• 제목/요약/키워드: 정영준

검색결과 137건 처리시간 0.022초

단일약국과 다약국 프로그램에서 수행한 지역약국 필수실무실습에 대한 평가 (Evaluation of the Pharmacy Student Practice Programs in the Mono Community Pharmacy and Multiple Community Pharmacies)

  • 이민철;조민휘;정영준;이지영;윤현옥
    • 한국임상약학회지
    • /
    • 제24권4호
    • /
    • pp.296-303
    • /
    • 2014
  • Background: The first pharmacy student practice undergoing 6 year pharmacy school curriculum have begun in the hospital pharmacy, community pharmacy, pharmaceutical company and administrative office since 2013. Although most of practice sites have prepared the program of pharmacy student practice education for several years under guideline of Korean Association of Pharmacy Education, generally community pharmacies which start the pharmacy student practice education have difficulty in performing the desirable student practice program due to absent experience for it. So we reported the comparison of student practice programs between mono pharmacy and multiple pharmacies conducted by Gyeongsang National University College of Pharmacy to provide the future design information of the ideal pharmacy student practice in community pharmacy. Method: Students who practiced both multiple (multi) and mono pharmacy (mono) programs for each 5 weeks were participated the survey to evaluate the student practice programs. Results: The results of the survey on the student practice program reported that students were much more satisfied with the multiple pharmacies program than mono pharmacy program in both practical contents ($4.12{\pm}0.72$ : $3.27{\pm}1.28$; multi : mono) and satisfaction ($4.54{\pm}0.54$ : $3.54{\pm}1.3$; multi : mono) and they all gave the highest points ($5.00{\pm}0.00$) to multiple pharmacies program for recommendation because the multiple pharmacies program was significantly helpful for their experience to plan the future career. Conclusion: Mono and multiple pharmacy practice programs would be a great helpful for student's future career. However, the disadvantages of each program should be amended gradually for the unified and specialized program to be established the ideal community pharmacy student practice in Korea. The results will be affected the pharmacy practice program for students in community pharmacy and the other colleges of pharmacy to design the ideal community pharmacy practice program.

트라우즐 연주시험 및 고속 3차원 이미지영상상관 기법을 이용한 전색재 별 발파효과에 대한 연구 (The Study on Blast Effects of Stemming Materials by Trauzl Lead Block Test and High Speed 3D-DIC Systems)

  • 고영훈;서승환;김식;정영준;정문경
    • 한국지반공학회논문집
    • /
    • 제37권10호
    • /
    • pp.13-25
    • /
    • 2021
  • 트라우즐 연주시험은 화약의 발파성능을 검증하기 위해서 널리 사용되는 시험방법 중 하나이다. 위력이 검증된 폭약을 연주블록의 발파공에 장약 및 전색하여 폭발시킨 후 발파공의 체적변화를 통해 화약의 위력 또는 전색효과 등을 측정하는 방법이라 할 수 있다. 본 연구에서는 발파 시 전색물에 따른 전색효과를 서로 비교하기 위하여 트라우즐 연주시험 및 3차원 고속카메라를 이용한 이미지영상상관기법을 도입하여 발파실험을 수행하였다. 실험에 사용된 폭약은 산업용 에멀젼 폭약을 적용하였고, 전색재료는 모래 및 잔골재를 사용하였다. 트라우즐 연주시험 및 수치해석을 통한 비교에서 표준사보다 잔골재 전색의 경우가 연주블록의 확장이 크게 나타났으며, 3D-DIC 시스템에서도 잔골재 전색의 경우가 모래전색보다 직경변화와 표면변형률 모두 높은 수치를 보였다.

덕트맵을 이용한 제주해안지역 이상 전파특성 분석 (Analysis of Abnormal Path Loss in Jeju Coastal Area Using Duct Map)

  • 왕성식;임태흥;정영준;고민호;박용배;추호성
    • 한국전자파학회논문지
    • /
    • 제30권3호
    • /
    • pp.223-228
    • /
    • 2019
  • 본 논문에서는 국내 해안지역인 제주도-진도에서의 실제 기상데이터와 지형정보를 이용하여 각 대기 굴절 기울기에 따른 전파 경로손실을 분석하고, 실측결과와 비교하여 결과가 유사함을 확인하였다. 시뮬레이션 결과를 토대로 하여 트랩의 위치와 두께에 따라 덕트맵을 구성하고, 송 수신 안테나의 고도에 따라 영역을 분할하여, 제주 해안지역에서 자주 발생하는 덕트에 대해 분석을 진행하였다. 이러한 덕트맵의 유효성을 확인하기 위해 실제 2018년 5월의 기상데이터 중 대표적인 2개 날짜의 데이터를 선택하여 덕트맵 상에서 해당되는 위치를 확인하고, 전파 경로손실을 계산한 후, 실측데이터와 비교하였다. 시뮬레이션을 통해 얻어진 경로손실 값은 각각 167.7 dB, 192.3 dB로서 측정 결과 164.4 dB, 194.9 dB와 유사함을 확인할 수 있다.

CCM용융에 대한 유리용융 조건 연구 (The Study on the Power Consumption for Glass Melting by Cold Crucible Melter)

  • 진현주;이규호;장영재;배소영;김태호;정영준;김영석;이강택;류봉기
    • 대한금속재료학회지
    • /
    • 제46권2호
    • /
    • pp.65-68
    • /
    • 2008
  • Generally CCM (cold crucible melting) is not suitable for melting glass. However, in this study we described the quantitative relationship between the basic property of glass and power balance, the power absorption in the melt, the losses in the coil and the cold crucible, for melting glass in CCM. The dependence of power balance on the applied frequency and the electric conductivity has been found. Above 300 kHz, the glass (B) contained alkali ion which has the low resistance $3.0{\Omega}{\cdot}cm$ at $900^{\circ}C$ and $1.36{\Omega}{\cdot}cm$ at $1,100^{\circ}C$ was melted easily and 60% of the overall power was absorbed in the melt and 30% and 10% of the overall power was lost in the cold crucible and coil respectively. Under the same condition, the glass (A) contained non-alkali ion was not melted easily and 50% of the overall power was absorbed in the melt and 40% and 10% of the overall power was lost in the cold crucible and coil respectively. In conclusion, the small absorbed power of the overall power in melt prevented a successful melting as for glass A, and the successful melting depends on the relative size of the absorbed power in melt irrespective of the melting volume. Hence, as typical for direct induction heating method(CCM), the successful melting strongly depended on the chosen working frequency based on electric conductivity of glass, power balance and the control of the critical power which was absorbed in melt.

고속충격 반응형 스마트유체 전색재료를 적용한 실 규모 발파실험 및 현장실증 연구 (Full-Scale Blasting Experiment and Field Verification Research Using Shock-Reactive Smart Fluid Stemming Materials)

  • 고영훈;서승환;정영준;노상림;조상호;정문경
    • 화약ㆍ발파
    • /
    • 제41권1호
    • /
    • pp.1-18
    • /
    • 2023
  • 전색작업은 발파공 내에서 폭발가스가 쉽게 유출되지 않게 적용되는 중요한 과정이다. 전색물질은 폭발 에너지를 더 길게 공 내부에서 작용할 수 있게 하며, 암석의 파쇄도를 증가시키는데 큰 도움이 된다. 본 연구에서는 동적 충격에 반응하는 전단농화유체 기반의 전색물질을 개발하였다. 전단농화유체 기반의 전색재료의 성능을 검증하기 위해 실 규모 발파실험 및 터널현장에 대한 현장 실증을 수행하였다. 첫 번째 실험에서는 전색재료 적용에 따른 발파공 내부의 압력을 직접 측정하였고, 도심지 터널현장 실증에서는 모래전색과 전단농화유체 기반 전색재료의 발파결과를 서로 비교하였다. 발파공 내 압력측정 결과 본 연구를 통해 개발한 전색물질을 적용한 경우, 발파공 상부에서 측정된 압력이 일반적인 모래전색을 적용한 경우보다 낮았으며 폭발가스 분출량도 적었다. 또한 현장 실증결과 터널발파에서 개발전색물질의 굴착성능이 모래전색 발파의 경우보다 우수함을 검증할 수 있었다.

시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향 (Influence of varying cement types and abutment heights on pull-off force of zirconia restorations)

  • 정영준;김유리;정지혜;강내운;공현준
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.64-71
    • /
    • 2024
  • 목적: 본 연구의 목적은 세 가지 높이를 가진 티타늄 베이스 임플란트 지대주에서 세 종류의 시멘트가 지르코니아 수복물에서 가지는 제거력을 비교하는 것이다. 연구 재료 및 방법:. 90개의 직경 4.0 mm 임플란트 아날로그가 레진 블록에 식립되었다. 이후 3 mm, 5 mm, 7 mm의 높이를 가지도록 임플란트 지대주를 30개씩 제작하였고, 각 지대주를 스캔하여 지르코니아 수복물 시편을 제작하였다. 임시 시멘트(TB), 반영구 시멘트(CI), 영구 시멘트(FC)를 각자 제조사의 지시에 따라 지대주에 접착하였다. 제작된 90개의 시편은 만능시험기에서 제거력을 시험하였으며, 모든 제거력은 부하량이 하락하기 직전 가장 높은 값에서 측정되었다. 통계 분석은 지대주의 높이, 시멘트의 종류에 대해 각각 Kruskal-Wallis test (P = 0.05) 후 Mann-Whitney U test (P = 0.0167)로 사후 검정 시행하였다. 결과: 임플란트 지대주의 높이에 상관없이 TB에 비해 FC의 제거력이 높았다. CI와 FC간에는 3 mm와 7 mm에서는 유의미한 차이가 있었으나 5 mm에서는 유의미한 차이가 없었다. TB와 CI간에는 5 mm에서만 유의미한 차이가 있었다. 결론: 시멘트의 종류는 지르코니아 수복물의 제거력에 유의미한 영향을 끼쳤으나, 임플란트 지대주의 높이는 유의미한 영향을 주지 않았다.

로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가 (Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife)

  • 정영준;정재홍;임광채;조은주
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 목 적: 로봇 사이버나이프에서 환자의 움직임에 의한 기준점의 위치변화 오차가 위치인식시스템(target location system, TLS) 을 통하여 targeting error값이 정확히 보정(correction)되는지 평가하고자 한다. 대상 및 방법: 본 실험은 targeting의 정확성을 분석하기 위해 head and neck팬텀에 Gafchromic 필름(MD-55)을 삽입한 후, 사이버나이프(CyberKnife Robotic Radiosurgery System G4, Accuray, US)의 6 MV X선을 조사하였다. 필름 분석은 Accuray사에서 제공하는 End to End (E2E) 프로그램을 이용하였다. 기준점의 위치에서 x, y, z방향으로 $0{\pm}0.2\;mm$, roll, pitch, yaw방향으로 $0{\pm}0.2^{\circ}$ 이내로 유지하여 12회 조사한 대조군과 인위적으로 움직임을 주어 실험을 시행한 6회의 실험군의 targeting 오차를 구하고, 대조군과 실험군의 평균값에 대한 유의성을 t-검정을 통해 분석하였다. 또한, gamma-index method (dose difference: 3%)를 통해 2차원적 선량분포의 일치성을 distance to agreement (DTA)를 각각 1 mm, 1.5 mm, 2 mm로 달리하여 정량화하고, 비교 분석하였다. 결 과: E2E test 시행 결과, 기준 필름의 targeting 평균오차 0.405 mm, 표준편차 0.069 mm, 실험 필름의 평균오차 0.413 mm, 표준편차 0.121 mm으로 나왔으며, t-검정 결과 유의확률 P=0.836 (신뢰구간 95%)으로 두 집단에서 유의한 차이를 볼 수 없었다. 또한, DTA를 각각 1 mm, 1.5 mm, 2 mm로 선량분포의 일치성을 비교한 결과 기준필름 3,314개 위치에서 axial필름 평균은 각각 95.04%, 97.56%, 98.13%, sagittal필름 평균은 각각 95.47%, 97.68%, 98.47% 일치하였다. 실험필름과 비교한 결과 3,323개 위치에서 axial필름 평균은 각각 96.38%, 97.57%, 98.04%, sagittal필름 평균은 각각 95.50%, 97.87%, 98.36% 일치하는 것을 확인할 수 있었다. 결 론: 로봇 사이버나이프는 치료 시 환자의 움직임에 의해 발생하는 기준점의 위치변화 오차를 실시간 추적하여 보정하며, targeting 오차를 1 mm 이내, 선량분포는 95% 이상 일치하는 정확성을 확인할 수 있었다.

  • PDF