• Title/Summary/Keyword: 제거효율평가

Search Result 1,019, Processing Time 0.027 seconds

Radiological Safety Assessment for KAERI Incineration Plant on the Basis of Trial Burn Results (시험소각결과에 기준한 한국원자력연구소 소각시설의 방사학적 안전성 평가)

  • Yang, Hee-Chul;Kim, Bong-Hwan;Kim, Chang-Hee;Park, Won-Man;Jeong, Myung-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.109-114
    • /
    • 1998
  • Radiological safety for the conventional operation of Demonstration-Scale Incineration Plant (DSIP) was assessed on the basis of the results of trial burns using the simulated and real radioactive wastes. Radiation dose assessments for routine releases on an annual basis as well a several severe accidental releases on a short-term basis (2h) revealed that there would be no significant environmental impact when low-level waste Is incinerated in DSIP. For semivolatile radioactive cesium species, expected emission concentrations slightly exceeded 10% of maximum permissible concentration. Removal characteristics of the bag filter for condensed-phase cesium species was investigated by the trial burns of simulated waste with inactive cesium tracer. In the off-gas before passing through bag filter, distributions of condensed cesium species in the transition size ranging between the diffusional and inertial region are less than 5%. The overall collection efficiency of the bag filter for cesium species was higher than 99.9%, showing enough decontamination capability as a primary filter for the low-temperature dry off-gas system in radwaste incineration plant.

  • PDF

Removal of Toxicity from Kraft Pulp Mill Effluents by Activated Sludge Process (활성슬러지 공정에 의한 Kraft 펄프 폐수의 독성 제거)

  • Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.3
    • /
    • pp.9-18
    • /
    • 1994
  • Activated sludge pilot plant testing was conducted to determine the ability of a well-designed activated sludge treatment system to remove chromic toxicity from the bleached kraft pulp mill effluent. Removals of conventional(BOD and SS) and nonconventional(resin and fatty acids, color, AOX) pollutants were estimated. The pilot plant was operated at steady state for about 10 weeks at an F/M of 0.28 and a sludge age of 8.4 days. The average MLSS concentration was 4,309mg/l, of which volatile fraction was 57%. During the operation period, the BOD removal reaction rate(k) was determined to be 8.2/day at $30^{\circ}C$. The BOD removal was 84 percent, which was 3 to 6 percent lower than expected for full-scale treatment. The chronic toxicity of the activated sludge effluent was tested by employing both Dinnel and the BML protocols. It was found that the pilot plant could achieve in excess of 90 percent reduction in chronic echinoderm toxicity. The data show slight reduction of color and AOX across the activated sludge system. The pilot system, however, demonstrated on excellent removal of resin and fatty acids.

  • PDF

Research on Improvement of Lake Water Quality Using Artificial Floating Island (호소 수질 개선을 위한 인공식물섬 장치 개발 연구)

  • Kim, Tae-Hoon;Ahn, Tae-Woong;Jung, Jae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.263-270
    • /
    • 2010
  • This is a research on development of water purification equipment called artificial floating island (=AFI) for the stagnant water area which can secure exuberant landscape and water-friendility. The equipment devised in this study is designed to make up the weakness of conventional AFIs and improves the removal efficiency of pollutants using the mixture of media and plants. The air compressor positioned at the inlet releases air with inflow continuously, the water pump at the outlet sprays as a form of fountain with causing a disturbance on stable water column, then, both of them contribute improvement of water quality over a large area. We applied Bio-stone as a media in this system and performed an experiment of pre-efficiency test, and we concluded that the higher pollutants concentration of inflow, the higher removal efficiency we obtained. At the result of lab-scale experiment, in the case of high-concentration inflow, in the removal efficiency of SS is 62.2%, BOD is 50.2%, COD is 55.1%, T-N is 31.6%, T-P is 38.4%. In addition, to evaluate the field application, we set up the facilities in Sin-gal lake located in Yongin-Si Gyeonggi-Do, and researched on the removal efficiency of outflow relative to the inflow. As a result, SS is 53.5%, BOD is 32.8%, COD is 36.9%, T-N is 22.6%, T-N is 33.2%.

A Study on the Optimal Operating Conditions for Removal of Nutrient Influential Substances Using Functional Media (기능성 여재를 활용한 부영양화 영양물질 제거의 최적 운전조건 연구)

  • Lee, Jong-Jun;Oh, Jong-Min;Choi, Seung-Jong;Kim, Ki-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.549-555
    • /
    • 2019
  • The purpose of this study is to ensure optimal operating conditions for improving the removal efficiency of phosphorus (P) and nitrogen (N) that are the causative agents of eutrophication by utilizing functional media. The main ingredients of the functional media used in this study are Si, Al, and Fe, SiO2, KAlSiO3O8, Al2O2·2SiO2O, H3Al2Si2O9, Fe3O4O), and berylite. To identify the maximum efficiency of the filtration process, the processing efficiency experiment was carried out according to flow method, velocity, and thickness of residual media. The flow method carried out two experiments, 50 m/day, 100 m/day, 150 m/day, 200 m/day, 250 m/day, and 20 cm, 40 cm, 50 cm, 60 cm, 80 cm of lead depth. Experiments have shown that SS, T-N, and T-P all showed higher elimination efficiency of the upflow current conditions than the downflow current conditions, and that the processing efficiency of the linearity is the highest at SS 50 m/day, T-N 150 m/day and T-P 100 m/day. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. It is considered desirable to set the top-down flow conditions and residual thickness of 60 cm and adjust the velocity of the line according to the target media for removal.

Assessment of Performances of Low Impact Development (LID) Facilities with Vegetation (식생이 조성된 LID 시설의 효율 평가)

  • Hong, Jung Sun;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.100-109
    • /
    • 2016
  • Low impact development (LID) facilities are established for the purpose of restoring the natural hydrologic cycle as well as the removal of pollutants from stormwater runoff. Improved efficiency of LID facilities can be obtained through the optimized interaction of their major components (i.e., plant, soil, filter media, microorganisms, etc.). Therefore, this study was performed to evaluate the performances of LID facilities in terms of runoff and pollutant reduction and also to provide an optimal maintenance method. The monitoring was conducted on four LID technologies (e.g., bioretention, small wetlands, rain garden and tree box filter). The optimal SA/CA (facility surface area / catchment area) ratio for runoff reduction greater than 40% is determined to be 1 - 5%. Since runoff reduction affects the pollutant removal efficiency in LID facilities, SA/CA ratio is derived as an important factor in designing LID facilities. The LID facilities that are found to be effective in reducing stormwater runoff are in the following order: rain garden > tree box filter > bioretention> small wetland. Meanwhile, in terms of removal of particulate matter (TSS), the effectiveness of the facilities are in the following order: rain garden > tree box filter > small wetland > bioretention; rain gardens > tree box filter > bioretention > small wetland were determined for the removal of organic matter (COD, TOC), nutrients (TN, TP) and heavy metals (Cu, Pb, Cd, Zn). These results can be used as an important material for the design of LID facilities in runoff volume and pollutant reduction.

Estimation of Water Quality Improvement and Reduction of Influent Pollution by Installation of Water Treatment System Filled with Bio-stone Ball (바이오스톤 볼 수처리 시스템에 의한 오염물질 저감 및 저수지의 수질개선효과 산정)

  • Choi, Sunhwa;Kim, Heungseop;Chung, Sewoong
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.5
    • /
    • pp.471-482
    • /
    • 2019
  • Water treatment system filled with Bio-stone Ball (BSB) have been developed for the purification of polluted water in many rivers and lakes. The real-scale plants of BSB water treatment system was constructed for field application test and water purification evaluation in Maewha reservoir. The average water purification efficiencies of BSB watertreatment system shows BOD 70.3% (47.2~97.4%), COD 45.3% (26.1~64.7%), TOC 19.2% (8.5~50.0%), SS 82.8% (73.1~92.7%), Chl-a 80.4% (57.2~91.8%), TN 23.2% (6.4~39.5%), and TP 51.8% (-1.1~80.1%). BSB water treatment system shows very high at 70~80% in the water purification efficiencies of BOD, Chl-a, and SS. The average of pollution loading reduction by installation of BSB treatment system shows 39.2% for COD and 16.8% for TP. The water quality improvement rates (%) of the Maewha reservoir shows TOC 14.5%, COD 14.5%, Chl-a 12.5% and TP 25.1%. The BSB watertreatment system can be applied to many agricultural reservoirs and major rivers to deal with serious water pollution issues.

The Evaluation of Temperature Effect on Nitrogen RemovaI at Intermittent MBR System by Computer Simulation (컴퓨터 시뮬레이션을 이용한 간헐폭기 MBR공정에서의 운전온도 변화에 따른 질소제거 성능 평가)

  • Lee, Byonghi;Park, Min-Jung
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.489-501
    • /
    • 2012
  • The nitrogen removal characteristics of the MBR system consisted of two intermittent reactors, a membrane reactor and a deaeration reactor under constant flow and wastewater composition at different operational temperature and SRTs (Sludge Retention Times) were studied by computer simulation. The nitrogen removal efficiencies were dropped from 59% to 31%, when operational temperature was increased to $25^{\circ}C$ from $13^{\circ}C$ with same SRT of 25 days. Lower RBO (Readily Biodegradable Organic) concentrations at intermittent reactors at $25^{\circ}C$ compared with those at $13^{\circ}C$ of operational temperature were believed to be the main cause. The nitrogen removal efficiencies and RBO concentrations at each intermittent reactors were recovered when SRT was reduced to 12.6 days at $25^{\circ}C$. The effect of both SRT and operational temperature on RBO concentrations at intermittent reactors is need to be studied further.

VOC 제거를 위한 상압플라즈마 발생장치 개발

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.553-553
    • /
    • 2013
  • 상압 플라즈마 기술은 표면처리, 온존 발생장치, VOC (Volatile Organic compound) 제거등 다양한 산업분야에서 응용되고 있다. 상압플라즈마 기술 또한 DBD (Dielectric barrier discharge), Griding Arc, SDIP (Surface Discharge Induced Plasma) 등 다양한 기술들이 개발되어져 왔다. VOC를 제거하기 위한 다양한 플라즈마 기술중 특히 BDB 방법과 SDIP 기술들은 플라즈마에 의한 VOC 분해 뿐만 아니라 오존 발생을 통하여 VOC성분을 분해하는 것으로 알려져 있으며 효율이 매우 뛰어난 것으로 보고 되고 있다. 그러나 BDB 방전의 경우 방전이 발생하는 간격이 매우 작아 공기를 정화시키기 위해 좁은 유로를 통하여 일정넓이를 이동하여하 하기 때문에 압력감소가 심하며 이를 개선하기위해 다단으로 설계할 경우 구조가 복잡하고 가격이 고가인 단점이 있다. 본 연구에서는 두 개의 면 전극이 마주보는 형태로 된 DBD 구조의 단점을 보완하기 위하여 빗살무늬 모양의 다층구조의 선형전극으로 구조를 변화시켜 전극에 의한 압력감소를 방지하고 효율적으로 플라즈마 및 오존을 발생시킬 수 있는 VOC제거용 상압 플라즈마 발생장치를 개발하였다. 또한 플라즈마 발생 및 오존발생량이 우수한 것으로 알려져 있는 SDIP 장치 또한 제작하여 비교 평가를 하였다. 제작된 플라즈마 발생장치는 60 Hz와 20kHz의 교류 고압파워 서플라이를 이용하여 플라즈마 발생실험을 진행하였다. 선행 연구에서는 60 Hz의 고압 파워 서플라이를 이용하여도 플라즈마 방전이 잘 된다고 보고되었는데 본 실험에서 60 Hz 파워 서플라이를 사용할 경우 15 kV 이상이 인가될 때 아주 약하게 오존이 발생하는 현상이 관찰되었으나 육안으로 구분이 될 만큼의 플라즈마 방전은 발생하지 않았다. 20kHz의 고압파워 서플라이를 사용한 경우에는 비교적 낮은 전압인 7 kV에서 방전이 관찰되었으며 분당 22 mg의 오존이 발생하였다. SDIP를 이용한 경우 플라즈마가 발생하는 조건은 SDIP의 기하학적 형상에 많이 의존하게 된다. 본 실험에 SDIP 장치는 매우 낮은 전압에서 방전을 시작하였다. 기존의 DBD와는 다르게 1.7 kV에서 플라즈마 발생하였으며 1.8 kV에서 정상적인 플라즈마 방전이 발생하였다. 이때 분당 3.1 mg의 오존이 발생하였다. 오존 발생양은 앞에 빗살형 플라즈마 방전장치에 비하여 낮은데 인가되는 전력을 고려하면 입력된 전기 에너지당 오존발생양은 비슷한 수준이였다.

  • PDF

Removal of Gaseous Styrene using a Pilot-Scale Rotating Drum Biotrickling Filter (Pilot-scale 회전식 드럼 바이오필터를 이용한 Styrene 제거)

  • Hwang, Jae-Woong;Lim, Ji-Sung;Chang, Seok-Jin;Lee, Eun-Yul;Choi, Cha-Yong;Park, Sung-Hoon
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.188-193
    • /
    • 2006
  • A new type of biofilter, a rotating drum biotrickling filter(RDBF), was developed and operated for the removal of styrene from industrial waste gas. The porous polyurethane foam sheet was used as a packing materials for the RDBF and a pure culture of Gram-positive bacterium Brevibacillus sp. SP1 was used as an inoculum. The reactor showed a short start-up period of 18 days, during which uniform biofilms were developed on the packing. During a steady operation at an incoming styrene concentration of $200ppm_v$ and a retention time of 0.5 min, a high and stable removal of styrene over 95% was observed. The maximum elimination capacity was estimated to be $125g/m^3{\cdot}hr$. The outstanding performance was attributed to an efficient gas-liquid mass transfer and the appropriate supply of nutrient solution to the biofilm microorganisms on the packing by the rotation of the drum.

Analysis of pollutant behavior in sediments in a Rain Garden through long-term monitoring (레인가든 내 장기모니터링을 통한 오염물질 거동분석)

  • Jeon, Minsu;Choi, Hyeseon;Reyes, N.J. DG.;Kim, Leehyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.339-339
    • /
    • 2020
  • 도시화로 인한 불투수면적의 증가와 기후 변화로 인한 강우패턴의 변화 자연적 물순환 체계에 악영향을 미치며. 이를 해결하기 위하여 국내에서는 도시 내 빗물관리 및 비점오염원 저감이 가능한 저영향개발(Low Impact Development, LID)를 적용하고 있다. 건기시 도로, 주차장등 차량통행 및 유동인구가 많은 지역에서는 입자상 물질들이 많이 발생되어 노면에 축적되어 있다가 강우시 강우유출수를 통해 시설로 유입된다. 이로 인해 시설 내 오염물질 및 퇴적물이 축적되어 여재 공극막힘현상 및 침투율저하의 문제가 발생되어 시설 내 효율이 감소된다. 따라서, 레인가든의 장기 모니터링을 통해 시설 내 유입되는 오염물질의 성상 분석 및 시설 내부의 퇴적물 분석을 통해 LID시설 운영의 효율성 평가를 수행하였다. 모니터링은 강우시 모니터링과 건기시 집수구역, 침강지, 시설 상부, 중부, 하부 등 총 5곳에서 채취하여 분석을 수행하였다. 모니터링은 평균 선행건기 일수는 5.46±4.7 days, 평균 강우량은 14.31±11.4 mm, 평균 강우강도는 5.33±6.7 mm/hr의 강우사상에서 모니터링을 수행하였다. 시설 내 평균 유입수농도는 TSS 98.0 ± 32.7 mg / L, COD 133.6 ± 6.3 mg / L, TN 5.77 ± 4.05 mg, TP 0.54 ± 0.03 mg / L으로 분석되었다. 유입부 내 퇴적물 종류는 Sandy Clay Loam으로 나타났으며, Cr 0.36mg / kg, Cu 5.17 mg / kg and Pb 6.04 mg / kg으로 중금속의 함유량이 높은것으로 분석되었다. 퇴적물은 침강지 및 시설 유입부에서의 입자크기는 49-113㎛ 약 60%의 퇴적물이 축적되어 제거되는 것으로 나타났다. 시설 내 침강지에서 50㎛ 이상의 입자들이 여과, 흡착 및 침전으로 인하여 40% 이상의 입자들이 제거되는 것으로 분석되었으며, 50㎛ 미만의 입자들은 시설 내 중간부, 유출부에서 제거되는 것으로 분석되었다. 침강지에서 유입수 대부분의 입자상물질들이 흡착 및 여과로 인한 제거가 이루어지기에 침강지 여재부는 넓은 표면적, 우수한 흡착능 및 여과율을 고려하여 선정하영 하며, 잦은 교체를 위하여 중량성이 낮은 우드칩 등이 적당한 것으로 사료된다.

  • PDF