• Title/Summary/Keyword: 제어밸브

Search Result 896, Processing Time 0.023 seconds

Home Security System Based on IoT (IoT 기반 홈 보안 시스템)

  • Kim, Kang-Chul;Wang, Ding-Hua;Han, Seok-Bung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.147-154
    • /
    • 2017
  • This paper aims to build a home security system based on IoT to monitor a home on a mobile phone. The system consists of data gathering sensors, camera, gateway and Xively platform. The Raspberry Pi collects data from the three sensors and sends the data to Xively, and sends the video stream of home to a client in a smart phone through a internet. The servers are composed of Xively, socket server in Raspberry Pi and E-mail server in Google. The proposed system transmits e-mail, text message, and video stream when there are motion, fire, and gas leakage, and can control the gas valve through Raspberry Pi. The experimental results show that a user gets 'emergency E-mail' and text message and watches the video stream of the home through WIFI or LTE on a smart phone.

Thermodynamic Analysis on Hybrid Molten Carbonate Fuel Cell - Turbo Expander System for Natural Gas Pressure Regulation (용융탄산염연료전지와 터보팽창기를 이용한 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • In the natural gas pressure regulation station, high pressure natural gas is decompressing using pressure regulation valves. Waste pressure occurred in the pressure regulation process can be recovered through adopting turbo expanders. However, in the waste pressure recovery process, Joule Thompson effect causes below $0^{\circ}C$ and this low temperature freezes outside land of pipeline or generates methane hydrate in the pipeline which can block the pipeline. Therefore, turbo expander systems are accompanying with a boiler for preheating natural gas. Molten carbonate fuel cell (MCFC), one of the high temperature fuel cell, can use natural gas as a direct fuel and is also exhausting low emission gas and generating electricity. In this paper, a thermodynamic analysis on the hybrid MCFC-turbo expander system is conducted. The fuel cell system is analyzed for the base load of the hybrid system.

The effect on corrosion resistance of actuator system plated with Cr+6 free chemical conversion solution for ocean plant. (내해수용 Actuator system의 내식성에 미치는 Cr+6 free 화성피막 용액적용 효과)

  • Park, Jeong-Hwan;Kim, Tae-Won;Jo, Dae-Hyeong;Kim, Jeong-Su;Han, Su-Min;Jeong, Dae-Hui;Jeon, Gyu-Seong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.105-105
    • /
    • 2017
  • actuator system은 조선, 제철, 석유화학 및 중공업 등 다양한 분야에서 각종 유량 및 공기압 등을 제어하는 밸브에 필수적으로 사용되는 핵심 부픔이다. 최근 유정 개발 등 해양구조물 설치 조절이 복잡화 되면서 본 부품이 해양산업에 사용되는 빈도가 증가하고 있다. 이 경우 본 부품이 염분이 많은 바닷물 또는 주변 환경에 직접 노출되기 때문에 내식성이 매우 엄격하게 관리되고 있다. 본 부품에 부식이 발생할 경우 control system의 작동을 지배하는 구성 품에 부식이 발생하여 actuator로서 기능을 상실하여 오동작이나 설비 가동이 중단되는 사례가 빈번하다. 현재 본 부품의 내식성 향상을 위해서는 금속기 표면에 페인트를 사용하는 방법이 가장 널리 사용되고 있는 방법이다. 이 경우 금속 표면과 도장 면과의 사이에 기포발생이나 이물질 유입 등으로 인한 밀착성이 감소되거나 blister 등으로 인하여 도장 코팅 면이 박리되는 사례가 빈번하다. 이를 방지하기 위해서 최근 고 밀착성 내식용 도장 방법을 적용하고 있으나, 이 방법으로 도장한 부품의 표면에 충격 등으로 인한 결함이 발생할 경우 pitting corrosion 등 급격한 부식이 발생하여 이에 대한 근본족인 대책 수립이 절실한 실정이다. 본 연구에서는 근본적으로 금속기 표면과 밀착성이 우수한 화성피막 용액을 이용하여 희생양극에 의한 내식성을 확보하고, 다양한 용도에 적합한 색상 도료를 화성피말 위에 적용하여 화성피막 층의 보호 및 actuator의 목적에 맞는 도장을 하였다. 희생 양극효과를 극대화 할 수 있는 최적 화성피막 층은 $15{\mu}m$이며 이때 1,000시간 이상의 내식성을 확보하였다. 이 경우 이론적인 내식 수명은 2년으로 추정할 수 있었다.

  • PDF

A Study on Dynamic Characteristics of Directional Control Logic Valve (방향제어 조직밸브의 동특성에 관한 연구)

  • Lee, Il-Yeong;Oh, Se-Kyung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.4
    • /
    • pp.172-179
    • /
    • 1988
  • A cartridge type hydraulic logic valve consists of simple two port valve whose poppet is closed or opened by means of pressure signal of a pilot line. Accordingly, the logic valve can be used not only for direction, flow and pressure control purpose but also for versatile function valve which enables all above mentioned functions. In addition, the valve has little internal leakage and pressure loss, superior response characteristics and easiness in making small block type valve. The above mentioned good performances being recognized recently, the logic valve has been used widely in the large scale hydraulic system such as a hydraulic press system, for the performance requirements of high speed operation and precise control characteristics. However, there are scarce reports until now, except for a few ones from Aachen Institute of Technology in West Germany, so it is necessary to be studied on development and investigation for practical application. This paper showed that the static and dynamic characteristics of a logic valve when the logic valve is used for directional control, to investigate the relations between the valve operating characteristics and the valve design conditions. From the above mentioned procedure, it was ascertained that the valve operation characteristics obtained by numerical analysis showed good agreements with experimental results. The representative results obtained are as follows; 1. During the valve is closing, the poppet velocity is almost constant in the logic valve. 2. The pilot pressure P sub(3) and the resistance R in the pilot line have much influences on the valve operation time. 3. Spring strength have not such a severe influence on the valve operating time. 4. The operation characteristics of the logic valve can be estimated with good accuracy comparatively by numerical analysis with the equations describing poppet motion.

  • PDF

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

Development of the Low Pressure Piping System for the Liquid Rocket LOX Feed System (액체로켓 LOX 공급계의 저압 배관시스템 개발)

  • Jun, Sang-In;Jung, Jin-Taeg;Kim, Woo-Kyum;Park, Joon-Seong;Kwon, Oh-Sung;Kim, Young-Mog
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.322-325
    • /
    • 2007
  • This paper shows the development procedure of the low pressure LOX feed system which is used in the liquid rocket with a turbopump. Korean Air has cooperated with KARI in developing the LOX feed system to turbopump. The LOX feed system is characterized with cryogenic temperature and the thin-thickness tube for weight saving. The system in this project is composed with a main feed line and a recirculation line for the LOX temperature conditioning. Each piping system has many components, namely, bellows, filter, orifice, valves, flange and support. In this paper, system design & manufacturing, structural & thermal analyses, and component tests are explained. Finally, the system was assembled to the KARI's PTF test facility and functioned well to meet its required performance.

  • PDF

Pressure Recovery in a supersonic ejector of a high altitude testing chamber (초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.833-837
    • /
    • 2010
  • This study aims at finding an optimal exhaust diffuser design of a high altitude testing chamber for a low bypass turbofan engine (F404-402) with thrust pound force of 17,700 and air mass flow rate of 66kg/s ejecting at a speed of Mach 1.66. The final proposed ejector size has better pressure recovery characteristics and targets to reduce operational cost at engine performance testing. Conventional high altitude test chamber layout was adopted and first drawn in two dimensions using Autocad software so as to determine the gas path, the ejector frontal size was then determined from gas dynamics equations considering traditional gas ejection method where both the engine exhaust and cell cooling air are exhausted via the ejector. Modification to a smaller ejector with an alternative secondary cell cooling exhaust port was then performed and modelled in 3D using Solid Works software.

  • PDF

Evaluation of Total Loss of Feedwater Accident/Recovery Phase and Investigation of the Associated EOP (완전급수상실사고/복구과정의 평가와 관련비상운전절차의 검토)

  • Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.37-50
    • /
    • 1993
  • To evaluate the sequence of event and the Thermohydraulic behavior during total loss of feedwater accident and recovery procedure, a RELAP5/MOD3 calculation is performed and compared with the LOFT L9-l/L3-3 experiment. Also, the predictability of the code for the major Thermohydraulic phenomena following the accident is assessed. As a result, it is found that a pressure control using the spray until the time the water level reaches the top of the pressurizer, an overpressure protection by pressurizer PORV, a recovery of the secondary heat removal capability by refilling steam generator, and an effective cooldown by the continued natural circulation can be performed without core uncovery. It is also found that the plant-specific evaluation is necessary to confirm the effectiveness of the current symptom-oriented emergency operating procedure, especially in an overpressure protection performance and steam generator recovery performance.

  • PDF

Development of the Connection Unit with a Gas Gun Installed in a Quadcopter-type Drone (쿼드콥터형 드론에 설치된 가스총 결합유닛의 개발)

  • Jeon, Junha;Kang, Ki-Jun;Kwon, Hyun-Jin;Chang, Se-Myong;Jeong, Jae-Bok;Baek, Jae-Gu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.774-781
    • /
    • 2018
  • In this investigation, a gas gun is proposed driven by carbon dioxide gas and installed on a quadcopter-type small unmanned drone for the purpose of cattle vaccination, and we developed a launcher and its connection unit. The system consists of a commercial drone, a gas gun, a solenoid valve, and the remote communication controller, etc. The velocity of launched projectile is measured, and the full system is finally validated through ground test and flight examination loaded for the real aircraft. The feasibility is checked if this technology is applicable to various disease abatement and hazard mitigation in the fields of agriculture and fire-fighting with the present research and development.

Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve (핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2189-2194
    • /
    • 2009
  • The automatic hot gas by-pass technique is applied to control the capacity of refrigeration and air-conditioning system when operating at part load. In the scheme, the hot gas from the compressor is extracted and injected into the outlet of an evaporator through a hot gas by-pass valve. Thus, In this paper, the hot gas by-pass scheme for CO2 is discussed and analyzed on the basis of mass and energy conservation law. A comparative study of the schemes is performed in terms of the coefficiency of performance (COP) and cooling capacity. The operating parameters considered in this study include compressor efficiency, superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : the superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.