot, and equivalent force models are control force history acting at the installation point in structural models. Active controllers are designed based on the reduced-order models for a vertical cantilever model and a high-rise building model and corresponding equivalent models are determined from control gain matrices. Based on acceleration, displacement and member force responses, the effectiveness of the equivalent models is verified. As a result, proposed equivalent models, of which equivalent link model showed better performance, appear to enable detailed investigation of structural behavior to the extent of member force level.

A Control Algorithm of Hybrid Mass Damper Using Displacement Feedback (변위 피드백을 이용한 하이브리드 제진장치의 제어 알고리즘)

  • Kim, Byoung-Jeon;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.140-143
    • /
    • 2011
  • 본 연구에서는 준능동형 제진장치로 복합형 제진장치(HMD, Hybrid Mass Damper)의 운용에 요구되는 제어알고리즘 개발에 대한 연구를 진행하였다. 제어력을 산정하기 위한 알고리즘 내장화 과정에서 구조물의 상태를 피드백하기 위해서는 구조물의 가속도를 계측하고 이로부터 변위, 속도를 추정하게 되는데 여기서 발생하는 오차의 문제점을 개선하기 위하여 GPS의 실시간 변위측정기술을 활용하여 변위를 직접 입력하면서 구조물의 응답을 제어할 수 있는 알고리즘을 구성하려 한다. 이 때 측정된 데이터의 값에는 잡음이 발생하고 미분기의 동적특성을 가지고 있는 HMD에 입력신호로 사용하는 경우 상당한 오차가 생기는 변위 되먹임(Feedback)의 문제점을 확인하였다. 이러한 문제점을 개선하기 위해 제진장치 입력신호의 시간간격(Time-interval)을 조정하여 오차를 줄일 수 있는 방안을 제안하였다. 수치해석결과, 입력신호에는 최적의 시간간격(Time-Interval)이 존재하였으며 이를 적용할 경우 건물의 변위와 가속도 응답을 크게 줄일 수 있음을 확인하였다.

  • PDF

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.