• Title/Summary/Keyword: 정적 보정

Search Result 76, Processing Time 0.029 seconds

A Static Scintigraphy for Imaging Aspiration Using Semi-Solid Food (반고형식을 이용한 정적 흡인 영상법)

  • Yoon, Min-Ki;Hwang, Kyung-Hoon;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.327-331
    • /
    • 2006
  • Purpose: Aspiration scintigraphy is a procedure of nuclear imaging to evaluate aspiration and of quantifying the amount of aspirate. The ultimate goal of our study is to define the correlation between aspiration and aspiration pneumonia by aspiration scintigraphy and this is a preliminary report of its trial. Materials and methods: Ten patients with positive findings by videofluoroscopy were selected. The patients ingested semi-solid food containing Tc-99m tin colloid 92.5 MBq (2.5 mCi) and images were acquired immediately after the ingestion and 3 hrs later. A fraction of aspiration to the ingested was calculated using an equation with a decay correction. Results: Five patients were interpreted positive by aspiration scintigraphy. Four patients were positive at initial images and the fractions of aspiration were 0.11%, 0.11%, 0.81%, and 0.11%. The one patient who was shown aspirated at both images had initial 5.82% and delayed 2.26%. Conclusion: Aspiration scintigraphy enables us to localize the aspiration at any desired time of the test and to quantify its amount. Follow-up studies are warranted.

Comparison of Elastic Modulus Evaluated by Plate Load Test and Soil Stiffness Gauge Considering Strain and Ground Stiffness (변형률 및 지반강성을 고려한 평판재하시험과 흙강성측정기의 탄성계수 비교)

  • Kim, Kyu-Sun;Shin, Donghyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.10
    • /
    • pp.31-40
    • /
    • 2022
  • This study compares elastic moduli calculated using two stiffness testing methods with different strain ranges to evaluate the stress-settlement characteristics of foundation support layers. Elastic moduli were calculated by the soil stiffness gauge (SSG) in the micro-strain range and the plate load test (PLT) in the medium strain range. To apply the elastic moduli obtained by the two testing methods with different strain ranges to the design and construction of foundation soils, the correlation between each measurement value should be identified in advance. As a result of the comparative analysis of the elastic moduli calculated using the two methods in weathered soil and rock, which are representative support layers in Korea, the calculated elastic moduli differed depending on the types of soil and stress conditions. For various soil types, the static elastic modulus obtained by the PLT was reduced by 56% because of the difference in the strain level of the test compared with the dynamic elastic modulus obtained by the SSG. Therefore, the results show that it is necessary to apply corrections to the stress distribution, stress level, and dynamic effect according to the ground stiffness to effectively use the SSG instead of the PLT.

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

A Study Related to Adolescent Students' School Uniform Behavior and Attitude toward Appearance (청소년의 교복행동과 외모에 대한 태도와의 관련 연구)

  • Han, Mi-Hwa;Lee, Eun-Hee
    • Journal of Korean Home Economics Education Association
    • /
    • v.21 no.2
    • /
    • pp.23-43
    • /
    • 2009
  • This study examined the relativity between school uniform behavior(especially attitude toward school uniform, school uniform satisfaction, school uniform alteration) and attitude toward appearance in the adolescence. From November to December in 2007, 898 middle school and high school students from four schools in Jeollabuk-do Province were analyzed and the influence of relevant variables was understood to gather basic information about the fashion life in the adolescence. This study used SPSS 11.5 for Windows Program to conduct frequency analysis, factor analysis, reliability analysis, ${\chi}^2$-test, t-test, One-way ANOVA, Duncan's multiple comparison test, and Pearson's correlation. The following summarizes the findings of this study: The results of analysing the factors to the response attitude toward uniforms and attitude toward appearance and clothing attitude emerged four dimensions(fashion, symbolism, cleanliness, alternation), three dimensions(needs value conformity toward appearance). In attitude toward uniform, female students were more actively altering their uniforms than male students and middle school students were more sensitive to trends than high school students. However, high school students were more aware of the cleanliness and alteration of uniforms. Overall, most students were not very satisfied with their uniforms (design, color, texture). When students' attitude toward appearance and demographical characteristics were examined, it was found that female students were more aware of desire, value, and conformity in appearances than male students. By age, it was found that high school students were more aware than middle school students. Also, students receiving KRW 30,000 or more for monthly allowance were more aware than others who receive a lower amount between KRW 10,000 and KRW 20,000. Therefore, most students(62.1%) have experiences in altering uniforms. Especially, more female students and more high school students had such experiences. Uniform alteration is more related to attitude to appearance. In other words, students who choose to alter their uniforms are highly aware of desire, value, and conformity toward appearance. Students who are satisfied with all factors regarding attitude toward uniform, except for alteration, did not alter their uniforms that much. In addition, when the relativity between students' attitude toward appearance with uniform was considered, students that are not very satisfied with their uniforms were more aware of desire, value, and conformity toward appearance. In conclusion, it was found that students' attitude toward appearance and school uniform behavior are closely related and their interests in appearance lead to alteration of uniforms, the clothing in which they spend most time of the day. From now on, students' opinions shall be considered when selecting or designing school uniforms.

  • PDF

List-event Data Resampling for Quantitative Improvement of PET Image (PET 영상의 정량적 개선을 위한 리스트-이벤트 데이터 재추출)

  • Woo, Sang-Keun;Ju, Jung Woo;Kim, Ji Min;Kang, Joo Hyun;Lim, Sang Moo;Kim, Kyeong Min
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2012
  • Multimodal-imaging technique has been rapidly developed for improvement of diagnosis and evaluation of therapeutic effects. In despite of integrated hardware, registration accuracy was decreased due to a discrepancy between multimodal image and insufficiency of count in accordance with different acquisition method of each modality. The purpose of this study was to improve the PET image by event data resampling through analysis of data format, noise and statistical properties of small animal PET list data. Inveon PET listmode data was acquired as static data for 10 min after 60 min of 37 MBq/0.1 ml $^{18}F$-FDG injection via tail vein. Listmode data format was consist of packet containing 48 bit in which divided 8 bit header and 40 bit payload space. Realigned sinogram was generated from resampled event data of original listmode by using adjustment of LOR location, simple event magnification and nonparametric bootstrap. Sinogram was reconstructed for imaging using OSEM 2D algorithm with 16 subset and 4 iterations. Prompt coincidence was 13,940,707 count measured from PET data header and 13,936,687 count measured from analysis of list-event data. In simple event magnification of PET data, maximum was improved from 1.336 to 1.743, but noise was also increased. Resampling efficiency of PET data was assessed from de-noised and improved image by shift operation of payload value of sequential packet. Bootstrap resampling technique provides the PET image which noise and statistical properties was improved. List-event data resampling method would be aid to improve registration accuracy and early diagnosis efficiency.