• Title/Summary/Keyword: 정압력

Search Result 47, Processing Time 0.023 seconds

A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct (공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구)

  • Jo, Hyeong-Je;Jun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.145-160
    • /
    • 2018
  • Long subsea tunnel is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for tunnel ventilation. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. As a result, ventilation distance become longer and supply airflow becomes excessive due to air leakage, So, duct mounting for temporary ventilation is impossible or fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In previous study, we have found that air leakage is the key factor in solving these problems and experimental results show that the new connection method has a leakage rate of about $1.46mm^2/m^2$ (Jo et al., 2017). In this study, we present the experimental results of the measurement of the leakage rate of the prototype with the new connection method, and analyze experimentally the improvement of the leakage rate when applying the flexible cover inside the duct to improve the leakage performance of the existing connection method.

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

The Development of Optimal Path Model for Transport of Hazardous Materials (위험물 소송을 위한 최적경로모형 개발)

  • 조용성;오세창
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10b
    • /
    • pp.508-508
    • /
    • 1998
  • 위험물 차량사고는 일반차량의 교통사고시 발생하는 인명피해, 재산피해, 교통지체 외에 부가적으로 환경적 영향에 의한 엄청난 인명 및 재산손실을 유발시킬 수 있다. 따라서 이러한 위험물차량사고를 예방하고 피해를 최소로 줄이기 위해서는 위험물수송경로의 신중하고 체계적인 결정이 필수적이라 할 수 있다. 외국의 경우, 위험물의 방출이 미치는 환경적 영향에 대한 인식이 확대되면서 위험물 수송시 응급처리에 관한 연구, 위험물 수송에 따른 위험도 평가에 관한 연구, 위험물 수송시 고려해야할 여러 조건에 관한 연구, 위험물 수송경로 설정에 관한 연구 등이 진행되고 있다. 반면에 우리 나라는 위험물차량관리와 사고처리에 대해 실시간적인 관리를 목표로 하는 국가차원의 계획을 수립하고는 있지만, 현재 이와 관련된 연구는 거의 없는 실정이다. 앞으로 산업발달에 따른 위험물수송량의 증가와 환경의식의 변화에 따라 위험물수송 및 사고처리 등에 관한 연구가 필요할 것이다. 따라서, 본 연구는 위험물차량의 운송경로를 결정할 때 고려해야 할 여러 가지의 기준 및 목표에 따라 위험물수송경로를 설정하는 모형을 제시함으로써 위험물수송에 수반되는 위험을 최소화하면서 위험물차량의 통행시간, 거리, 비용 등을 최적화하여 위험물수송의 안전 및 운영효율성을 향상시키고자 한다. 먼저, 위험물 수송경로의 기준지표로 사용될 위험도를 산정하기 위해 링크 주변노출인구, 밀도 등을 변수로 하는 모형식을 제안하고, 두 번째로 산정된 위험도를 기반으로 최적경로를 결정하는 알고리즘을 제안하였다. 마지막으로 가상 네트웍에 본 연구에서 제안된 모형을 적용하고 현재 일반적으로 사용되는 최단경로와 비교·분석하였다.것은 운송거리와 운송비용이 각각 주요한 변수라는 것이다. 모형의 타당성을 검증하기 위해서는 logilikelihood 값을 구하여 $\rho$^2분석을 시행하였다. 여기서는 각 품목별로 $\rho$^2값이 약 0.15~0.3의 비교적 높은 수치를 보여주고 있으므로 모형의 설명력이 어느 정도 있다는 것이 아울러 증명이 되었다. 상관관계에 대한 분석에서는 영업용 차량간의 상관관계가 높게 나타났으며, 이는 곧 영업용 화물차량을 적재중량별로 구분하는 것이 별 의미가 없음을 의미한다. 다시 말하면 자가용 차량을 보유하고 있지 않은 회사는 다른 운송전문업체에 화물운송을 의뢰하게 되므로 출하중량에 따라 화물차량을 구분하는 것에 대해서 그다지 큰 고려를 하지 않는 것으로 해석할 수가 있다.적합함을 재확인함. 6. 혼잡초기를 제외한 혼잡기간 중 대기행렬길이는 밀도데이터 없이도 혼잡 상류부의 도착교통량과 병목지점 본선통과교통량만을 이용하여 추정이 가능함. 7. 이상에 연구한 결과를 토대로, 고속도로 대기행렬길이를 산정할 수 있는 기초적인 도형을 제시함.벌레를 대상으로 처리한 Phenthoate EC가 96.38%의 방제가로 약효가 가장 우수하였고 3월중순 및 4월중순 월동후 암컷을 대상으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압

  • PDF

Spontaneous Combustion of Various Fuels of Carbonization Rank (탄화도별 발전연료의 자연발화 특성 평가)

  • Kim, Jae-Kwan;Park, Seok-Un;Jeong, Jae-Hyeok;Shin, Dong-Ik;Hong, Jun-Seok;Hong, Jin Pyo
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.78-89
    • /
    • 2017
  • Spontaneous combustion propensity of various coals of carbonization grade as a pulverized fuel of coal fired power plant has been tested from an initial temperature of $25^{\circ}C$ to $600^{\circ}C$ by heated in an oven with air to analyze an self oxidation starting temperature. This tests produce a CPT(Cross Point Temperature), IT(Ignition temperature) and CPS(Cross Point Slope) by calculated as the slope of time taken a rapid exothermic oxidation reaction at CPT base. CPS show a carbonization rank dependence, whereby wood pellet has the highest propensity to spontaneous combustion of $20.995^{\circ}C/min$. A subbituminous KIDECO coal shows an CPS values of $15.370^{\circ}C/min$ whereas it of pet coke of the highest carbonization rank has $20.950^{\circ}C/min$. The nature of this trend is most likely a concentration of volatile matter and oxygen functional groups of coal surface that governs the available component for oxidation as well as surface area of fuel char, and constant pressure molar heat.

Development of a New Commercial Grain Cooler (곡물냉각기의 개발)

  • 김동철;김의웅;금동혁;한종규
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.250-256
    • /
    • 2004
  • The objectives of this study were to develop a new commercial grain cooler suited to domestic weather and post-harvesting conditions for paddy, and to evaluate the performance. A prototype grain cooler capable of cooling paddy of 200 tons within 24 hours was developed. The grain cooler was designed to control the refrigeration capacity from 0 to 100% by controlling the capacity of compressor with unloading solenoid valve and by changing the flow rates of hot refrigerant gas flowing into reheater and evaporator from compressor. And a controller with one chip microprocessor was developed to control temperature and relative humidity of cooling air. The maximum cooling capacity of the grain cooler was 35,284㎉/hr at condensing/evaporating pressure of 16.5/3.6 kgf/$\textrm{cm}^2$. Maximum flow rate of cooling air was 120 ㎥/min at static pressure of 279 mmAq. The total maximum required power was 22.8㎾, and total required energy was saved from 26.7 to 33.3% of maximum power depending on operating conditions. The coefficient of performance of refrigeration devices and total coefficient of performance of the grain cooler were 4.71 and 1.8, respectively.

Thermodynamic Analysis on Hybrid Turbo Expander - Heat Pump System for Natural Gas Pressure Regulation (히트펌프를 적용한 터보팽창기 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyoung Hoon;Han, Sangjo;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.13-20
    • /
    • 2014
  • In natural gas distribution system, gas pressure is regulated correspond to requirement using throttle valve which is releasing huge pressure energy as useless form. The waste pressure can be recovered by using turbo machinery devices such as a turbo expander. In this process, excessive temperature drop occurs due to Joule-Thompson effect during the expansion process. Installing natural gas boiler before or after the turbo expander prevents temperature drop. Fuel cell or gas engine hybrid system further improve the efficiency, but 1~2% of total transporting natural gas is used for operating the hybrid system. In this study, a heat pump system is proposed as a preheating device which can be operated without using transporting natural gas. Thermodynamic analysis on evaporating and condensing temperatures and refrigerants is conducted. Results show that R717 is proper refrigerant for the hybrid system with high COP and low turbine work within the defined operating conditions. In domestic usage in Korea, the heat pump system has more economic feasibility owing to natural gas being imported with a high price of LNG form.

Design Study of Engine Inlet Duct for Measurement Improvement of the Flow Properties on AIP (AIP면 유동측정 정확도 향상을 위한 가스터빈엔진 입구덕트 설계 연구)

  • Im, Ju Hyun;Kim, Sung Don;Kim, Yong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.49-55
    • /
    • 2017
  • In this study, gas turbine engine inlet duct was designed to satisfy uniform flow at aerodynamic interface plane (AIP). Haack-series was selected as nose cone profile and duct outer radius($r_o$) was designed to satisfy to match with area change rate between the nose cone and outer duct wall by the 1-D sizing. The design object of the inlet duct wall profile which has the gradual area change rate was uniform Mach number in the core flow region and minimum boundary later thickness at the both inner nose wall and outer duct wall. The flow characteristics inside the inlet duct was evaluated using CFD. The static pressure distribution at the AIP showed uniform pattern within 0.16%. Based on Mach number profile, the boundary layer thickness was 2% of channel height. Kiel temperature rake location was decided less than 100 mm in front of nose cone where the Mach number is less than 0.1 in order to maximize the temperature probe recovery rate.