• Title/Summary/Keyword: 제방설계

Search Result 210, Processing Time 0.03 seconds

2-Dimensional Equilibrium Analysis and Stability Analysis of Geotextile Tube by Hydraulic Model Test (지오텍스타일 튜브의 2차원 평형해석 및 수리모형시험을 통한 안전성 분석)

  • 신은철;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.251-260
    • /
    • 2002
  • Geotextile tribes are made of sewn geotextile sheet and hydraulically or mechanically filled with dredged materials. They have been applied in hydraulic and coastal engineering in recent years(shore protection structure, detached breakwater, groins, and jetty). Therefore, it is composed of geotextile and confined fill material. Recently, new preliminary design criteria supported by model and prototype tests, and some stability analysis calculations have been studied. The stability analysis of geotextile tube is composed of geotechnical and hydrodynamic analysis. The stability check points are sliding failure, overturning, bearing capacity failure against the wave attack. In this paper are presented the stability analysis method by empirical equation and 2-D equilibrium analysis for geotextile tube. Also, the hydraulic model tests were performed to verify the theoretical stability analysis with geotextile tube shape, filling ratio, significant wave height, and so on. The results of this study show that the stability of geotextile tube depends on the tube shape, contact area, projection area. The theoretical analysis and hydraulic model test show almost the same results.

Experimental Study of Collapse Delay Effect of Riprap on Dam Slope (사력댐 사석 보호공의 붕괴 지연 효과에 대한 실험 연구)

  • Jeong, Seokil;Kim, Seung Wook;Kim, Hong Taek;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • The 99.1% of small dam and most of the levees in Korea are soil dam which can be constructed with lower cost and less effort compared with ones made of concrete. However, they are so vulnerable to overflow. Sudden collapses of these strucrues lead to increase flow rate rapidly, which may cause catastrophic problems in downstream regions. In this study, the experimental study on the collapse delay effect of riprap that was laid on slope of soil levee was carried out. A prismatic rectangular open channel was used and three different sizes of the riprap were installed on slope of a scaled earth dam. A new formula for the collapse time of the levee with the installation of riprap was presented, using the previous researches and the dimensional analysis. In this process, an unsteady flow condition was considered to derive the deviation time of the riprap. And additional experiments were conducted to understand the effect of reinforcement of riprap, and it was found that the reinforcement of riprap was more effective than twice sizing of intial riprap. If the collapse time is delayed, EAP (Emergency Action Plan) and forecasting can greatly reduce the degree of flood damage. Also, it will be meaningful that the results of this study are used for river design.

Evaluation of Hydraulic Stability Using Real Scale Experimental on Porous Concrete Revetment Block (다공성콘크리트 호안블록의 실규모 실험을 통한 수리안정성 평가)

  • Kim, Bong-Kyun;Seo, Dae-Seuk;Park, Jun-Seok;Kim, Yun-Yung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.122-130
    • /
    • 2016
  • The past few decades of industrialization enabled human-centered stream developments, which in turn resulted in constructing straight or covered streams, which are used only for sewage disposal purpose. However, these types of streams have become the cause of flood damages such as localized heavy rain. In response, various construction methods have been implemented to prevent stream and embankment damages. However, regulations regarding these measures only lay out minimum standards such as the height of slopes and the minimum angle of inclination. Moreover, examination of tractive force, the most crucial factor in preventing flood damage, is nonexistent. Therefore, this study evaluates various tractive forces by implementing a porous concrete tetrapod at a full scale artificial stream for experiment, controlling the rate of inflow, and measuring the velocity and depth of the stream under different experiment conditions. The test results of the compressive strength, and porosity and density of rock of the porous concrete tetrapod was between 16.6 and 23.2 MPa, and the actual measurement of air void was 10.1%, thus satisfying domestic standard. The result of tractive force experiment showed a limiting tractive force of $47.202N/m^2$, not satisfying the tractive force scope of $67N/m^2$ the stream design working expertise proposes. However, there was neither damage nor loss of blocks and hardpan. Based on previous researches, it can be expected that there will be resistance against a stronger tractive force. Therefore, it is necessary to conduct another experiment on practical limiting tractive force by adjusting some experimental conditions.

Problems and Improvement Plans of River-Crossing Structures (하천횡단구조물의 문제점과 개선방안)

  • Kim, Ki Heung;Jung, Hye Ryeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.568-572
    • /
    • 2015
  • 하천횡단구조물은 하천을 횡단하는 시설물로, 크게 농업용수 취수용 보, 하도개수시 유속제어를 위한 낙차공 등을 들 수 있으며, 각각의 설치목적에 따라 그 형태와 설계제원(높이, 마루폭, 바닥보호공의 길이 등)이 다르나, 하천을 횡단하여 인공적인 구조물을 설치하는 형태는 동일하다. 따라서, 하천횡단구조물은 홍수시 배수위 영향으로 상류에 수위상승을 초래하여 하천의 치수 안전도를 저하시킬 뿐 아니라 직하류에서는 하상의 세굴에 의하여 호안 및 제방이 파괴되는 경우도 빈번하게 발생하고 있다. 또한, 하천횡단구조물은 생태계의 이동통로로서의 종적 연속성을 차단하는 것이다. 즉 하천을 따라 거슬러 올라가는 소하성 어종(anadromous species)이나 하천에서 바다로 내려가는 강하성 어종(catadromous species)과 같은 회유성 어종의 이동을 차단하기도 하며, 회유성 어종 이외에도 치어와 성어의 성장환경이 다른 어종의 경우는 상 중 하류를 옮겨가며 성장하는 어종의 이동도 차단하고 있다. 하천횡단구조물은 치 이수적 측면에서 반드시 필요한 하천구조물로서 치수, 생태 및 경관의 측면에서 여러 가지 문제점을 가지고 있으나 지금까지는 어도설치나 기능을 상실한 보의 철거 등 소극적인 수준에 머무르고 있기에 적극적인 개선대책이 필요한 실정이다. 따라서, 하천횡단구조물로 인한 문제점을 파악하기 위하여 경남의 20개 시 군 684개의 지방 하천에 설치된 7,725개의 하천횡단구조물에 대한 전수조사를 실시하고, 구조형식, 높이, 재료, 어도 설치 여부, 세굴현황 등을 분석하였다. 하천횡단구조물의 용도별 구성비는 보가 49%, 낙차공이 51%로 나타났으며, 구조형식은 콘크리트 구조가 72%, 콘크리트 석재 구조가 25%, 석재 구조가 3%인 것으로 분석되었다. 또한, 하천횡단구조물의 본체 높이별 구성비는 0.5m 이하가 14%, 0.5~1.0m가 35%, 1.0~1.5m가 34%, 1.5~2.0m가 10%, 2.0m 이상이 7%인 것으로 조사되었다. 어도 설치는 약 9%인 669개소에 설치되어 있었으나 대부분이 어류 등의 이용하는 생태통로 기능을 발휘할 수 없는 것으로 분석되었다. 따라서, 이러한 문제점을 해결하기 위해서 하폭, 하상고, 하상경사, 굴입정도, 유사량 등의 하도특성 및 용수이용 여건 등을 고려하여 유공관을 이용한 지하보, 석재 아치의 원리를 이용한 계단식 자연형 보/낙차공, 부분 램프 설치, 거석 놓기 등의 개선방안을 제안하였다. 제안된 개선방안은 하천복원 및 하천개수 사업 시행시에 반영하여 합리적인 하천복원 및 관리에 활용될 수 있을 것이다.

  • PDF

Study of the Saemangeum District Flood Level after Completion of Saemangeum Master Plan (새만금종합개발계획 완료 후 새만금 지구 홍수위 검토)

  • Jeong, Seok Il;Ryu, Kwang Hyun;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.248-248
    • /
    • 2018
  • 새만금 종합개발계획(정부, 2011)에 따른 내부개발의 완료시점은 2030년이며, 방수제 공사와 준설 등과 같이 만경강 및 동진강 유역 내 흐름을 변화시킬 수 있는 공사를 포함하고 있으므로 현재와 2030년의 하천 및 호의 수리특성은 다를 것이라 예상된다. 2030년까지 준설상황 등을 예측하여 반영하는 것은 사실상 불가능하기 때문에 새만금 종합개발계획에서 제시하고 있는 내부개발의 완료시점을 기준으로 홍수사상을 모의하였다. 새만금 호의 물리적인 변화는 수리특성의 변화로 이어질 수 있으며, 이는 상류지역으로 전파가 될 수 있으므로 호내 뿐만 아니라 만경강과 동진강 전역에 대한 홍수시의 수리특성을 검토하였다. 새만금 호와 연결된 만경강과 동진강의 설계홍수량은 대부분의 구간에서 100년 빈도이기 때문에 본 연구에서는 100년 빈도 홍수사상에 대한 분석을 기초로 홍수위 검토를 수행하였고, RCP8.5 시나리오를 적용한 100년 빈도 홍수량과 500년 빈도 홍수량에 대한 추가적인 연구를 수행하였으며, 이 결과를 토대로 취약지구 분석 및 대책 등을 제시하였다. 수치모의는 Delft3D를 이용하였으며, 새만금 유역의 동진강 지구의 실측치와 비교함으로써 모델의 적용성을 검증하였다. 서해안 조위 특성상 새만금 방조제는 조위 영향이 크므로, 이에 본 연구에서는 외조위의 특성을 고려하기 위해 새만금 유역 주변의 12개 조화상수(tidal harmonic constant)를 이용하여 조위에 대한 모의를 별도로 수행하고, 이 결과를 배수갑문의 경계조건으로 이용하였다. 상류 경계조건은 하천기본계획상에 제시된 하천은 이를 이용하였으며, 그 외의 소하천은 유역면적을 이용한 계산법을 사용하여, 선형적 면적 비유량(Specific Discharge, SD) 방법을 적용하여 본류의 유량에 부가하는 방식으로 수행하였다. 수치해석 결과, 준설 구간의 수위는 전반적으로 저하되었으며, 거리에 따른 수면의 경사를 분석한 결과 기존의 하천구역이 준설 등으로 인하여 호수의 특성으로 변화된 것으로 확인하였다. 본 연구에서 취약지구는 홍수위가 제방고의 약 80% 이상 되는 지역으로 결정하였으며, 이를 토대로 취약지구 분석을 수행한 결과 기존 100년 빈도에서 1지점, RCP 8.5 시나리오가 적용된 100년 빈도에서 88지점, 500년 빈도에서 125지점이 잠재적인 치수 위험이 있는 것으로 파악되었다. 기존의 1차원 연구결과와는 차이가 있는 부분은, 다수의 취약지구가 만곡부 또는 합류부 인근에 위치한 것이다. 향후 이러한 상대적인 치수 취약지점에 대해 정밀하고 국부적인 연구를 수행하여 정확한 홍수위 예측을 수행해야 할 것이다.

  • PDF

A Study on the Site Selection Method for the Creation of a Flood Buffer Section Considering the Nature-based Solution - Case Study from Upstream of Daecheong Dam to Downstream of Yongdam Dam (자연성기반기술의 홍수완충구간 조성을 위한 입지 선정 방법에 관한 연구 - 대청댐 상류부터 용담댐 하류구간 사례 연구)

  • Ji, Un;Jang, Eun-kyung;Bae, Inhyeok;Ahn, Myeonghui;Bae, Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.3
    • /
    • pp.131-140
    • /
    • 2022
  • The magnitude and frequency of extreme floods are increasing owing to the effects of climate change. Therefore, multipurpose flood management techniques incorporating nature-based solutions have been introduced to mitigate the limitations of flood management and river design methods relying on existing observation data. Nature-based solutions to prepare for such extreme flooding events include ways to retreat the embankment, expand the floodplain, and reduce flood damage. To apply these technologies, adopting appropriate location selection methods based on various evaluation factors, such as flood damage reduction effects, sustainable ecological environments, river connectivity, and physical channel structure enhancements, should be prioritized. Therefore, in this study, the optimal location for implementing the multipurpose floodplain construction project was determined by selecting the location of the floodplain expansion with objectivity in the river waterfront area upstream of Daecheong Dam to downstream of Yongdam Dam. Through the final location determination, the Dongdaeje and Jeogokje sections were included in the optimal location considering both flood damage reduction and water environment improvement.

A study on environmental flow release through flood control reservoir (담양·화순 홍수조절지 환경대응용수 활용방안 연구)

  • Dong Gue Choe;Jong Duk Park;Dong Jin Kim;Seon Woong Ryu;Soo Jin Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.371-371
    • /
    • 2023
  • 담양 및 화순 홍수조절지는 홍수 시 본류에 계획방류량만 흘러가도록 제수문을 운영하고, 계획방류량을 초과하는 홍수량은 하도 및 조절지 내에 저류하여 홍수를 지체시킨 후 저류된 홍수량은 첨두홍수가 지나간 이후 방류하는 방법으로 영산강 유역의 홍수를 방어하기 위해 '12년 건설되었다. 그러나 홍수조절지는 200년 빈도의 홍수량을 저감 시키도록 설계됨에 따라 준공 이후 10년간 '20년 8월 홍수 등 3회만 홍수방어용으로 활용되었다. 영산강은 오염부하량 대비 유출량 부족 등으로 수질관리에 취약하고 하천유지용수를 공급하는 다목적댐이 없는 등 수자원 확보가 어려우므로, 비홍수기 홍수조절지에 환경대응용수를 담수 및 방류하여 영산강의 유량확보 및 수질개선 등 활용 다변화 방안을 모색하고자 한다. 이와 관련하여 '16년 및 '19년에 시범담수를 실시하였으나, 담수 수질 관리의 어려움, 방류 전후 강우 등 제한적 여건으로 인해 하류 유량증가 및 수질 개선 효과의 확인은 어려웠으며, 제방 물비침 등을 발견하여 시설 안정성 확보가 필요한 것으로 확인되었다. '21년 안정성 확보를 위한 보강 그라우팅을 시행했으며, '19년부터 '21년 2월까지 「홍수조절지를 활용한 영산강 수질개선 방안」연구용역을 실시하여, 비홍수기 활용방안을 수립하였다. '21년 4/4분기 댐과 보 등의 연계운영협의회에 '시범담수 계획' 안건 상정 및 의결을 거쳤고, '22년 3월 25~26일까지 담양 74mm, 화순 61mm 비가 내려 담양 63만m3, 화순 151만m3를 담수하고 18~19일간 저류 후 담양은 평균 3.0m3/초로 25시간 동안, 화순은 평균 5.0m3/초로 32시간 동안 하류로 방류하였다. 방류 후 담양·화순 모두 가까운 하류 수위국 수위 상승을 확인했으며, 화순의 경우 하류 수질에 일부 영향이 있음을 확인하였다. 다만, 초기유출수 배제 등을 고려하지 않아 담수의 수질이 본류보다 좋지 않았으며, 이에 따라 수질 영향의 인과관계 확인이 어려웠다. 기존 연구용역에서 제시한 비홍수기 활용방안의 검증·보완을 위한 연구용역이 '22.5월부터 '23.12월까지 진행될 예정이며, 초기유출수 배제를 위한 조건 재수립, 수질 모니터링지점 확대 등 보완된 '시범담수 계획'을 '23.3월 댐과 보 등의 연계운영협의회에 보고하였다. 연말까지 연구용역과 연계한 시범담수·방류 시행 및 모니터링·효과분석을 통해 비홍수기 홍수조절지 최적운영방안을 마련할 계획이다.

  • PDF

Case study on the lake-land combined seismic survey for underground LPG storage construction (LPG 지하저장기지 건설을 위한 수륙혼합 탄성파탐사 사례)

  • Cha Seong-Soo;Park Keun-Pil;Lee Ho-Young;Lee Hee-Il;Kim Ho-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.101-125
    • /
    • 2002
  • A lake seismic survey was carried out to investigate possible geohazards for construction of the underground LPG storage at Namyang Lake. The proposed survey site has a land-lake combined geography and furthermore water depth of the lake is shallow. Therefore, various seismic methods such as marine single channel high resolution seismic reflection survey, sonobuoy refraction survey, land refraction survey and land-lake combined refraction survey were applied. Total survey amounts are 34 line-km of high resolution lake seismic survey, 14 lines of sonobuoy refraction survey, 890 m of land refraction survey and 8 lines of land-lake combined refraction survey. During the reflection survey, there were severe water reverberations from the lake bottom obscured subsurface profiling. These strong multiple events appeared in most of the survey area except the northern and southern area near the embankment where seems to be accumulated mainly mud dominated depositions. The sonobuoy refraction profiles also showed the same Phenomena as those of reflection survey. Meanwhile the results of the land-lake combined refraction survey showed relatively better qualities. However, the land refraction survey did not so due to low velocity soil layer and electrical noise. Summarized results from the lake seismic survey are that acoustic basement with relatively flat pattern appeared 30m below water level and showed three types of bedrock such as fresh, moderately weathered and weathered type. According to the results of the combined refraction survey, a velocity distribution pattern of the lake bottom shows three types of seismic velocity zone such as >4.5 km/s, 4.5-4.0km/s and <4.0km/s. The major fault lineament in the area showed NW-SE trend which was different from the Landsat image interpretation. A drilling was confirmed estimated faults by seismic survey.

  • PDF

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF