• Title/Summary/Keyword: 정시 렌즈

Search Result 25, Processing Time 0.019 seconds

The Study on Change of Refractive error and Addition in Progressive Eyeglasses Lens Wearers (누진렌즈안경 착용자의 가입도와 굴절이상 변화에 대한 연구)

  • Joo, Seok-Hee;Shim, Moon-Sik;Shim, Jun-Beom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.399-404
    • /
    • 2013
  • Purpose: This study was to analyse the changes of refractive error and addition in progressive eyeglasses lens wearers. Methods: Data of 244 subjects who have been prescribed progressive eyeglasses lenses were used for analysis. The range of age was between 43~69 old years and they visited the optical shop in Gwangju metropolitan city from 2003 to 2013. According to the refractive state and age, The changes of refractive error and addition was analysed respectively. Results: The changes of distance refractive power by refractive error was showed +0.10 D in emmetropia, +0.07 D in myopia, +0.23 D in hyperopia (p=0.000). The change of addition was showed +0.22 D in emmetropia, +0.29 D in myopia, +0.17 D in hyperopia (p=0.000). The changes of distance power and addition by age was +0.08 D distance refractive power, +0.30 D addition in the group of 40~49 old years, +0.17 D distance refractive power, +0.20 D addition in the group of 50~59 old years and +0.15 D distance refractive power, +0.14 D addition in the group of 60~69 old years (p=0.046, p=0.006). Conclusions: The changes of refractive error and addition of progressive eyeglasses lens wearers in all refractive state and age were gradual increase in the direction (+) diopter.

Changes of Body Balance on Static Posture According to Types of Induced Ametropia (정적자세에서 유도된 비정시의 유형에 따른 신체균형의 변화)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose: This study was performed to investigate the effect of induced ametropia on static posture for body balance. Methods: Twenty subjects (10 males, 10 females) of average age $23.4{pm}2.70$ years were participated and ametropia(binocular myopia; BM, simple myopic anisometropia; SMA, binocular hyperopia; BH, and simple hyperopic anisometropia; SHA) were induced with ${pm}0.50D$, ${\pm}1.00D$, ${\pm}1.50D$, ${\pm}2.00D$, ${\pm}3.00D$, ${\pm}4.00D$, ${\pm}5.00D$, respectively. General stability (ST), weight distribution index (WDI), and fall risk index (FI) were measured using TETRAX the biofeedback systems. Each index of the body balance was evaluated for 32 seconds in each ametropic condition and those value was compared with the value in fully corrected condition. Results: The ST showed significant increase from +0.50 D under condition of BM, from +1.00 D under condition of SMA, from -1.00 D under condition of BH, and from -1.50 D under condition of SHA compared with under condition of fully corrected condition, respectively. The FI showed significant increases from +4.00 D under condition of BM, from -1.00 D under condition of BH, and from -1.50 D under condition of SHA. The WDI show no change in all ametropia condition. Conclusions: Whatever ametropia is, uncorrected refractive error could reduce the general stability of body balance and increase the falling risk.

A Comparative Analysis of increased along with the age presbyopic additions in city and island villages (도시와 섬마을 노안의 연령에 따른 근용 가입도의 비교 관찰)

  • Kim, In-Suk;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.61-65
    • /
    • 2002
  • This study examines how the average presbyopic additions and eye refraction state of old ages in city may be different to that island. There were 677 of the old who were 50 or over 90 in the sample. The visual acuity test was done by objective and subjective methods and used for near-chart program. The far-point refraction state and power of the additions lens results were as follows ; 1. Of far-point refraction state in city peoples; male: emmetropia 10%, myopia 17%, hyperopia 19%, mixed astigmatism 38%, etc. 16% female : emmetropia 20%, myopia 20%, hyperopia 20%, mixed astigmatism 27%, etc. 13% 2. Of far-point refraction state in island villages ; male : emmetropia 13%, myopia 17%, hyperopia 22%, mixed astigmatism 40%, etc. 8% female : emmetropia 7%, myopia 13%, hyperopia 26%, mixed astigmatism 44%, etc. 10% 3. Average presbyopic additions states has been presented no discrimination ; male: 50 to 60 : +1.25 or +1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.75 or +3.00D, 76 to 80 : +3.25 or +3.50D, over81 : +3.75D female : 50 to 60 : +1.25 or + 1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.25 or + 2.50D, 76 to 80 : +2.75 or +3.00D, over81 : +2.75 or +3.00D 4. Under the condition of wearing lens, the average working time was 1 or 2 hour but some people used over 5 hours. 5. Generally, it has been investigated the old ages peoples has ocular diseases and cataract was the most common.

  • PDF

Relationship on the Refractive Status of the High School 3rd Grade Students with Subnormal Visual Acuity in Gwangju Metropolitan City (광주지역 고등학교 3학년생의 비정시안의 굴절상태에 대한 고찰)

  • Yoon, Young;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • To investigate the ametropia and refractive error of 222 ametropic eyes of the 111 high school students in Gwangju Metropolitan City, the visual acuity test was performed by the object and subject method. 85% of the eye types were positive for myopia, 14% for emmetropia, and 1% for hyperopia, respectively. 38% of the abnormal refraction eyes were positive for simple myopia, 4% for myopia simple astigmatism, 56% for myopia compound astigmatism, and 0% for simple hyperopia, 0% for hyperopia simple astigmatism, 2% for hyperopia compound astigmatism, 0% for mixed astigmatism, respectively. 92% of the axes fo astigmatism were for astigmatism with-the-rule, 6% for astigmatism against-the rule, 2% for astigmatism oblique, respectively. As for the astigmatic power, 0.50 < cylinder < 1.00D was 68%, 1.00 < cylinder < 2.00D was 25%, and anything over the 2.00 cylinder D was 7%. As for the equivalent spheric power of myopic abnormal refraction eyes, -0.50 < spheric equivalent < -2.00D was 26%, -2.00D < spheric equivalent < -6.00D was 55% and anything over the -6.00D was 19%. The rate of wearing glasses was 74%. It increases compared to 20 years ago. 91% of the eye test place was the optical shop, 9% the eye doctor hospital. 80% of the students need to change their optical lenses because spherical equivalent power was over 0.50D.

  • PDF

The Study for Refractive Error of the Westerner in 20s: North America Region (20대 서양인의 굴절이상에 대한 연구: 북미지역)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.97-101
    • /
    • 2009
  • Purpose: To assess the refractive state of the westerners (male: 44, female: 62) in twenties who visited the A optical shop at Seoul. Methods: The visual acuity test was performed by the objective and subjective method. Results: The emmetropia and myoptia were 35 and 177 eyes (83.49%), respectively. About 26.76% of tested males was ametropia. Myopia compound and myopia simple astigmatism were found in 60.56% and 12.68% of tested males, respectively. However, about 43.40% of tested females was ametropia. Myopia compound and myopia simple astigmatism were 49.06% and 7.55% were found in tested females, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -0.5D < spheric equivalent ${\leq}$ -2.00D was 35.02% of tested westerners, the -2.00D < spheric equivalent ${\leq}$ -6.00D was 60.45% and anything over the -6.00D was 4.53%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 59.82%, 26.78% and 13.40%, respectively. The average of pupillary distance in male (63.5${\pm}$2.4 mm) was greater than that in female (59.7${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription for the westerners in twenties by this research.

  • PDF

The optical properties on the human model eye (모형 안의 광학적 성능)

  • Lim, Hyeonseon;Ji, Taeksang;Kim, Bonghwan;Kim, Sejin;Yoon, Sungro
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.203-207
    • /
    • 2002
  • In this study, by using the eye model of NAVARRO, KOOIJMAN, MAHKICHOONG, the properties of optical system are reserched in a finite ray tracing method, when ametropia is corrected by glasses or contact lens, this study is useful as a reference. Also, when Auto-refractometer for refraction test and Keratomeler are designed, these eye models can be used.

  • PDF

액셀러레이터의 스타트업 투자의사결정 영향요인에 관한 연구

  • Han, Ju-Hyeong;HwangBo, Yun
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2018.11a
    • /
    • pp.283-288
    • /
    • 2018
  • 스타트업의 자금조달 능력은 초기 스타트업 생존에 가장 직결되는 문제이다. 스타트업은 정부 지원금을 비롯하여 엔젤투자자, 벤처캐피탈 등으로부터 자금을 지원받고 있지만 초기기업 회수시장의 불확실성으로 인해 투자 규모는 작은 편이다. 이에 따라 초기기업에 투자함과 동시에 경영 및 기술 멘토링, 교육, 관리 등을 체계적으로 지원하는 '액셀러레이터'가 최근 창업생태계의 핵심으로 떠오르고 있다. 액셀러레이터는 단순하게 인큐베이팅 시스템을 제공하는 것이 아니다. 초기기업의 팀빌딩부터 성장 과정을 함께하는 '공동 창업자'와 같은 역할을 하면서 이들이 성장해나갈 수 있도록 집중적인 멘토링과 교육 등의 프로그램을 제공한다. 이러한 시스템을 거친 스타트업은 생존 기간이 상대적으로 높고, 벤처캐피탈도 이렇게 성장한 스타트업 투자에 보다 더 적극적으로 참여하는 경향이 있다. 하지만 액셀러레이터 설립의 역사가 오래되지 않아, 관련 연구는 비교적 다양하지 않은 편이다. 이에 본 연구에서는 엔젤투자자, 벤처캐피탈과 다른 액셀러레이터의 특징이 무엇인지 분석하고, 특히 액셀러레이터가 스타트업 투자의사결정시 영향을 미치는 요인에는 어떤 것들이 있는지 렌즈모델을 통해 알아보고자 한다.

  • PDF

Comparison of Stereopsis by Influence Factors in Induced Aniseikonia (유발 부등상시에서 영향인자에 따른 입체시의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.465-471
    • /
    • 2013
  • Purpose: This study was conducted to research effects of influence factors on stereopsis of induced aniseikonia in emmetropia. Methods: 20 college students (a mean age of $22.50{\pm}2.72$ years, 14 males, 6 females) were selected as subjects and all of them had no ocular disease or systemic disease, the refractive correction of spherical equivalent within ${\pm}0.50$ D, the corrected visual acuity of 1.0 or better and the aniseikonia values less than 1% by AWAYA. Subject's dominant eye was checked by Hole in card method and contact lenses of -7.00 ~ +7.00D were fitted to cause anisometropia in dominant eye or non-dominant eye, respectively. And then aniseikonia was induced with spectacles to correct refractive error by contact lenses. Stereopsis was measured by Random Dot Stereo Acuity Test with LEA symbols$^{(R)}$ (Vision Assessment Corporation$^{TM}$, USA). Results: Stereopsis was remarkably reduced by inducing aniseikonia, with induced aniseikonia in dominant eye, with higher diopter of wearing contact lenses to induce anisometropia, with spectacles lenses correction of minus power after fitting contact lenses with plus power and in case of men. Conclusions: It should be considered to correct anisometropia that aniseikonia could cause reduction of stereopsis.

A Study on the Spectacles Wearing State of High School Students (고등학생들의 안경착용에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • This study is of investigation of refraction error, spectacles and contact lenses wearing state, visual acuity test, ophthalmologic common sense and vision care, using questionnaire study for 850 male and female high school students in Kunsan and Chongup City, Cheolla North Province. The results are as follows: 1. Among the 823 answerers, emmetropia is 18%, myopia is 55.1%, and hyperopia is 7%, respectively. 2. Among the 837 answerers, 381 students(45.5%) wear spectacles or contact lenses. Among the 381 students who wear spectacles or contact lenses, 78% wear only spectacles, 4% wear only contact lenses and 18% wears spectacles sometimes or contact lenses sometimes. 3. The places where the answerers had visual acuity test to wear spectacles or contact lenses are optical shop(64.7%), hospital(28.3%), unchecked(4.2%) and the others(2.7%). The places where the answerers had visual acuity test to change their spectacles or contact lenses are optical shop(82%), hospital(28.3%), unchecked(6.6%) and the others(1.9%). 4. As for the period of visual acuity test, from 6 months to one year is 54.1%, within 6 months is 9.2%, from one year to two years is 29.5%, and more than two years is 7.2%. 5. The contact lens wearers purchased their contact lenses at optical shops(94%) and at hospital(6%). 6. The reasons why they like wearing contact lenses are their appearance(51.2%), convenience in physical excercise(23.l%), lighter weight than spectacles(9.8%) and the others(15.7%). 7. As for the spectacles frame they like, plastic frame is 24.4%, gold or silver plated frame is 43.4%, coloured frame is 32.1%. 8. As for the considerations in choosing spectacles frame, their design is 37%, their quality is 36%, their price is 14.7% and their brand is 12.5%. 9. As for the period for changing spectacles, 10.5% is within 6 months, 57.3% is 6months to 1 year, 22.4% is 1 year to 2 months and 9.6% is more than 2 years. 10. There is a false fact, in Korea, that even though one has his poor eyesight, not wearing custom is helpful for the eyesight recovery. As for their conviction of the false fact, 10.5% of the answerers have 100% conviction, 22.5% of them have 22.5% conviction, 49.5% of them have 50% conviction and 17.5% of them don't have any conviction. 11. 48.5% of the answerers are interested in their vision care while 51.5% of them are not interested at all. As for the way of vision care, the vision-care way to keep enough distant when they are watching TV, when they are using computers and when they are reading, is 49% while the vision-care way such as hypogastric breathing or eye massage is 11%. And alimentotherapy is 4% and the rest who are not interested in vision care is 36%. 12. When they come to an age, the students who want vision correction operation are 45.9% while the students who do not want it are 27%. The students who do not have any idea about the operation are 27.1%

  • PDF

Clinical Efficacy of Bunny Multifocal Intraocular Lens after Cataract Surgery (버니 다초점인공수정체의 임상적 효용성)

  • Cho, Myung Ho;Park, Jae Yeong;Park, Byung Gun;Lee, Jong Soo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1129-1136
    • /
    • 2018
  • Purpose: To compare the postoperative clinical outcomes after cataract surgery and implantation using the BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ multifocal intraocular lenses. Methods: Sixty-five eyes implanted with multifocal intraocular lenses were divided into two groups involving either $ReSTOR^{(R)}$ (39 eyes) or BunnyLens $MF^{(R)}$ (26 eyes) lenses. In these two groups, the distant and near visual acuity, astigmatism, spherical equivalent, and contrast sensitivity test were examined at preoperative and postoperative 1 week, 8 weeks, and 24 weeks. We compared the clinical efficacy between the two groups before and after cataract surgery using statistical analysis. Results: The mean value of distant and near visual acuity, and spherical equivalent of both groups after intraocular lens implantation were significantly improved, compared with the preoperative values (p < 0.05), while there was no significant differences between the two groups (p > 0.05). The means of postoperative distant and near visual acuity, astigmatism, and contrast sensitivity test were not significantly different between $ReSTOR^{(R)}$ and BunnyLens $MF^{(R)}$ lenses (p > 0.05). The mean numeric error of spherical equivalent at the final postoperative 24 weeks was $-0.17{\pm}0.50$ diopters (D) for the $ReSTOR^{(R)}$ lenses and $-0.34{\pm}0.52D$ for the BunnyLens $MF^{(R)}$ lenses (p > 0.05). Conclusions: BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ lenses showed no significant difference in clinical efficacy, including distance and near vision, spherical equivalent error, and contrast sensitivity test after cataract surgery. However, it should be noted that BunnyLens $MF^{(R)}$ lenses had a tendency toward myopic shift compared with $ReSTOR^{(R)}$ lenses.