• Title/Summary/Keyword: 정상 성능

Search Result 2,093, Processing Time 0.021 seconds

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.

Developing algorithms for providing evacuation and detour route guidance under emergency conditions (재난.재해 시 대피 및 우회차량 경로 제공 알고리즘 개발)

  • Yang, Choong-Heon;Son, Young-Tae;Yang, In-Chul;Kim, Hyun-Myoung
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.129-139
    • /
    • 2009
  • The transportation network is a critical infrastructure in the event of natural and human caused disasters such as rainfall, snowfall, and terror and so on. Particularly, the transportation network in an urban area where a large number of population live is subject to be negatively affected from such events. Therefore, efficient traffic operation plans are required to assist rapid evacuation and effective detour of vehicles on the network as soon as possible. Recently, ubiquitous communication and sensor network technology is very useful to improve data collection and connection related emergency information. In this study, we develop a specific algorithm to provide evacuation route and detour information only for vehicles under emergency situations. Our algorithm is based on shortest path search technique and dynamic traffic assignment. We perform the case study to evaluate model performance applying hypothetical scenarios involved terror. Results show that the model successfully describe effective path for each vehicle under emergency situation.

  • PDF

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

A Multicast Middleware for the Remote Educational Systems (원격 교육 시스템을 위한 멀티캐스트 미들웨어)

  • Byun, Sang-Seon;Jin, Hyun-Wook;Yoo, Hyuck
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.1
    • /
    • pp.100-108
    • /
    • 2003
  • By choosing Multicast for transmission of educational contents in the Remote Educational System, we can reduce the server load and increase network bandwidth utilization. We design and implement Multicast Middleware for the Remote Educational System in this paper. There are three characteristics in this Multicast Middleware: 1) Through Centralized Multicast Group Management for passive members, it allows a host to make multicast group, which is composed of receivers, called Group Member and who are chosen by the host, called group Maker. Because, all groups are created by the Group Maker in Centralized Group Management, Group Member's join action will be passive 2) Maintenance and recovery of multicast group information in order to restore from exception and crash; the maintenance and recovery mechanism of Group Maker is distinct from that of Group Member. 3) The mechanism which enables to transmit large size multimedia data through multicasting and remove additional copy operation through shared buffer. Fragmentation/de-fragmentation for large data delivery results in additional copy operation in user level. But by using user level shared buffer, it can be done without user Bevel copy operation. By applying to Remote Educational environment which consists of 30 PCs and Fast Ethernet, we can examine the efficiency of this middleware, which can transmit 18frames/sec movie which resolution 320 $\times$ 120 pixels, 128Kbps encoded sound data and some text data.

Characteristics and Dynamic Modeling of MR Damper for Semi-active Vibration Control (준능동 진동 제어를 위한 MR 감쇠기의 동적 모델링을 통한 특성분석)

  • Heo, Gwang-Hee;Jeon, Seung-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.61-69
    • /
    • 2013
  • This research is aimed to evaluate characteristics and dynamic modeling of MR damper for semi-active vibration control. A MR damper of semi-active type was designed and made for the purpose of controlling the vibration of a real-size model structure. Usually a semi-active control system equipped with a MR damper requires a dynamic model which expresses numerical data about the damping capacity and dynamic characteristics generated by a MR damper. To fulfil the requirement, a Power model and a Bingham model were particularly employed among many dynamic models of MR damper. Those models being contrasted with other ones, a dynamic test was carried out on the developed MR damper. In the test, excitation frequencies were conditioned to be 0.15 Hz, 1.0 Hz, and 2.0 Hz, and three different currents were adopted for each frequency. From these test results, it was found that displacement affected control capacity of the MR damper. The test results led to the identification of model variables for each dynamic model, on the basis of which a force-speed relation curve and expected damping force were derived and contrasted to those of the developed MR damper. Therefore, it was proven that the MR damper designed and made in this research was effective as a semi-active controller, and also that displacement of 2mm at minimum was found to be secured for vibration control, through the test using various displacements.

Effect of pH on Growth and Cultural Characteristics of Bacillus sp. SH-8 and Bacillus sp. SH-8M (Bacillus sp. SH-8과 Bacillus sp. SH-8M의 생육 및 배양 특성에 미치는 pH의 영향)

  • 심창환;신원철;유주현
    • Microbiology and Biotechnology Letters
    • /
    • v.20 no.4
    • /
    • pp.371-376
    • /
    • 1992
  • The growth and cultural characteristics of Bacillus sp. SH-8 and SH-8M were investigated at various pH conditions. Bacillus sp. SH-8 showed normal growth pattern above pH 9.0. However, with the pH adjusted below 7.7, 0.$D_{550}$ decreased rapidly with concomitant reduction in viable cell numbers. In contrast, Bacillus sp. SH-8M demonstrated growth capability at pH 7.7, but with slightly reduced growth rate at pH 6.9. Similar results were obtained when those two strains were cultivated on the solid medium. Both of them showed short rod shapes at pH 10.2. However, at pH 7.7 only Bacillus sp. SH-8 was observed to have elongated rod shape. Extracellular pH of both the strains, when cultured at initial pH of 10.2, reached to 9.0 after the incubation of 28 hours. At the initial pH of 9.0 and 9.6, the extracellular pH was reduced at the beginning of cultivation, but elevated after 12 hours. When cultured at initial pH of 6.9 and 7.7, extracelluar pH of Bacillus sp. SH-8M increased to 8.0 and 8.7, respectively, while that of Bacillus sp. SH8 remained constant pH 7.0. The highest sporulation rate of Bacillus sp. SH-8 and SH-8M was obtained at the initial pH of 10.2 and after the incubation of 3 days with the sporulation rate of 95% and 85%, respectively.

  • PDF

The Optimization of Hybrid BCI Systems based on Blind Source Separation in Single Channel (단일 채널에서 블라인드 음원분리를 통한 하이브리드 BCI시스템 최적화)

  • Yang, Da-Lin;Nguyen, Trung-Hau;Kim, Jong-Jin;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.1
    • /
    • pp.7-13
    • /
    • 2018
  • In the current study, we proposed an optimized brain-computer interface (BCI) which employed blind source separation (BBS) approach to remove noises. Thus motor imagery (MI) signal and steady state visual evoked potential (SSVEP) signal were easily to be detected due to enhancement in signal-to-noise ratio (SNR). Moreover, a combination between MI and SSVEP which is typically can increase the number of commands being generated in the current BCI. To reduce the computational time as well as to bring the BCI closer to real-world applications, the current system utilizes a single-channel EEG signal. In addition, a convolutional neural network (CNN) was used as the multi-class classification model. We evaluated the performance in term of accuracy between a non-BBS+BCI and BBS+BCI. Results show that the accuracy of the BBS+BCI is achieved $16.15{\pm}5.12%$ higher than that in the non-BBS+BCI by using BBS than non-used on. Overall, the proposed BCI system demonstrate a feasibility to be applied for multi-dimensional control applications with a comparable accuracy.

Development of Fog Cooling Control System and Cooling Effect in Greenhouse (온실 포그 냉방 제어시스템 개발 및 냉방효과)

  • Park, Seok Ho;Moon, Jong Pil;Kim, Jin Koo;Kim, Seoung Hee
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.265-276
    • /
    • 2020
  • This study was conducted to provide a basis for raising farm income by increasing the yield and extending the cultivation period by creating an environment where crops can be cultivated normally during high temperatures in summer. The maximum cooling load of the multi-span greenhouse with a floor area of 504 ㎡ was found to be 462,609 W, and keeping the greenhouse under 32℃ without shading the greenhouse at a high temperature, it was necessary to fog spray 471.6 L of water per hour. The automatic fog cooling control device was developed to effectively control the fog device, the flow fan, and the light blocking device constituting the fog cooling system. The fog cooling system showed that the temperature of the greenhouse could be lowered by 6℃ than the outside temperature. The relative humidity of the fog-cooled greenhouse was 40-80% during the day, about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The relative humidity of the fog cooling greenhouse during the day was 40-80%, which was about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The yield of cucumbers in the fog-cooled greenhouse was 1.8 times higher in the single-span greenhouse and two times higher in the multi-span greenhouse compared to the control greenhouse.

Feasibility Study of Improved Train Control System Using On-board Controller for Intelligent Control of Trackside Facilities (선로변 시설물의 지능적 제어를 위한 차상중심 열차제어시스템 시뮬레이션 기반 성능 평가)

  • Baek, Jong-Hyen;Jo, Hyun-Jeong;Chae, Eun-Kyung;Choi, Hyun-Young;Kim, Yong-Gyu
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.528-533
    • /
    • 2013
  • To improve the efficiency and safety of railway systems, the train control system has considerably evolved from the ground-equipment-based control system (e.g. track circuit, interlocking system, etc.) into the on-board-equipment-based control system. In addition, this train control system enables the rolling stock to intelligently control the trackside facilities by introducing information and communication technologies (ICT). Accordingly, since the ICT-based train control system simplifies the railway system (i.e. the heavy ground-equipment can be removed), an efficient and cost-effective railway system can be realized. In this paper, we perform a feasibility test of the ICT-based train control system using a simulation. To this end, we implement a test-bed consisting of prototype machines of on-board/ground equipment and introduce an integrated operation scenario for the train control. The simulation results satisfy all the requirements of train operation according to the scenario and show the effectiveness of the proposed train control system.

A small ocean bottom electromagnetometer and ocean bottom electrometer system with an arm-folding mechanism (Technical Report) (팔-접힘 구조를 가지는 소규모 OBEM과 OBE시스템 (기술보고서))

  • Kasaya, Takafumi;Goto, Tada-nori
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Natural magnetic fields are attenuated by electrically conductive water. For that reason, marine magnetotelluric surveys have collected data at long periods (1000-100 000 s). The mantle structure has been the main target of seafloor magnetotelluric measurements. To ascertain crustal structure, however, electromagnetic data at shorter periods are important, e.g. in investigations of megathrust earthquake zones, or in natural resource surveys. To investigate of the former, for example, electromagnetic data for periods of less than 1000 s are necessary. Because no suitable ocean bottom electromagnetometer (OBEM) has been available, we have developed a small OBEM and ocean bottom electrometer (OBE) system with a high sample rate, which has an arm-folding mechanism to facilitate assembly and recovering operations. For magnetic observation, we used a fluxgate sensor. Field observations were undertaken to evaluate the field performance of our instruments. All instruments were recovered and their electromagnetic data were obtained. Results of the first experiment show that our system functioned well throughout operations and observations. Results of other field experiments off Tottori support the claim that the electromagnetic data obtained using the new OBEM and OBE system are of sufficient quality for the survey target. These results suggest that this device removes all instrumental obstacles to measurement of electromagnetic fields on the seafloor.