• Title/Summary/Keyword: 제동용량

Search Result 24, Processing Time 0.02 seconds

A Study on the Engine Performance and Emission Characteristics in a LP EGR System with Electronic Throttle Control (ETC를 적용한 저압 EGR시스템의 엔진성능 및 배출가스 특성에 관한 연구)

  • Park, Jun-Heuk;Lim, Jong-Han;Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.379-387
    • /
    • 2011
  • Research and development of LP EGR system for the performance improvement and emission reduction on diesel engine is proceeding at a good pace. LP EGR system seems to be helpful method to further reduce$NO_x$ emissions while maintaining PM emissions at a low level because the boost pressure is unchanged while varying EGR rate. This study is experimentally conducted on a 2.0L common rail DI engine at the medium load condition (2000 rpm, BMEP 1.0 MPa, boost pressure 181.3 kPa) that difficult to use large amount of EGR gas because of deteriorations of performance and fuel consumption. And we investigated the characteristics of performance and fuel consumption while varying EGR systems. The overall results using LP EGR system equipped with ETC identified benefits on reduction of PM and improvement of fuel consumption and thermal efficiency while keep the $NO_x$ level compared to HP EGR and LP EGR with back pressure valve.

DC Traction Regenerative Energy Storage Devices using Super-capacitor (슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치)

  • Kim, Jong-Yoon;Jung, Doo-Yong;Jang, Su-Jin;Lee, Byoung-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Regenerative energy generated by regenerative braking of DC traction can cause the system malfunction or damage to the rectifier, or malfunction of the power conversion device in power supply system by DC Line voltage rise in feeder line. Regenerative energy storage system using super capacitor is one of the ways to stabilize DC line voltage. In this paper, energy storage system of DC traction system using super-capacitor bank is implemented and using the field measurement data of the station N and the station S on the Line 2, the operation characteristics of line voltage caused by regenerative energy of electric trains are verified. Also, charge/discharge characteristics of super capacitor are verified as well. Thus, we can verify the operation characteristics of super-capacitor bank for regenerative energy storage system installed in DC Traction. And if we can use field measurement data of DC line voltage, we have obtained cost reduction. The stabilization of the system will be improved by measuring the operation characteristics of regenerative energy storage system in certain section operated by DC traction and predicting the capacity and lifetime of super-capacitor.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Design and Construction of the Prototype of 25 kW Small Combine for Harvesting Miscellaneous Cereal Crops (잡곡 수확용 25 kW급 소형 콤바인 시작기 설계 제작)

  • Lee, Beom Seob;Ji, Keum Bae;Kim, Sung Chan;Yoo, Soo Nam
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.78-78
    • /
    • 2017
  • 현재 국내에 공급되고 있는 잡곡류 수확기는 보행형 예취기, 탈곡기 위주의 저능률 기계화 수준으로 고능률의 콤바인 수확기 개발이 필요하며, 특히 잡곡류가 소규모 경작지의 영세농가 위주로 재배되어 저가격의 소형 콤바인 수확기 개발이 절실히 요구되고 있다. 따라서 본 연구는 소규모 밭의 두류 및 잡곡 수확작업에 적응성이 뛰어나며, 농기계 임대사업소의 활용도를 높일 수 있고, 여성과 고령자도 쉽게 운전할 수 있어 수확작업의 노동력을 크게 절감할 수 있는 저가격의 25kW급 자주식 소형 콤바인을 개발하고자 시작기를 설계 제작하였다. 시작기의 주요부로 엔진은 25kW/2600rpm 3기통 디젤엔진을 탑재하였으며, 동력전달부는 주변속 3단, 부변속 2단의 선택맞물림 기어식의 변속장치를 이용하였다. 주행부는 궤도형으로 조향클러치와 습식 원판식 제동장치를 채용하였다. 전처리부는 선단거리 1700 mm의 디바이더와 상하좌우 수동 조절되는 회전속도 약 42 rpm의 정오각형 릴로 구성하였으며, 전처리부의 최대 승강높이는 740 mm이었다. 작물이송부는 돌기부착 오거와 체인컨베이어로 구성되어 있으며, 탈곡부는 단동형 축류식의 직경 440 mm, 길이 1180 mm의 급동과 높이 65 mm, 지름 10 mm의 46개 강봉형 급치, 격자형 수망으로 구성하였으며, 회전속도는 약 325 rpm으로 작동하도록 하였다. 선별 정선부는 요동 송풍선별식으로 곡립판, 볏짚체, 곡립체, 송풍팬으로 구성하였고 송풍팬의 회전속도는 약 850 rpm, 요동진동수는 약 5.8 Hz로 작동하도록 하였다. 곡물이송부와 재처리부는 수평이송 외경 103 mm, 수직이송 외경 110 mm의 피치가 모두 82 mm인 스크류컨베이어를 이용하였으며, 곡물탱크는 용량이 250 로 2개의 배출구로 곡물을 포대에 담도록 하였다. 그 외 시작기는 운전조작부, 유압장치부, 전기장치부 등을 갖도록 설계 제작하였다. 전체적인 기체의 크기는 길이${\times}$${\times}$높이 $3935{\times}1900{\times}2440mm$이었으며, 기체 중량은 약 1753 kg이었다. 콩 대상 기초 성능시험 결과 시작기의 작업속도는 약 0.5 m/s, 작업능률은 약 11 a/h로 나타났다.

  • PDF