• Title/Summary/Keyword: 정상상태 시뮬레이션

Search Result 370, Processing Time 0.028 seconds

Design of a Variable Structure Speed Controller having a Dead Zone Switching layer for the Sinusoidal type Brushless DC Motor (데드 존 스위칭 영역을 갖는 정현파형 브러시리스 직류전동기의 가변구조 속도제어기 설계)

  • 김세일;최중경;박승엽
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.639-650
    • /
    • 1999
  • In this paper, a chattering alleviation VSS controller for the sinusoidal type BLDC motor is designed. Dead Zone function is proposed to change the chattering occurring in the transient state from high frequency to low frequency and time-varying gains are applied for the control input to eliminate the steady state excessive chattering in the conventional ISM. The proposed Dead Zone function represents the sliding layer composed of two switching surfaces and if a state vector exists in this layer, the chattering don't occur. Simulation and experimental results confirm the useful effects of the above algorithm.

  • PDF

Steady State Kalman Filter based IMM Tracking Filter for Multi-Target Tracking (다중표적 추적을 위한 정상상태 칼만필터 기반 IMM 추적필터)

  • 김병두;이자성
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.71-78
    • /
    • 2006
  • When a tracking filter may be designed in the Cartesian coordinate, the covariance of the measurement errors varies according to the range and the bearing of an interested target. In this paper, interacting multiple model based tracking filter is formulated in the Cartesian coordinate utilizing the analytic solution of the steady state Kalman filter, which can be able to consider the variation of the measurement error covariance. 100 Monte Carlo runs performed to verify the proposed method. The performance of the proposed method is compared with the conventional fixed gain and Kalman filter based IMM tracking filter in terms of the root mean square error. The simulation results show that the proposed approach meaningfully reduces the computation time and provides a similar tracking performance in comparison with the conventional Kalman filter based IMM tracking filter.

Optimum Detector Location for Collecting Traffic Information using Microscopic Traffic Simulator for Interrupted Flow (미시 교통류 모형을 이용한 단속류 교통정보 수집용 검지기의 최적 위치 결정)

  • 오기도
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.226-235
    • /
    • 1998
  • 본 논문에서는 추종 모형을 이용한 미시 교통류 시뮬레이션 모형을 개발하고, 이 모형을 통한 시뮬레이션을 통하여 단속류에서 검지기의 설치 위치에 따른 검지 특성을 알아보고, 교통정보 수집용의 검지기의최적 위치에 대해 평가하였다. 검지기로부터 발생하는 교통량, 점유율, 속도 자료중 링크의 통행시간을 가장 잘 반영하는 것은 점유율에 의한 검지기의최적위치는 정지선으로부터 150∼250m이다. 점유율 다음으로 통행시간을 잘 반영하는 자료는 지점속도로서 점유율보다는 상관관계가 낮지만, 양호한 설명력을 가지는 것으로 보인다. 교통량 자료는 상관관계가 낮으며, 교통량에 의한 위치 선정은 각 모의 실험 결과에서 일관적이지 않아 적절한 설명변수가 아니라고 판단하였다. 모든 경우에서, 정지선이나 링크 최상류에 위치한 검지기로부터의 자료는 통행시간과 독립적이므로 이러한 검지기는 교통정보 수집용을 사용할 수 없으며, 일반적인 검지기의최적 위치는 정상상태의 교통류 뿐만 아니라 대기행렬내에 존재하여 매우 혼잡한 상태를 경험할 수 있는 위치라고 할수 있다.

  • PDF

Development of the Tuning-Support Program for Neutronics Model in the NPP Simulator (원전 시뮬레이터 노심모델 Tuning 지원 프로그램 개발)

  • Seo In-Yong;Hong Jin-Hyuk;Lee Myeong-Soo;Koh Byung-Marnr
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.11a
    • /
    • pp.165-170
    • /
    • 2005
  • 원전 시뮬레이터의 노심모델(REMARK)은 원자로에서 발생하는 1차원 열원을 정확히 모사하고, 정상상태 및 과도상태의 반응도 변화에 따른 중성자속의 거동을 실제 원자로와 유사하게 모사할 수 있어야 한다. 모사의 정확성을 높이기 위해 Tuning 작업이 필수적이나 그 작업 단계가 매우 복잡하여 많은 시간과 노력이 필요하기 때문에 이를 간소화하면서 정확성을 높일 수 있는 Tuning 지원 프로그램을 개발하였다. 개발된 프로그램의 사용결과 신속하고 정확한 Tuning이 가능하였다.

  • PDF

Control for Transient State Characteristics Improvement of Bidirectional Soft-switching DC-DC Converter for ESS (ESS용 양방향 소프트 스위칭 DC-DC 컨버터의 과도상태 특성개선을 위한 제어기법)

  • Kim, Hak-Soo;Lee, Jaewoon;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, Heung-Geun;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.137-138
    • /
    • 2016
  • 본 논문에서는 ESS용 양방향 소프트스위칭 DC-DC 컨버터의 과도상태개선을 위한 제어기법을 제안한다. 양방향 DC-DC 컨버터를 소프트스위칭하기 위해 DCM으로 동작시킬 경우 스위치의 턴오프시 손실이 가장 많이 발생하므로 이를 저감하기 위해 ZVS 턴오프 커패시터를 스위치에 추가한다. 하지만 정상상태와 달리 초기구동을 하거나 충 방전 모드전환의 경우에는 ZVS 턴오프 커패시터로 인해 오히려 과도상태특성이 나빠질 수 있다. 이를 개선하기 위하여 ZVS 턴오프 커패시터로 인해 발생하는 과도상태의 문제점을 분석하고 제어기법을 제안하였으며 제안하는 제어기법의 타당성을 시뮬레이션을 통해 검증하였다.

  • PDF

On-site Application of a Vehicle Tunnel Ventilation Simulator (도로터널 환기시뮬레이션 모델 현장적용 연구)

  • 이창우;김효규
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.319-327
    • /
    • 2001
  • Introduction of new design tools has been required to optimally design and operate the ventilation system of long vehicle tunnels.. The demand has led to wide spread use of the simulation technique throughout the would to analysis the dynamic relationship among the variables associated with vehicle tunnel ventilation. This paper aims at performing on-site study at local tunnels to test the applicability of NETVEN, a simulation model vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels model of vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels employing different ventilation systems as well as traffic methods. There were some discrepancies sound between the simulation output and measurements and the following four factors are considered to mainly cause those disagreement. (1) The real situation shows distinctive transient and retarding characteristics with respect to air flow and contaminant dispersion, while ventilation forces are not steady-state and in particular those traffic and climatic variables show significant instantaneous variation. (3) Near the exit portal, the CO levels show bigger differences. The general trend is that data with higher CO concentrations carry bigger discrepancies. Turbulent diffusion is though to be the main reason for it and also contribute to the fact hat the highest CO concentrations are found at the locations somewhat inward, not at the exit portals. (4) Higher traffic rate results in higher discrepancies of ventilation velocity. Along with the exhaust characteristics, the vehicle aerodynamic characteristics need to be studied continuously in order to reduce the velocity disagreement.

  • PDF

Variable Step Size Maximum Power Point Tracking Control based on Fuzzy Logic for a Small Wind Power System (소형풍력발전시스템을 위한 퍼지로직 기반의 듀티비 변화량 가변 MPPT 제어)

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.263-264
    • /
    • 2011
  • 본 논문은 풍력발전시스템의 MPPT 제어 시 정상상태에서의 안정성 향상을 위하여 퍼지로직 기반의 듀티비 변화량 가변 MPPT 방법을 제안한다. 일정한 듀티비 변화량으로 MPPT 제어 시 추종시간이 느려지거나 최대출력 점에서 진동하는 단점이 있다. 출력 전류량에 따라 구성된 퍼지로직 기반으로 듀티비 변화량을 가변 하여 MPPT 제어 시 정상상태 특성과 시스템 응답특성을 향상 시킬 수 있다. 3kW급 계통연계형 풍력발전시스템을 기반으로 수행된 시뮬레이션 결과를 바탕으로 제안한 알고리즘의 타당성을 검증하였다.

  • PDF

Control of Systems Containing Deadzone of PID Controller using Fuzzy Compensator and Fuzzy Tuner (퍼지 보상기와 퍼지 동조기를 이용한 PID제어기의 Deadzone을 포함한 시스템 제어)

  • 박재형;김승철;조용성;최부귀
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.403-410
    • /
    • 1999
  • A conventional PID controller has poor performance when it applied to systems with unknown deadzones. To solve this problem, this paper proposes PID controller using two layered-fuzzy logic. The structure of controller is reconstructed with fuzzy compensator and fuzzy tuner on the conventional PID controller. Our proposed control scheme shows superior transient and steady-state performance compared to conventional PID controller. The scheme is robust to variations in deadzone nonlinearities as well as the steady-state gain of the plant. The performance of the developed controller is verified through simulation.

  • PDF

Quasi-DC link type tapped-inductor Buck-Boost Micro Inverter (유사 DC-link형 탭인덕터 벅-부스트 마이크로 인버터)

  • Jang, Jong-Ho;Seo, Jung-Won;Kim, Seok-Hee;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.195-196
    • /
    • 2012
  • 본 논문에서는 저가형 고효율의 탭인덕터 벅-부스트 마이크로 인버터를 제안한다. 제안하는 인버터는 정상상태 연속모드(CCM)에서 단상전력계통에 고역률의 정현파전류를 공급할 수 있는 새로운 구조이다. 강압시에는 벅모드로 동작하며, 승압시에는 탭인덕터 부스트 모드로 동작한다. 정류형태의 전류를 2차측에 공급하면, 낮은 주파수를 사용하는 전파정류 인버터가 고역률의 교류 파형으로 변환한다. 벅부스트에 탭인덕터를 적용함으로써 권선비에 따른 시비율을 조절할 수 있어 극단적인 승압시에도 벅부스트의 도통을 적절히 유지할 수 있다. 제안하는 인버터는 정상상태 연속모드(CCM)에서 PSIM을 통해 시뮬레이션을 하여 증명하였다.

  • PDF

Evaluation of a Buffered Multistage Interconnection Network (Buffered-MIN의 성능 분석)

  • 신태지;양명국
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.244-246
    • /
    • 1999
  • 본 논문에서는, multiple-buffered crossbar 스위치를 이용한 다층 연결 망의 성능 분석 모형을 제안하고, 스위치에 장착된 buffer의 개수 증가에 따른 성능 향상 추이를 분석하였다. Buffered 스위치 기법은 다층 연결 망 (Multistage Interconnection Network, MIN)의 내부의 데이터 충돌 문제를 효과적으로 해결할 수 있는 방법으로 알려져 있다. 제안된 성능 분석 모형은 먼저 네트웍 내부 임의 스위치 입력 단에 유입되는 데이터 패킷이 buffered 스위치 내부에서 전송되는 패턴을 확률적으로 분석하여 수립하였다. 분석 모형의 수학적 복잡도 절감을 위하여 확률식 유도 과정에 정상상태 확률 rosa(steady state probability)을 도입하였다. 제안한 모형은 스위치의 크기 및 스위치에 장착된 buffer의 수와 무관하게 확대 적용이 가능하다. 제안한 수학적 성능 분석 연구의 실효성 검증을 위하여 병행된 시뮬레이션 처리 결과는 상호 미세한 오차 범위 내에서 모형의 예측 데이터와 일치하는 결과를 보여 분석 모형의 타당성을 입증하였다. 2$\times$2 스위치로 구성된 8$\times$8 MIN을 대상으로 분석을 시행한 결과 스위치에 2~4개의 buffer를 장착했을 경우 unbuffer 스위치 경우와 비교하여 네트웍 정상상태 Throughout의 증가율이 높고 네트웍 Delay 또한 낮아져 효율적인 것으로 나타났다. 따라서 2~2 crossbar 스위치로 구성된 MIN의 경우 스위치에 장착된 buffer의 개수가 네 개 정도일 경우가 가격 대 성능비 면에서 가장 유리한 것으로 연구되었다.

  • PDF