• 제목/요약/키워드: 제습

검색결과 297건 처리시간 0.019초

제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구 (An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification)

  • 이상엽;황석호;김가현;이승복
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

로터리 제습기의 단순 해석 모델 개발-I. 지배방정식의 근사적 해석 (Development of a Simple Analytical Model for Desiccant Wheels-I. Approximate Solution of the Governing Equations)

  • 김동선;최영돈;이대영
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.821-827
    • /
    • 2011
  • A simple analytical model has been developed from the approximate solution of the governing equations for desiccant wheels. The model has been compared with a numerical twodimensional transient model and found capable of making realistic prediction. The analytical model will be further developed to provide simple effectiveness correlations which can be useful for the rough design or long-term simulation of the desiccant wheels in DEC systems.

로터리 제습기의 일반 해석 모델 (Development of a General Analytical Model for Desiccant Wheels)

  • 김동선;이대영
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.109-118
    • /
    • 2013
  • The absence of a simple and general analytical model has been a problem in the design and analysis of desiccant-assisted air-conditioning systems. In this study, such an analytical model has been developed based on the approximate integral solution of the coupled transient ordinary differential equations for the heat and mass transfer processes in a desiccant wheel. It turned out that the initial conditions should be determined by the solution of four linear algebraic equations including the heat and mass transfer equations for the air flow as well as the energy and mass conservation equations for the desiccant bed. It is also shown that time-averaged exit air temperature and humidity relations could be given in terms of the heat and mass transfer effectiveness.

공압시스템 제습용 중공사막 모듈의 하우징 형태에 따른 제습효율 특성 연구 (A Study on Dehumidification Characteristics of Housing with Shape for Pneumatic System)

  • 정은아;이기윤;윤소남
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.66-71
    • /
    • 2019
  • In this study, flow analysis and dehumidification experiments were performed on hollow fiber membrane module to confirm the dehumidification characteristics for its different configurations. The CFD for the three different models was conducted using $30^{\circ}C$ temperature and 30%RH inlet humidity for quantitative analysis. Each model has different shape parameters i.e. the number of baffles. Comparison between flow analysis results and dehumidification experiment results revealed a percentage error of about 5%. The difference in relative humidity between the inlet and outlet for each model was calculated using flow analysis data. It was established that the difference in relative humidity of the inlet and outlet for the refined model with three baffles was highest among the three modeled modules of hollow fiber membrane module, i.e. around 9%.

열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구 (A Fundamental Study on the Composition for the Hybrid Dehumidification System Using Thermoelectric Device)

  • 류성룡;염호진;이현제;조현
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.618-626
    • /
    • 2018
  • In this paper, the hybrid dehumidification system using thermoelectric device is based on the idea of utilizing waste heat from the heat dissipation side of thermoelectric device as a heat source to regenerate chemical desiccant. We would like to apply this system to spaces required dehumidification due to continuous moisture generation or local high humidity in the houses. And, we want to confirm the possibility of developing the hybrid dehumidification system that combines passive dehumidification using chemical desiccant with active dehumidification using thermoelectric device.

다양한 건조방법과 감의 성숙도에 따른 반건시 품질특성 (Quality Properties of Semi-dried Persimmons with Various Drying Methods and Ripeness Degree)

  • 정경미;송인규;조두현;추연대
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.189-194
    • /
    • 2004
  • 다양한 건조방범과 감의 성숙도에 따른 반건시의 품질을 알아보기 위해 자연건조, 열풍건조, 원적외선 건조, 제습식건조 방법과 미숙, 적숙, 과숙과를 구분하여 반건시를 제조하였다. 자연건조의 경우 건조 기간 중 과습때문에 건조대에서 떨어지거나 미생물에 의한 오염으로 발생한 손실율이 7.0%이었으나, 열풍건조 등 인공건조를 하였을때는 손실율이 0.0%였다. 건조소요일은 자연건조 17∼18일, 원적외선건조 6∼7일, 열풍과 제습식 건조 7∼8일 소요되어 자연건조에 비해 11∼12일 정도 건조일수를 단축시킬 수 있었다. 반건시 과육부의 수분함량이 전체의 수분함량 변화에 비해 다소 완만하게 진행되었고 건조완료 시점에서 자연건조와 제습식 건조구의 수분함량이 비슷하였다. 건조가 완료될 때까지 반건시의 표피부 경도는 제습식 건조 130.3, 자연건조 107.1g/$\textrm{cm}^2$로 가장 낮았으며 조직감과 저작감이 우수하였다. 반건시의 전체 기호도에서는 제습식 건조 3.9, 자연건조 3.4 로 가장 우수하였다. 감의 숙도별 반건시 품질 비교 실험에서는 숙도에 관계없이 제습식 건조를 통해서 7∼8일 정도 소요되었고, 전체수분함량은 미숙과가 가장 낮았다. 미숙과의 표피부와 과심부 경도가 가장 높았고, 적숙과와 과숙과의 색도가 미숙과에 비해 우수하였으며 기호도 조사에 있어서도 미숙과에 비해 적숙과와 과숙과의기호도가 우수하였다. 고품질 반건시 생산으로 지역 특산물의 이미지를 계속유지하기 위해서는 적어도 과정부가 적황색이고 과기부가 녹황색인 적숙과 이상을 사용해야 한다.

제습의 기초 및 제습기의 국내 판매현황 (Basic concept and present condition of domestic market for dehumidifiers)

  • 문인호
    • 대한설비공학회지:설비저널
    • /
    • 제27권6호
    • /
    • pp.523-532
    • /
    • 1998
  • 우리나라의 여름철 기후는 장마라는 일정기간의 우기와 더불어 고온 다습한 특성을 가지고 있다. 다습한 환경은 주거환경에서 곰팡이 균이 번식하는데 좋은 조건이 되며, 산업환경에서는 각종 기자재 및 원자재를 부식시키고, 일부 작업 공정을 어렵게 하는 문제점을 유발한다. 반면, 온도는 높지만, 습도가 낮은 중동 사막지역의 경우는 수 천년 동안 미이라가 훌륭하게 보존되어 왔다. 따라서 상대적으로 고습 기후 조건을 갖는 지역은 저습 기후 지역에 비하여 더 큰 습도제거 대책이 필요하게 되는 불리함이 있다.

  • PDF