• Title/Summary/Keyword: 정비부하 분석

Search Result 22, Processing Time 0.034 seconds

A SNA Based Loads Analysis of Naval Submarine Maintenance

  • Song, Ji-Seok;Kang, Dongsu;Lee, Sang-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.11
    • /
    • pp.201-210
    • /
    • 2020
  • Navy submarines are developed into complex weapons systems with various equipment, which directly leads to difficulties in submarine maintenance. In addition, the method of establishing a maintenance plan for submarines is limited in efficient maintenance because it relies on statistical access to the number of people, number of target ships, and consumption time. For efficient maintenance, it is necessary to derive and maintain major maintenance factors based on an understanding of the target. In this paper, the maintenance loads rate is defined as a key maintenance factor. the submarine maintenance data is analyzed using the SNA scheme to identify phenomena by focusing on the relationship between the analysis targets. Through this, maintenance loads characteristics that have not been previously revealed in quantitative analysis are derived to identify areas that the maintenance manager should focus on.

영광1,2,3,4호기 비상디젤발전기 종합신뢰도 분석

  • 김영호;최광희;정현종
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.115-121
    • /
    • 2000
  • 영광1,2,3,4호기 비상디젤발전기(EDG)의 신뢰도 수준을 파악하기 위하여 시험관리대장과 운전불능관리대장, 그리고 발전과장일지를 조사하여 신뢰도 및 이용불능도를 분석하였다. 신뢰도는 EDG의 유효시험 데이터를 이용하여 계산하는 유효 신뢰도와 무효시험까지 포함하여 계산하는 전체 신뢰도로 구분하였으며, 이용불능도는 EDG를 정비모드로 전환시키고 작업함으로서 이용불능을 유발하였던 정비 이용불능도, 그리고 유효시험 실패로 인하여 정비모드를 유발하는 경우에 잠재적 고장 시간까지 포함한 종합 이용불능도로 구분하였다. 분석 결과로서 영광1호기 EDG의 유효 신뢰도는 0.995, 2호기는 1.0으로 매우 높은 수준을 유지하고 있었으며, 이용불능도의 역인 이용가능도는 1호기 A계열 EDG는 0.978, B계열은 0.979, 2호기 A는 0.991, B는 0.976으로 높은 수준이었다. 3,4호기 EDG의 유효 신뢰도는 1,2호기와 마찬가지로 높은 수준이었으나, 전체 신뢰도는 텐덤형 디젤엔진이 갖는 근본적 부하불균형 문제 때문에 낮은 수준이었다. 따라서, 영광3,4호기 EDG의 신뢰도를 높이기 위해 많은 노력을 기울였으며, 이를 통해 EDG 신뢰도 개선에 도움이 된 것으로 분석되었다.

  • PDF

디젤발전기 엔진 상태신호 측정 및 분석 사례

  • Choe, Gwang-Hui;Lee, Sang-Guk;Lee, Byeong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.745-745
    • /
    • 2012
  • 원자력발전소에서 비상디젤발전기는 노심의 안전성을 지키는 매우 중요한 역할을 담당하고 있다. 이를 위해 디젤발전기는 신뢰성능 높게 유지하도록 규제요건이 마련되어 있다. 디젤발전기의 엔진 상태를 주기적으로 감시하고 평가하기 위해서는 엔진 상태 신호 분석 기술이 필요하다. 엔진 상태 신호 분석에는 연소분석과 진동 및 초음파 측정 및 분석기술이 중요한 비중을 차지한다. 연소 분석은 디젤 엔진의 개별 실린더에 대한 연소 성능에 대한 정보를 제공한다. 진동 및 초음파 분석은 이벤트 타이밍과 기계적 상태에 대한 정보를 알려준다. 이들 신호는 정상적인 부하로 운전하는 디젤엔진의 가동에 영향을 미치지 않고 수집할 수 있다. 엔진 상태 신호 분석을 이용하는 주요 동기는 전통적으로 장비 제작자의 권고에 따라 수행되는 분해-검사 유지 보수 프로그램을 일부 대체하고 예측정비를 통해 신뢰도를 유지하기 위함이다. 상태 진단정비는 엔진 상태 신호분석을 주로 이용하여 엔진의 신뢰도와 이용률을 증가시킬 수 있다. 본 논문에서는 국내외서 경험한 엔진상태신호 측정 및 분석 사례를 기술하였다.

  • PDF

Cause Analysis for Reduced Effect of Sewer Pipe Improvement Project Based On Investigation of Interceptor Sewers (차집관로의 조사 및 분석을 통한 하수관로정비 사업의 효과 감소 원인 분석)

  • Chae, Myungbyung;Bae, Younghye;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2018
  • Interceptor sewer is installed underground near to the river side mostly ofstate-owned land and the management efficiency of public sewage disposal facilities is decreasing as too much infiltration/inflow(I/I) and river flow to interceptor sewer are caused by broken or deteriorated sewer. This also affects the sewer pipeline project and decreases its efficiency. Therefore, the aim of this study is to investigate interceptor sewer which has influence on the reduction of the project effect. The investigation were performed for three study areas. The study includes the investigation of current condition of interceptor sewer(sewer extension, pipe diameter, pipe type, installed year, installed locations, etc), investigation of inside of sewer by CCTV accompanied by pumping and dredging works where required, investigation of inside of manholes by eyes, calculation of pollutant load using the results of investigation of flow quantity and quality. Multipoint investigations were simultaneously performed for flow quantity at confluence area and other investigations were also performed for flow quantity and BOD for interceptor sewer and comparison of pollutant load, investigation of infiltration/inflow(I/I) caused by deterioration of interceptor sewer. As the result of the study, a main reason for reduced effect of sewer pipe improvement project was analyzed as the low-density sewage and I/I in public seweage treatment Facility due to deteriorated and unmanaged interceptor sewers.

Analysis of water quality monitoring results during the rainfall period of Yeongju dam (영주댐 강우기 수질 모니터링 결과 분석)

  • Lee, Seungyoon;Shin, Cholong;Yi, Hye-suk;Chong, Sun-A
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.463-463
    • /
    • 2018
  • 우리나라의 공공용수역에서는 오염배출규제 및 하수도 정비에 의한 점오염원 부하량의 삭감에 의해 수질개선이 진행되어 왔다. 그러나, 비점오염원부하는 상대적으로 증가하는 경향에 있음에도 불구하고 그것을 실증하기 위한 강우시의 오염부하유출의 관측은 충분히 실시되지 않고 있다. 본 연구에서는 영주댐 유입하천을 대상으로 강우시 유입 오염부하량 파악 및 수질변동모의 예측을 위한 기초자료 획득을 위한 강우시 유입부하량 특성 및 수질영향이 분석되었다. 영주댐의 조사지점은 석표교, 멀내교의 총 2개 지점으로 본류인 내성천, 지류인 토일천에 각각 1곳씩 선정하였다. 유입수 샘플링은 자동모니터링 장치를 설치하여 채수하였고, 유랑조사는 교각에 설치된 자동수위측정기를 이용하여 측정하였다. 조사기간은 누적 강우량 133mm가 내린 2017년 7월 2일부터 5일간 실시하였다. 수질 시료 분석결과, 비강우시대비 COD 및 영양염류 부하량이 큰 폭으로 증가하는 것으로 나타났다. 토일천에서 채수된 시료의 경우 T-P는 비강우시 유입농도보다 최대 60배 높고, T-N은 비강우시에 비해 약 2.3배 높은 것으로 분석되었다. 강우유출 발생 시의 수질은 비강우시의 수질보다 COD 및 영양염류 부하량이 큰 폭으로 증가하였다. 비 강우시 유입되는 영양염류농도에 비해 강우시에는 강우강도에 비례하여 높은 농도의 인과 질소성분이 유입되고 있었고, 댐 저수량의 많은 부분이 강우시의 유입수량으로 채워지는 점을 고려할 때, 강우시 유입 수질이 댐 저수지 수질변화에 큰 영향을 주고 있을 것으로 판단된다. 영주댐 유역의 강우유출 특성은 강우유출이 시작 된 후, 수 시간 이내에 오염물질 농도가 급격히 증가하였고 유량의 증감속도와 유출량은 비례하였다. COD, 질소 계열 및 인 계열 물질의 유량과 비례한 증감을 확인하였다. 이를 통해 강우시 질소와 인의 유출이 강우량과 영향이 있음을 알 수 있었으나, 계절적인 유출 특성의 유무를 무시 할 수 없기 때문에 이에 대한 보다 상세한 조사 및 검토가 필요할 것으로 사료된다.

  • PDF

A Survey on the Co-Generation Load for Large Commercial Buildings (대형상업건물의 열병합발전 부하조사)

  • 한승호;권순우;정상원;정재혁
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 1998
  • Energy consumption statistics have been surveyed for 50 large commercial buildings with high energy consumption records in Seoul City. The buildings were classified into three different groups for data analysis: hospitals, hotels, and department stores/office buildings. The analysis was focused on identifying installed boiler and refrigerator data, energy consumption rates, and energy load distribution throughout the year. Refrigerating electricity was confirmed again to affect most on the formation of the summer electricity load peak as expected. Replacing the refrigerator electricity peak in the summer with co-generation in large commercial buildings. However, overall heat load distribution in a single building is still considered not large enough for economically feasible co-generation and thus joint co-generation for multiple neighboring buildings are preferred and the Electric Power Law and LNG pricing policy should be revised favorably for co-generation in advance.

  • PDF

The Effect of Sewer Pipe Retrofit on The Operation of Sewage Treatment Plant in Rural Area (농촌 지역의 하수관거 정비사업이 하수처리장 운영에 미치는 영향)

  • Kim, Seongjung;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • Recently, rural areas are rapidly developing, while existing infrastructure is inadequate and aging compared to developing rural areas. The most representative of these is the sewer system. Therefore, in this study, the rural area of Gyeonggi A city was selected as the study area and analyzed the effect of the sewer maintenance business on the operation of the sewage treatment plant. The analysis items were pollutant treatment efficiencies, the changes of inflow sewage amount, sewage concentration, influnet load, and C / N ratio by comparing before and after the development. As a result of the analysis, the sewage amount increased significantly after the development, and the sewage concentration increased after the development and the load of the sewage in the wastewater treatment plant also increased after the development. And improvement and management of inflow of unidentified water such as infiltration water and influent water in the sewage pipe was improved due to improvement of sewage pipe, which is considered to have affected the increase of C / N ratio and the improvement of TN and TP removal efficiency. The results of this study can be used as a representative example of the sewerage maintenance project in the rural area that positively influenced the operation of the sewage.

The Impact of Speech-To-Text-based Class on Learners' Cognitive Abilities

  • HyunMin Kang;SunKwan Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.287-293
    • /
    • 2024
  • This research studied the cognitive impact of classes using artificial intelligence on aviation technical school students. First, we developed a class consisting of a class based on traditional presentation materials and a class composed of speech-to-text (STT)-based artificial intelligence materials. A 133 students from an aviation education institution participated in two types of classes. We measured students' cognitive load and Mind Wandering test results before and after class, and conducted an achievement evaluation. As a result of the test analysis, we confirmed that extraneous cognitive load was reduced, content concentration increased, and achievement improved. In the future, we hope that AI-based STT classes will be widely used in schools that teach technology.

Analysis of Land Use and Pollutant Source Effect on Water Quality Characteristics of the Watershed (유역의 토지이용과 오염원 현황이 수질특성에 미치는 영향 분석)

  • Jung, Kwang-Wook;Jang, Jae-Ho;Kim, Hyung-Chul;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.41-51
    • /
    • 2006
  • The influence of land use and pollutant source on water quality was investigated using 3-yrs monitoring data major influent stream in Hwaong reservoir watershed. The seven water quality station (N1, N2, J1, J3, J4, E2, E3) were used analysis of land use and pollutant effect, and six water quality station (N3, N4, J2, J5, E1, E4) were used analysis of waster quality status. Water quality parameter were positively correlated with residential and forest, negatively with paddy and upland especially during dry period. During wet period, correlation between land use and water quality was less apparent. Population and livestock density was correlated well to water quality parameter than just number of population and livestock. The watersheds studied are mainly non-urban and their land uses are similar to typical watershed of other estuarine reservoirs, therefore, the correlation developed in this study might be helpful to manage other estuarine reservoir watersheds.

A Program of Water Quality Management for Agricultural Reservoirs by Trophic State (농업용 저수지의 부영양화와 수질관리방안)

  • Lee, Kwang-Sik;Yoon, Kyung-Sup;Kim, Ho-Il;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.166-171
    • /
    • 2003
  • A total of 498 agricultural reservoirs ranging from $164{\times}10^3\;m^3$ to $253{\times}10^6\;m^3$ in storage volume were investigated from 1990 to 2001 with respect to Chl-${\alpha}$, COD concentration and pollutant loading of BOD, TN, and TP. The lakes and reservoirs could be classified to 4 types using the relationships between the ratio of storage volume per water surface area(ST/WS) and Chl-${\alpha}$ concentration. It is recommended that the improvement of polluted lakes should be performed in the order of integrated consolidation type ${\rightarrow}$ watershed consolidation type ${\rightarrow}$ in-lake consolidation type ${\rightarrow}$ Management type and reservoir should be constructed to be over $5{\sim}6\;m$ in depth(ST/WS ratio) for preventing the eutrophication of agricultural reservoirs. We propose that water quality criteria for agricultural water is changed from less than 8 mg/L to less than 6 mg/L for safety value, $6{\sim}10\;mg/L$ for concern value, and more than 10 mg/L for countermeasure value in COD concentration, respectively.