• Title/Summary/Keyword: 제어 정확도

Search Result 2,247, Processing Time 0.031 seconds

Characteristic of Wave Diffraction and Reflection for Irregular Waves in SWASH Model Around Small Port Structures (소규모 항만 구조물 주변에서 불규칙파에 대한 SWASH 모형의 반사 및 회절)

  • Kwon, Kyong Hwan;Park, Chang Wook;Park, Il Heum;Kim, Jong Hoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.468-477
    • /
    • 2019
  • The numerical model of Boussinesq approximation, which is mainly used for evaluating the port calmness due to the irregular waves, has a limit of applicability of lattice size in ports such as marinas with narrow port openings of around 30m. The SWASH model controls the partial reflection according to the depth, porosity coefficient and structure size when applying the reflected wave incident on the structure and terrain. In this study, the partial reflection evaluation at the front of the structure according to the bottom shape and the shape of the structure are examined. In order to evaluate the reproducibility of the model due to the diffraction waves entering the term, the area of incidence at right angles and inclination of the structure is constructed and compared with the diffraction theory suggested by Goda et al. (1978). The experimental results of the sectional structure reflectances calculated as the depth mean show reflectances similar to the approximate values of the reflectances presented by Stelling and Ahrens (1981). It is considered that the reflected wave is well reproduced according to the control of the reflected wave at the boundary and the shape and topography of the structure. Compared with previous studies to examine the diffraction of the wave incident from the breakwater opening, the wave incidence angle and the shape of the diffraction wave are very similar to the theoretical values, but both oblique and rectangular incidence In the case where the direction concentration is small, the diffraction degree is underestimated in some sections with the crest ratio of 0.5 to 0.6.

Utilization of Smart Farms in Open-field Agriculture Based on Digital Twin (디지털 트윈 기반 노지스마트팜 활용방안)

  • Kim, Sukgu
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2023.04a
    • /
    • pp.7-7
    • /
    • 2023
  • Currently, the main technologies of various fourth industries are big data, the Internet of Things, artificial intelligence, blockchain, mixed reality (MR), and drones. In particular, "digital twin," which has recently become a global technological trend, is a concept of a virtual model that is expressed equally in physical objects and computers. By creating and simulating a Digital twin of software-virtualized assets instead of real physical assets, accurate information about the characteristics of real farming (current state, agricultural productivity, agricultural work scenarios, etc.) can be obtained. This study aims to streamline agricultural work through automatic water management, remote growth forecasting, drone control, and pest forecasting through the operation of an integrated control system by constructing digital twin data on the main production area of the nojinot industry and designing and building a smart farm complex. In addition, it aims to distribute digital environmental control agriculture in Korea that can reduce labor and improve crop productivity by minimizing environmental load through the use of appropriate amounts of fertilizers and pesticides through big data analysis. These open-field agricultural technologies can reduce labor through digital farming and cultivation management, optimize water use and prevent soil pollution in preparation for climate change, and quantitative growth management of open-field crops by securing digital data for the national cultivation environment. It is also a way to directly implement carbon-neutral RED++ activities by improving agricultural productivity. The analysis and prediction of growth status through the acquisition of the acquired high-precision and high-definition image-based crop growth data are very effective in digital farming work management. The Southern Crop Department of the National Institute of Food Science conducted research and development on various types of open-field agricultural smart farms such as underground point and underground drainage. In particular, from this year, commercialization is underway in earnest through the establishment of smart farm facilities and technology distribution for agricultural technology complexes across the country. In this study, we would like to describe the case of establishing the agricultural field that combines digital twin technology and open-field agricultural smart farm technology and future utilization plans.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Hue Shift Model and Hue Correction in High Luminance Display (고휘도 디스플레이의 색상이동모델과 색 보정)

  • Lee, Tae-Hyoung;Kwon, Oh-Seol;Park, Tae-Yong;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.60-69
    • /
    • 2007
  • The human eye usually experiences a loss of color sensitivity when it is subjected to high levels of luminance, and perceives a discrepancy in color between high and normal-luminance displays, generally known as a hue shift. Accordingly, this paper models the hue-shift phenomenon and proposes a hue-correction method to provide perceptual matching between high and normal-luminance displays. The value of hue-shift is determined by perceived hue matching experiments. At first the phenomenon is observed at three lightness levels, that is, the ratio of luminance is the same between high and normal-luminance display when the perceived hue matching experiments we performed. To quantify the hue-shift phenomenon for the whole hue angle, color patches with the same lightness are first created and equally spaced inside the hue angle. These patches are then displayed one-by-one on both displays with the ratio of luminance between two displays. Next, the hue value for each patch appearing on the high-luminance display is adjusted by observers until the perceived hue for the patches on both displays appears the same visually. After obtaining the hue-shift values, these values are fit piecewise to allow shifted-hue amounts to be approximately determined for arbitrary hue values of pixels in a high-luminance display and then used for correction. Essentially, input RGB values of an image is converted to CIELAB values, and then, LCh (lightness, chroma, and hue) values are calculated to obtain the hue values for all the pixels. These hue values are shifted according to the amount calculated by the functions of the hue-shift model. Finally, the corrected CIELAB values are calculated from corrected hue values, after that, output RGB values for all pixels are estimated. For evaluation, an observer's preference test was performed with hue-shift results and Almost observers conclude that the images from hue-shift model were visually matched with images on normal luminance display.

Antioxidant Activity of Solvent Fractions from Cultivated and Wild Gromwell (재배와 야생 지치의 추출물과 용매별 분획물의 항산화효과)

  • Kim, Jin-Sook;Kang, Myung-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • In order to set up an accurate quality criteria for the Boraginaceae that have been traditionally used for medical purposes and food colorant, and to assess its viability as functional food ingredient, antioxidant tests were conducted on the wild and cultivated plants. Variety of indicators including total contents of phenol, DPPH, SOD-liked effect, hydroxy radical-scavenging effect, lecithin oxidation inhibitory effect, etc were analyzed. Wild and cultivated gromwell's total contents of phenol in their methanol extracts were 0.14% and 0.13%, while they were most active in ethyl acetate extracts and n-hexane extracts, respectively. $IC_{50}$ values of methanol extract of the wild and cultivated plants were 794.41 ${\mu}g$/mL and 971.86 ${\mu}g$/mL, indicating that the wild plant is more responsive (p<0.05) to low concentration. Also the wild and cultivated plants were most active in ethyl acetate fraction and n-hexane extracts when their $IC_{50}$ values were measured by each solvent extracts. SOD-liked effects of both plants were concentration dependent while methanol extracts were more active (p<0.05) in 500 ${\mu}g$/mL than other solvent extracts. Hydroxy radical-scavenging effect of both plants showed less than 50% activity in concentration of 1,000 ${\mu}g$/mL except in chloroform fraction and n-hexane fraction. Lecithin oxidation inhibitory effects of the wild and cultivated plants were active in methanol and solvent extracts of 200~1000 ${\mu}g$/mL. Especially it showed 90% of high inhibitory effect in 1,000 ${\mu}g$/mL of chloroform fraction. Hence, both wild and cultivated Boraginaceae were analyzed to be viable as functional food ingredient.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Occurrence of Clostridium perfringens according to Raising Periods in Broilers (육계의 사육 일령별 Clostridium perfringens 발생 분석)

  • Choe, Changyong;Park, In-Jae;Kang, Min;Jang, Hyung-Kwan;Hur, Tai-Young;Jung, Young-Hoon;Cho, Yong-Il;Do, Yoon-Jung;Yoo, Jae-Gyu;Na, Jae-Cheon;Hwangbo, Jong
    • Korean Journal of Poultry Science
    • /
    • v.40 no.4
    • /
    • pp.305-313
    • /
    • 2013
  • The objective of this study was to investigate occurrence patterns of Clostridium perfringens on different raising periods in broilers. In different raising periods, we investigated the change in the gross lesion and microscopic histological findings of the mucose of the small intestine, colony forming unit (CFU) and the types C. perfringens with PCR assay. According to the gross lesions on the mucose of small intestine with 10-days-old broilers, the non-antibiotic group showed a higher value (0.6) than the antibiotic group (0.0). Whereas 20-days-old broilers with, the antibiotic treatment had a slightly lower value (1.0) than the non-antibiotic group (1.3). In the histological examination on the villi of the small intestine, there was no damage of the villi of the small intestine with 1-day-old broilers in both groups; however, the non-antibiotic group showed a higher value (0.4) than the antibiotic group (0.0) with 10-days-old broilers. In the non-antibiotic group, the CFU of C. perfringens of the fecal samples from the small intestine increased from 10 days of raising broilers and rapidly increase after 20 and 30 days of raising broilers. There was no detection of C. perfringens types with PCR assy in 1-day-old broilers, but we found C. perfringens type A in 10-, 20- and 30-days-old broilers. Although it is possible to raise healthy broilers by using antibiotics, the addition of antibiotics to concentrate feed is prohibited for public health. The results of this study would contribute to proper feeding management through the careful use of antibiotics.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Mechanism and Spray Characteristics of a Mini-Sprinkler with Downward Spray for Prevention of Drop Water (하향 분사식 미니스프링클러의 낙수방지 메카니즘과 살수 특성)

  • Kim, Hong-Gyoo;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • A study was conducted to find mechanism and spray characteristics of a mini-sprinkler with downward spray to develop a new design type to be able to prevent drop water. The experiments were executed in a plastic greenhouse to minimize the effect of the wind. Data was collected at five different operation pressures and at 4 different raiser heights. Spray characteristics of the sprinkler such as effective radius, effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. In order to analyze the mechanism and packing supporter of sprinkler, the numerical simulation using ABAQUS was performed. The optimum pressure for preventing drop water was determined.